top of page
Subscribe to Our Website

Thanks for submitting!

  • Facebook Social Icon
  • LinkedIn
  • Twitter

RO membranes

Osmoflux 8-inch (8040) spiral-wound reverse osmosis elements from Theway Membranes. Six brackish water types, from ultra-low energy to extra-high rejection, and seawater elements rated at 800 psi.

  • 8040 elements
  • Seven types
  • 300 to 440 ft² per element
  • Up to 99.85 % salt rejection
  • Brackish water and seawater

440 ft² in every type. Each Osmoflux type is also made as a 440 ft² (41 m²) element, for more permeate per pressure vessel in the same 8040 size.

Choose by type

Brackish water, ultra-low energy

For very low-pressure operation on low-TDS brackish feeds, to cut pump energy.

11,500 to 12,650 gpd
up to 99 % salt rejection at 125 psi

Brackish water, low energy

Rated at 150 psi, for low-pressure operation on low-TDS feeds.

9,000 to 9,900 gpd
up to 99.6 % salt rejection at 150 psi

Brackish water, standard

High flow and high rejection for brackish well, surface and UF-treated water.

9,500 to 12,650 gpd
up to 99.8 % salt rejection at 225 psi

Brackish water, high salt rejection

Extra-high rejection for low-TDS permeate on brackish feeds.

10,000 to 12,100 gpd
up to 99.7 % salt rejection at 225 psi

Brackish water, fouling resistant

For feeds with organic and biological load, such as treated effluent and surface water.

12,500 to 13,750 gpd
up to 99.7 % salt rejection at 225 psi

Brackish water, low fouling

Low-fouling spiral-wound construction for difficult brackish feeds.

10,000 to 11,000 gpd
up to 99.8 % salt rejection at 225 psi

Seawater

For seawater desalination and other high-TDS feeds.

6,000 to 15,070 gpd
up to 99.85 % salt rejection at 800 psi

Osmoflux range

  • Brackish water, ultra-low pressure
  • Brackish water, ultra-low energy
  • ULE TW 400: Area 400 ft² (37 m²); Permeate flow 11,500 gpd (43.5 m³/d); Salt rejection 99 %; Rated at 125 psi
  • ULE TW 440: Area 440 ft² (41 m²); Permeate flow 12,650 gpd (47.9 m³/d); Salt rejection 99 %; Rated at 125 psi
  • Brackish water, 150 to 225 psi
  • Brackish water, low energy
  • LE TW 400: Area 400 ft² (37 m²); Permeate flow 9,000 gpd (34.1 m³/d); Salt rejection 99.6 %; Rated at 150 psi
  • LE TW 440: Area 440 ft² (41 m²); Permeate flow 9,900 gpd (37.5 m³/d); Salt rejection 99.6 %; Rated at 150 psi; Datasheet Request
  • Brackish water, standard
  • BR TW 365: Area 365 ft² (34 m²); Permeate flow 9,500 gpd (36.0 m³/d); Salt rejection 99.5 %; Rated at 225 psi
  • BR TW 400: Area 400 ft² (37 m²); Permeate flow 11,500 gpd (43.5 m³/d); Salt rejection 99.8 %; Rated at 225 psi
  • BR TW 440: Area 440 ft² (41 m²); Permeate flow 12,650 gpd (47.9 m³/d); Salt rejection 99.8 %; Rated at 225 psi; Datasheet Request
  • Brackish water, high salt rejection
  • HSR TW 365: Area 365 ft² (34 m²); Permeate flow 10,000 gpd (37.9 m³/d); Salt rejection 99.7 %; Rated at 225 psi
  • HSR TW 400: Area 400 ft² (37 m²); Permeate flow 11,000 gpd (41.6 m³/d); Salt rejection 99.7 %; Rated at 225 psi
  • HSR TW 440: Area 440 ft² (41 m²); Permeate flow 12,100 gpd (45.8 m³/d); Salt rejection 99.7 %; Rated at 225 psi; Datasheet Request
  • Brackish water, fouling resistant
  • BFR TW 400: Area 400 ft² (37 m²); Permeate flow 12,500 gpd (47.3 m³/d); Salt rejection 99.7 %; Rated at 225 psi
  • BFR TW 440: Area 440 ft² (41 m²); Permeate flow 13,750 gpd (52.0 m³/d); Salt rejection 99.7 %; Rated at 225 psi; Datasheet Request
  • Brackish water, low fouling
  • LF TW 400: Area 400 ft² (37 m²); Permeate flow 10,000 gpd (37.9 m³/d); Salt rejection 99.8 %; Rated at 225 psi
  • LF TW 440: Area 440 ft² (41 m²); Permeate flow 11,000 gpd (41.6 m³/d); Salt rejection 99.8 %; Rated at 225 psi; Datasheet Request
  • Seawater, 800 psi
  • Seawater
  • MR TW 300: Area 300 ft² (28 m²); Permeate flow 6,000 gpd (22.7 m³/d); Salt rejection 99.1 %; Rated at 800 psi
  • MR TW 400: Area 400 ft² (37 m²); Permeate flow 9,000 gpd (34.1 m³/d); Salt rejection 99.8 %; Rated at 800 psi
  • MR TW 400 PRO: Area 400 ft² (37 m²); Permeate flow 7,000 gpd (26.5 m³/d); Salt rejection 99.8 %; Rated at 800 psi
  • MR TW 440: Area 440 ft² (41 m²); Permeate flow 9,900 gpd (37.5 m³/d); Salt rejection 99.8 %; Rated at 800 psi
  • MR TW 400 HB: Area 400 ft² (37 m²); Permeate flow 6,000 gpd (22.7 m³/d); Salt rejection 99.82 %; Rated at 800 psi
  • MR TW 400 ES: Area 400 ft² (37 m²); Permeate flow 13,700 gpd (51.9 m³/d); Salt rejection 99.8 %; Rated at 800 psi
  • MR TW 440 ES: Area 440 ft² (41 m²); Permeate flow 15,070 gpd (57.0 m³/d); Salt rejection 99.8 %; Rated at 800 psi
  • MR TW 440 PRO: Area 440 ft² (41 m²); Permeate flow 6,600 gpd (25.0 m³/d); Salt rejection 99.85 %; Rated at 800 psi

Flow and rejection at each model's test conditions, given on its datasheet. Permeate flow of an individual element may vary by ±15 %. The 440 ft² figures for BR, BFR, LE, LF and HSR are their 400 ft² ratings scaled for the larger area; ask for the datasheet. All elements are 8 in × 40 in: 1,016 mm long, 201 mm outside diameter, 29 mm permeate tube.

Specification note. Values are typical and for guidance only, not a guarantee of performance. Results depend on feed water quality, pretreatment, system design and operating conditions, and on installation, operation, cleaning and storage in line with the Theway operation manual. Limits apply only under those conditions; operating outside them can damage the membrane and may void the warranty. Specifications may change without notice as products are developed; please confirm current data with Theway before design or purchase. The warranty is governed solely by Theway's written terms of sale.

Fits the same pressure vessels as

  • ULE TW 400: Hydranautics ESPA4-LD; LG Chem BW 400 UES; Vontron XLP12-8040
  • ULE TW 440: LG Chem BW 440 UES
  • LE TW 400: DuPont FilmTec BW30XFRLE-400/34, Eco Pro-400; Hydranautics ESPA2, ESPA2-LD; Toray TMG20D-400; Veolia AK-400 H, AK8040F-400; LG Chem BW 400 ES, BW 400 ES L
  • LE TW 440: DuPont FilmTec BW30HRLE-440, Eco Pro-440; Hydranautics ESPA2-LD MAX; Toray TMG20D-440; Veolia AK-440 H; LG Chem BW 440 ES
  • BR TW 365: DuPont FilmTec BW30 PRO-365; Hydranautics CPA2; Toray TM720-370; Veolia AG8040F
  • BR TW 400: DuPont FilmTec BW30-400, BW30-400/34i; Hydranautics CPA3-LD; Toray TM720D-400, TM720-400; Veolia AG8040F-400; LG Chem BW 400 R, BW 400 R Dura; Vontron LP22-8040
  • BR TW 440: DuPont FilmTec BW30HR-440; Hydranautics CPA5 MAX; Toray TM720-440; Veolia AG-440 H; LG Chem BW 440 R, BW 440 R Dura; Vontron LP22-8040-440
  • HSR TW 365: DuPont FilmTec BW30 PRO-365; Hydranautics CPA2; Toray TM720-370; Veolia AG8040F
  • HSR TW 400: DuPont FilmTec BW30XHR PRO-400/34; Hydranautics CPA3-LD; Toray TM720D-400; Veolia AG-400 H; LG Chem BW 400 R G2
  • HSR TW 440: DuPont FilmTec BW30XHR PRO-440; Hydranautics CPA5 MAX; Toray TM720-440; Veolia AG-440 H; LG Chem BW 440 R G2
  • BFR TW 400: DuPont FilmTec Fortilife CR200; Hydranautics CPA7-LD, LFC3-LD; Toray TML20D-400; Veolia AG-400 LF,34; LG Chem BW 400 AFR, BW 400 AFR G2
  • BFR TW 440: Hydranautics CPA7 MAX
  • LF TW 400: DuPont FilmTec BW30XFR-400/34i, Fortilife CR100; Hydranautics CPA7-LD, LFC3-LD; Toray TML20D-400; Veolia AG-400 LF,34
  • LF TW 440: Hydranautics CPA7 MAX
  • MR TW 300: DuPont FilmTec SW30-8040, SW30HR-380; Hydranautics SWC3; Toray TM820M-370; Veolia AD-365
  • MR TW 400: DuPont FilmTec SW30XLE-400; Hydranautics SWC5-LD; Toray TM820V-400; Veolia AE-400,34; LG Chem SW 400 R, SW 400 R G2
  • MR TW 400 PRO: DuPont FilmTec SW30HRLE-400; Hydranautics SWC3+, SWC4+; Toray TM820M-400; Veolia AD-400,34; LG Chem SW 400 SR, SW 400 SR G2
  • MR TW 440: DuPont FilmTec SW30XLE-440; Hydranautics SWC5 MAX; Toray TM820V-440; Veolia AD-440; LG Chem SW 440 R, SW 440 R G2
  • MR TW 400 HB: DuPont FilmTec SW30XHR-400
  • MR TW 400 ES: LG Chem SW 400 ES
  • MR TW 440 ES: LG Chem SW 440 ES
  • MR TW 440 PRO: LG Chem SW 440 SR

Brand and model names belong to their owners and are used only to identify the elements an Osmoflux element can replace. Check operating conditions against the Osmoflux datasheet before replacing elements.

Where Osmoflux elements are used

  • Power plants
  • Steel
  • Fertiliser
  • Oil and gas
  • Food and beverages
  • Dairy
  • Pharmaceuticals and nutraceuticals
  • Agriculture and aquaculture
  • Hospitals
  • Airports
  • Universities
  • Shopping centres
  • Laboratories

For RO feed, Theway Stream UF modules give a stable, low-SDI feed, so RO elements foul less and need less cleaning.

Support from Theway

  • Rack sizing and the number of elements for your flow and recovery
  • P&ID review, skid drawing review, and pump and compressor selection
  • Remote support at start-up; PLC, SCADA and HMI support for larger projects
  • Safe export packing, and air-conditioned membrane storage containers on request

Questions buyers ask

Osmoflux elements are standard 8-inch (8040) elements, 1,016 mm long with a 201 mm outside diameter and a 29 mm permeate tube, supplied with brine seal, interconnector and O-rings. Check your feed pressure and water against the datasheet of the model you choose.

It puts 440 ft² of membrane in the same 8040 element, so each pressure vessel makes more permeate at the same flux. Ask for the 440 ft² datasheet of the type you need.

Brackish water types are rated at 1,500 or 2,000 ppm NaCl and up to 225 psi; seawater types at 32,000 ppm NaCl and 800 psi; all at 25 °C. Each datasheet gives the full test conditions.

Send your feed water analysis, flow, recovery and the elements now in service through Send Enquiry or to mail@thewaymembranes.com. Prices are quoted per project.

Need RO elements?

Send these and our engineers will recommend the type, size and number of elements:

  • Feed water analysis
  • Flow and recovery
  • The elements now in service
bottom of page