top of page
Theway Membranes Img.JPG
UF BACKGROUND (1).png

UltraFiltration Membranes Stream series

Ultrafiltration (UF) is a pressure-driven membrane based specification process to remove suspended solids, bacteria, viruses, endotoxins and other pathogens to produce water with very high purity and low silt density.

Merits of Theway UF Membranes

​

  • Increased flux

  • Increased Hydrophilicity

  • Exceptional service life

  • Higher resistance to fouling

  • Higher resistance to scaling

  • Lower pressure requirement

  • Wide range of MWCOs

  • Superior mechanical strength

  • Finer and sharper pore size distribution

  • Premium chemical resistance

Why Theway Membranes

​

Membrane Specification

Membrane polymer

MWCO

PVDF/PES/PS

100/67/50/20/10 KDa

Backwash flux

100-300 L/m²/hr

Size of the fibre

1.2 mm ODx 0.6mm ID

MOC of housing

uPVC

Operating pH

1-13

Operating temperature

45 °c

Backwash pressure

2 bar max

Filtrate flux

50-100 L/m²/hr

Trans-membrane pressure

2 bar max

Flow

Out-In

Operating pressure

< 3 bar

Operating mode

Cross flow

STREAM SERIES

Subscribe to Our Website

Thanks for submitting!

  • Facebook Social Icon
  • LinkedIn
  • Twitter

Ultrafiltration Membranes Stream series

Stream modules are Theway's own hollow fibre UF membranes. Ten standard sizes cover 8 to 145 m² of membrane per module, in 1100 mm and 1650 mm lengths, with out-in flow and 1.2 mm OD fibre in PES or PVDF.

Stream UF range

  • 1,100 mm long
  • TW 90/1100: Length 1,100 mm; Membrane area 8 m²
  • TW 160/1100: Length 1,100 mm; Membrane area 20 m²
  • TW 200/1100: Length 1,100 mm; Membrane area 40 m²
  • TW 250/1100: Length 1,100 mm; Membrane area 55 m²
  • TW 315/1100: Length 1,100 mm; Membrane area 95 m²
  • 1,650 mm long
  • TW 90/1650: Length 1,650 mm; Membrane area 12 m²
  • TW 160/1650: Length 1,650 mm; Membrane area 35 m²
  • TW 200/1650: Length 1,650 mm; Membrane area 60 m²
  • TW 250/1650: Length 1,650 mm; Membrane area 80 m²
  • TW 315/1650: Length 1,650 mm; Membrane area 145 m²

The model number gives the module diameter and length in mm. Thumbnails show the relative diameter and length. Each model page and datasheet gives the drawings.

Stream modules in service

Plants running Theway modules today. Customer names are not published.

Specifications

  • Type: Hollow fibre
  • Membrane material: PES / PVDF
  • MWCO: 100 kDa standard; 67, 50, 20 and 10 kDa options
  • Fibre size: 1.2 mm OD × 0.6 mm ID
  • Flow: Out-in
  • Housing: PVC
  • Potting: Proprietary epoxy
  • End caps: PVC / PP
  • Membrane area: 8 to 145 m² by model
  • Operating mode: Cross flow or dead end
  • Maximum feed pressure: 3 kg/cm² (set 1 to 1.2 bar)
  • Maximum transmembrane pressure: 1 kg/cm²
  • Maximum backwash pressure: 2 kg/cm²
  • Operating pH: 2 to 11
  • Cleaning pH: 1 to 13
  • Operating temperature: 20 to 45 °C
  • Cleaning temperature, maximum: 40 °C
  • Chlorine for cleaning: Up to 200 ppm at pH 10 or above
  • Feed flux: 20 to 100 L/m²·h
  • Backwash flux: 40 to 150 L/m²·h

Filtration 15 to 60 min, backwash 20 to 60 s, flushing 20 to 60 s. Pressures are limits, not set points; limits fall as temperature rises. Cleaning limits for every series: membrane cleaning limits.

Specification note. Values are typical and for guidance only, not a guarantee of performance. Results depend on feed water quality, pretreatment, system design and operating conditions, and on installation, operation, cleaning and storage in line with the Theway operation manual. Specifications may change without notice; confirm current data with Theway before design or purchase.

Merits of Theway UF membranes

  • Increased flux
  • Increased hydrophilicity
  • Exceptional service life
  • Higher resistance to fouling
  • Higher resistance to scaling
  • Lower pressure requirement
  • Wide range of MWCOs
  • Superior mechanical strength
  • Finer and sharper pore size distribution
  • Premium chemical resistance

Why Theway membranes

Where Stream modules are used

Pre-treatment ahead of seawater and brackish RO, sewage and effluent recycling, drinking water, and process water in paper, food and beverage, textile, tannery, power, oil and gas, sugar and chemical plants.

Replacing another brand's UF module?

Theway makes direct retrofits that fit the housings, ports and racks of Pentair X-Flow, DuPont, Hydranautics, Koch and Suez modules, so a plant can change membranes without changing pipework.

Need 0.1 µm microfiltration? Stream MF is the same module in every size with a 0.1 µm membrane.

Questions buyers ask

The fibre is made in PVDF, PES or PS with MWCO options of 100, 67, 50, 20 and 10 kDa. The standard model datasheets list 100 kDa.

Set the feed at 1 to 1.2 bar; the 3 bar figure on the datasheet is a limit, not a set point. Datasheet feed flux is 20 to 100 L/m²·h, and the design value depends on your feed water. The UF sizing calculator gives a first estimate.

Both work. Cross flow suits feed with more suspended solids and longer runs between cleans; dead end suits cleaner feed and uses less energy.

Send your feed water analysis, flow and application through Send Enquiry or to mail@thewaymembranes.com, and our engineers will size the modules.

brochure

Need UF modules?

Send these and our engineers will recommend the model and number of modules:

  • Water analysis
  • Flow and application
  • The modules now in service
bottom of page