top of page

Hydranautics HYDRAcap MAX modules replaced with Puran Max at a refinery in North India

Jan 31
2 min read

Updated: 2 hours ago

At a glance: a refinery in North India replaced the Hydranautics HYDRAcap MAX ultrafiltration modules (105 m², TIPS fibre) in its DM plant pretreatment with Theway Puran Max modules in 2025. The system treats about 4 MLD of refinery effluent ahead of RO, with filtrate turbidity below 1 NTU and SDI below 3.

Theway Puran Max UF modules replacing HYDRAcap MAX at a refinery
Puran Max modules in the UF skid

The installation

Item

Detail

Plant

Petroleum refinery

Region

North India

Application

Pretreatment to RO in the DM plant, about 4 MLD

Feed water

Treated refinery effluent, turbidity up to 100 NTU, TSS 150 to 200 ppm, SDI above 6

Modules replaced

Hydranautics HYDRAcap MAX, 105 m², TIPS fibre

Theway supply

Puran Max UF modules

Commissioned

2025

Results

  • Filtrate turbidity below 1 NTU

  • Filtrate SDI below 3

  • No module replaced since commissioning

These figures held over the first six months reported, with feed turbidity up to 100 NTU.

Theway UF modules on a refinery UF skid beside the reject line
The skid from the reject header side
Theway Puran Max modules at a refinery
Puran Max modules in service

How a direct replacement fits

A Theway direct replacement module is made to the dimensions and connections of the module it replaces, so it goes into the existing rack, couplings and pipework. The plant keeps its frames, valves and controls; only the modules change.

Every HYDRAcap and HYDRAcap MAX model and its Theway replacement is listed in Replacing Hydranautics HYDRAcap UF modules.

Send the make and model of your modules, how many there are and your feed water analysis to mail@thewaymembranes.com, or find your module in the retrofit finder to see the Theway equivalent and its datasheet.

Customer names are not published. Other plants running Theway membranes are listed on our Milestones page.

Related: see the direct-retrofit UF range and size your plant in Theway Compass.

Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.