Replacing Hydranautics HYDRAcap UF modules: Puran and Puran Max
Updated: 1 day ago
At a glance: Theway's Puran modules replace Hydranautics HYDRAcap 40A and 60A, and Puran Max modules replace HYDRAcap MAX 40, 60 and 80. All five are equivalence level 8, Theway's closest match: operating philosophy, form, ports, dimensions, membrane material, MWCO, fibre and performance. They fit the existing housings and racks and run on the existing control sequence.

A HYDRAcap MAX replacement in service

A refinery in North India replaced its HYDRAcap MAX modules (105 m², TIPS fibre) with Theway Puran Max in 2025. It treats about 4 MLD of refinery effluent ahead of RO with filtrate turbidity below 1 NTU and SDI below 3. Photos and details.
Model cross-reference
Existing module | Theway retrofit | Area (m²) | MWCO | Level |
|---|---|---|---|---|
HYDRAcap 40A | 30 | 100 kDa | 8 | |
HYDRAcap 60A | 46 | 100 kDa | 8 | |
HYDRAcap MAX 40 | 52 | 150 kDa | 8 | |
HYDRAcap MAX 60 | 78 | 150 kDa | 8 | |
HYDRAcap MAX 80 | 105 | 150 kDa | 8 |
Brand and model names belong to their owners and are used here only to identify the modules each Theway retrofit replaces.
Puran and Puran Max data
Parameter | Value |
|---|---|
Membrane | PES (Puran) or TIPS PVDF (Puran Max), hollow fibre |
Fibre | 1.2 mm OD × 0.6 mm ID |
Housing | uPVC, PVC or PP caps, proprietary epoxy potting |
Feed pressure | 3 kg/cm² maximum |
Transmembrane pressure | 1 kg/cm² maximum |
Backwash pressure | 2 kg/cm² maximum |
pH, cleaning | 1 to 13 |
Temperature | 20 to 45 °C (Puran); 20 to 50 °C (Puran Max) |
Feed flux | 20 to 100 L/m²·h |
Backwash flux | 40 to 150 L/m²·h |
In service
Puran Max modules treat refinery effluent ahead of RO at a refinery in North India, where feed quality varies widely and carries oil traces, COD and suspended solids.
Changeover steps
Note the model and quantity from the nameplates and photograph the module ends and rack.
Send recent operating data and cleaning history so we can see why the old modules are being replaced.
Replace a full train at a time, so every module in the train starts with the same permeability.
Inspect and replace worn couplings and O-rings.
Flush the preservative to drain before sending filtrate to RO. See commissioning new UF modules.
Record flow, TMP and temperature on day one as the baseline.
Checklist
Model and quantity confirmed from nameplates
Photos of ports and rack sent
Cycle settings and chemicals checked against datasheet limits
Spare seals on site
Drain route for flush water
Baseline readings planned
Questions buyers ask
Will the control sequence need changing?
Level 8 includes operating philosophy, so the existing sequence normally stays. We check the settings with you before start-up.
Why is Puran Max rated at 150 kDa?
The MWCO matches the duty of the modules it replaces and gives higher permeability on water treatment duties.
Can I order a few modules to replace failed ones?
Yes, but within one train we advise replacing all modules together for even flow sharing.
Do you hold stock?
Ask for lead time on your models when you enquire.
Retrofit guides by maker
Get a retrofit quotation
Send model, quantity and photos through Send Enquiry or to mail@thewaymembranes.com. All Theway retrofits are listed on the direct retrofit page.
Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.