Airlift tubular MBR for high-strength industrial effluent
The short answer
Airlift MBR is a side-stream MBR that uses air, not a big pump, to move sludge through the tubes. Vertical tubular modules sit beside the bioreactor. Air injected at the bottom of each module lifts the sludge upward as a two-phase flow.
It suits high-COD, hot or difficult industrial effluent. Pharma, chemical, food and beverage effluents with COD in the thousands of mg/L, temperatures of 35 to 45 °C, or sludge that settles poorly are the usual cases.
It sits between the other two MBR types. Typical flux is 30 to 60 L/m²h, against 10 to 25 L/m²h for submerged MBR on industrial duty. Typical membrane energy is 0.3 to 0.7 kWh/m³ of permeate, against 2 to 6 kWh/m³ for a pumped side-stream loop.
The membranes are outside the biology. You can clean, inspect or replace a module without draining or entering a tank, and the bioreactor can be covered, deep or heated.
Theway's module for this duty is Tubeflux T5-830 AL: 5.2 mm tubes in an 8-inch shell, 3 m long. Check the datasheet for area, pressure, temperature and cleaning limits.
Submerged, pumped side-stream and airlift MBR
All three use a membrane in place of a clarifier. They differ in where the membrane sits and how its surface is kept clean.
Submerged MBR places hollow fibre or flat sheet modules in the sludge, in the bioreactor or in a separate membrane tank. Coarse-bubble scour air keeps the cake under control, and a suction pump draws permeate at low transmembrane pressure (TMP). It is the lowest-energy option for large municipal plants. See membrane bioreactors and Theway's Surge MBR range.
Pumped side-stream MBR recirculates sludge at high velocity (typically 2 to 5 m/s) through horizontal tubular modules. It tolerates very high MLSS and difficult sludge but spends a lot of energy on pumping.
Airlift side-stream MBR mounts tubular modules vertically. A low-head pump feeds sludge to the bottom of each module and air is injected at the same point. The rising air and sludge mixture scours the inside of the tubes at a much lower liquid velocity than a pumped loop, so the energy falls sharply. Concentrate returns to the tank by gravity, and a permeate pump draws filtrate at low TMP.
Parameter (typical) | Submerged MBR | Pumped side-stream | Airlift side-stream |
|---|---|---|---|
Membrane type | Hollow fibre or flat sheet | Tubular, horizontal | Tubular, vertical |
MLSS in contact with membrane | 8 to 12 g/L | 10 to 25 g/L | 8 to 15 g/L |
Liquid velocity in channel | Not applicable | 2 to 5 m/s | 0.3 to 1 m/s, plus air |
Flux, industrial duty | 10 to 25 L/m²h | 50 to 120 L/m²h | 30 to 60 L/m²h |
TMP | 0.1 to 0.5 bar | 1 to 4 bar | 0.1 to 0.5 bar |
Membrane energy | 0.3 to 0.8 kWh/m³ | 2 to 6 kWh/m³ | 0.3 to 0.7 kWh/m³ |
These are typical ranges for comparison, not design values. The right number for any plant depends on the sludge.
Why airlift suits high-strength industrial effluent
High-strength effluent is hard on a submerged membrane. Long sludge ages and high organic loads create sludge rich in soluble microbial products and extracellular polymers. These foul hollow fibres quickly, so submerged plants on these duties often run at the bottom of their flux range, with frequent cleaning.
Airlift tubular modules handle this better for five reasons:
Open channels. A 5.2 mm tube has no fibre bundle to sludge up and no spacer to block. Cross-flow and air scour act on every square metre of membrane.
Higher sustainable flux. The two-phase flow gives strong shear at the wall, so flux is typically two to three times that of a submerged membrane on the same sludge.
Membranes isolated from the tank. The bioreactor can be deep, covered for odour or solvent vapour, cooled or heated. Biological aeration can be designed for oxygen demand alone, not for membrane scour.
Cleaning in place. A module or a bank is isolated and cleaned with heated chemicals while the others run. Nobody has to lift cassettes out of sludge.
Warm effluent helps. Many process effluents arrive at 35 to 45 °C. Lower viscosity raises flux, as long as the temperature stays within the module limit on the datasheet.
Airlift is not always the answer. For very viscous sludge, MLSS above about 15 g/L or fibrous solids, a pumped loop with larger tubes, such as the Tubeflux T8 range, is usually safer. For large, dilute municipal flows, submerged MBR normally costs less.
Layout and energy
A typical airlift skid has:
Fine screening ahead of the bioreactor. With 5 mm tubes, fibres and hair must be removed. Take the screen size from the Tubeflux datasheet.
Bioreactor with its own fine-bubble aeration, sized for the COD and nitrogen load.
Feed pump delivering sludge to the bottom of the vertical modules at low head.
Air injection at the base of each module, from a small blower.
Permeate pump drawing filtrate at low TMP, with a permeate tank for backflush.
CIP tank with heating, sized to fill one bank of modules and its pipework.
The membrane energy is the feed pump plus the module air plus the permeate pump. On high-strength effluent, the biological aeration is usually the bigger number, and that is where the choice of MBR type shows.
Worked example: 200 m³/d of high-COD process effluent
Basis (illustrative): 200 m³/d (8.3 m³/h) of permeate. Feed COD 8,000 mg/L, 95 % removed. Oxygen demand about 0.6 kg O₂ per kg of COD removed at a long sludge age, giving about 910 kg O₂/d. Fine-bubble aeration at about 1.75 kg O₂ per kWh in sludge. Fluxes and membrane energies are typical values taken from the table above, not test results.
Item | Submerged MBR | Pumped side-stream | Airlift side-stream |
|---|---|---|---|
Design flux (typical, assumed) | 10 L/m²h | 70 L/m²h | 35 L/m²h |
Membrane area | 830 m² | 120 m² | 240 m² |
Membrane energy (typical, assumed) | 0.6 kWh/m³ | 4.0 kWh/m³ | 0.5 kWh/m³ |
Membrane energy per day | 120 kWh/d | 800 kWh/d | 100 kWh/d |
Biological aeration per day | 520 kWh/d | 520 kWh/d | 520 kWh/d |
Total, membranes plus aeration | 640 kWh/d | 1,320 kWh/d | 620 kWh/d |
Total per m³ of permeate | 3.2 kWh/m³ | 6.6 kWh/m³ | 3.1 kWh/m³ |
On these assumptions, airlift uses about the same energy as a submerged plant with less than a third of the membrane area. The pumped loop uses the least membrane but roughly doubles the energy. Treat the table as a way of framing the choice, not as a result.
Use the UF sizing calculator for the area check and Theway Compass to project any RO stage that follows the MBR.
What to do
Characterise the effluent over a production cycle. Measure COD, BOD, TSS, oil and grease, temperature, pH, ammonia, salinity and solvents. Batch plants change by the shift.
Check biotreatability first. Toxic or inhibitory streams may need segregation or pretreatment before any MBR.
Choose the MBR type with the comparison table: submerged for large, dilute flows; airlift for high-strength or warm effluent at moderate MLSS; pumped side-stream for viscous or fibrous sludge.
Size on a conservative flux. Use the lower half of the typical range unless pilot data support more, and check one bank out of service for cleaning.
Screen properly. Fibres and grit are the main threat to small-bore tubes.
Plan cleaning from day one. A heated CIP tank, a permeate flush and permeability logging. Check limits on the membrane cleaning limits page.
Pilot industrial effluent. A few weeks on site settles flux, cleaning frequency and sludge behaviour. Send us an enquiry.
Questions engineers ask
Can airlift modules be added to an existing activated sludge plant?
Often, yes. The modules replace the clarifier and sit on a skid beside the aeration tank. Check that the tank can be run at the higher MLSS and that the blower can meet the extra oxygen demand.
What MLSS should an airlift MBR run at?
Typically 8 to 15 g/L at the membrane. Higher concentrations raise viscosity and cut flux. If the process needs more, a pumped side-stream loop is usually a better fit.
How are the modules cleaned?
A short backflush with permeate is part of the normal cycle. Chemical cleaning isolates a bank and circulates hypochlorite for organics and biofilm, then acid for scale and metals, warmed where the datasheet allows.
Is airlift MBR permeate good enough to feed RO?
Usually. MBR permeate is free of suspended solids and bacteria, so it is a common RO feed for reuse. Organics and salinity still need checking. See RO membranes.
Can the membranes handle solvents or very hot effluent?
Only within the module limits. Check the Tubeflux datasheet for temperature, pH and chemical compatibility. Where solvents or temperature exceed polymer limits, ceramic membranes may be an option.
Specification note: The figures in this article are typical engineering values and an illustrative worked example, not measurements from any plant. Flux, energy, MLSS and cleaning frequency depend on the effluent and the sludge, and must be confirmed by design and, for industrial effluent, a pilot. Compass results are estimates for information only and are not a performance guarantee. See the product and datasheet disclaimer.