The short answer

  • Normalise before you worry. Permeate conductivity rises with feed salinity and temperature, and when flux falls. Normalised salt passage removes those effects. If it is flat, the membranes are fine.

  • Find where it comes from. Read the permeate conductivity of every stage and every vessel. A general rise points to the membranes or the operating conditions. One bad vessel points to a leak or a damaged element.

  • Probe the bad vessel. A sharp spike at one joint means an O-ring or interconnector leak. A high reading along one element means that element is damaged.

  • Read the other signals with it. Salt passage up with normalised flow up suggests oxidation or abrasion. Salt passage up with flow down and pressure drop up in the last stage suggests scaling.

  • Fix the cause, then the part. Seals are quick to replace and scaled elements often recover with an acid clean. Oxidised elements do not recover.

Normalise first: real salt passage or just conditions?

Raw permeate conductivity is a poor guide on its own. Three things move it without any change in the membranes:

  • Feed salinity. Salt passage is a percentage, so more salt in the feed means more salt in the permeate.

  • Temperature. Salt moves through the membrane faster in warm water. A typical figure is about 3 % more salt passage per °C. A summer rise of 8 °C can lift permeate conductivity by about a quarter on its own.

  • Flux. Salt flux through the membrane is nearly independent of pressure, but water flux is not. If the train runs at lower flux, for example during turndown, less water dilutes the same salt and permeate conductivity rises.

Normalised salt passage corrects for all three, against the average feed-concentrate conductivity at start-up temperature and flux. Trend it stage by stage. See the RO and UF normalisation guide for the method and the inputs.

Check the instruments too. A drifting or badly compensated conductivity meter can create or hide a trend.

Where the extra salt comes from

One vessel high, others normal. This is mechanical in most cases: a cut, rolled or missing O-ring on an interconnector, a cracked interconnector, a damaged end adapter O-ring, or one element with a damaged glue line. These leaks let feed water into the permeate tube.

Lead elements worst, normalised flow up. This is the sign of oxidation. Polyamide membranes are damaged by free chlorine and other oxidants, and the lead elements see them first. Salt passage and permeate flow rise together. Abrasion from sharp particles gives a similar pattern.

Last stage worst, normalised flow down, pressure drop up. This is the sign of scaling. Calcium carbonate, calcium sulphate, barium sulphate or silica deposit where the concentrate is strongest. The scale raises concentration polarisation at the membrane surface, so salt passage rises in the tail elements.

General slow rise across the train. This is ageing, or fouling that has not been cleaned. A clean separates the two. See when to clean RO and UF with normalised data.

Brine seal faults show differently. A missing or reversed brine seal lets feed bypass the element, so cross-flow falls and fouling and scaling come sooner. It rarely shows as a probing spike, so check brine seal direction whenever elements are loaded.

How to probe a pressure vessel

Probing finds a leak inside a vessel. You need small-bore flexible tube longer than the vessel, a sealing adapter for the permeate port, and a conductivity meter.

  1. Run the train at its normal flow and recovery, with steady conditions.

  2. Fit the probe adapter to the permeate port and push the tube to the far end of the permeate tube.

  3. Let a small sample flow, flush for one to two minutes, then read the conductivity.

  4. Withdraw the tube in steps of typically 15 to 20 cm, reading at each step. Mark the element joints on the tube first; an 8040 element is about 1,016 mm long.

  5. Plot conductivity against position.

Read the profile like this:

  • A smooth, gentle rise along the vessel is normal. Downstream elements see more concentrated feed.

  • A sharp spike or step at a joint means an O-ring or interconnector leak at that joint.

  • A spike at the end of the vessel means an end adapter or thrust ring seal leak.

  • High readings along the full length of one element mean that element is damaged.

The exact shape depends on which end the permeate leaves the vessel. Look for the sharp change rather than the absolute value.

Worked example

Basis: an illustrative two-stage brackish RO train with a 4:2 array of six-element vessels, 36 Osmoflux 8040 elements in all, at 75 % recovery and constant permeate flow. Average feed-concentrate conductivity is taken as 1.85 times feed conductivity at this recovery. Salt passage is shown as permeate over average feed-concentrate conductivity, then corrected to 22 °C at a typical 3 % per °C.


Start-up

Case A

Case B

Feed conductivity (µS/cm)

2,000

2,400

2,400

Feed temperature (°C)

22

30

30

Permeate conductivity (µS/cm)

40

62

85

Salt passage, raw (%)

1.08

1.40

1.91

Normalised salt passage at 22 °C (%)

1.08

1.10

1.51

Change from start-up

–

+2 %

+40 %

Case A looks alarming, but normalised salt passage is flat. Warmer, saltier feed explains it.

Case B is a real rise of 40 %. At Case B conditions, the expected permeate is about 43 µS/cm from stage 1 vessels and 99 µS/cm from stage 2. The per-vessel readings were:

Vessel

1-1

1-2

1-3

1-4

2-1

2-2

Permeate (µS/cm)

44

45

118

44

128

130

That is two faults. Vessel 1-3 is a single-vessel fault. Both stage 2 vessels are about 30 % high, and stage 2 pressure drop was up 25 % with normalised flow down 8 %: scaling in the tail.

The probe profile of vessel 1-3, in µS/cm, at the element centres (E) and joints (J):

E1

J1/2

E2

J2/3

E3

J3/4

E4

J4/5

E5

J5/6

E6

30

31

33

34

37

260

48

47

52

55

60

The spike at joint 3/4 marks an interconnector leak. On opening the vessel, an O-ring there was found rolled. After new O-rings in vessel 1-3 and an acid clean of stage 2, vessel 1-3 read 45 µS/cm, stage 2 read 104 µS/cm and the train read 64 µS/cm. Normalised salt passage came back to about 1.14 %, 5 % above start-up.

Damage or scale: what to replace

  • O-rings and interconnectors. Replace every O-ring in the vessel when one is faulty. Lubricate with water or glycerine only, never petroleum grease.

  • Scaled tail elements. Clean first with a low-pH cleaner, within the supplier's limits. See membrane cleaning limits. Then fix the cause: recovery, antiscalant dose or feed pH. Replace only the elements that do not recover.

  • Oxidised elements. The damage is permanent. Fix the oxidant source first, such as a sodium bisulphite dosing failure, then replace the damaged elements, usually the lead positions.

  • Telescoped elements. Replace them, and check for pressure surges, missing anti-telescoping devices or flow above the element limit.

What to do

  1. Check that feed and permeate conductivity meters are calibrated and compensated to 25 °C.

  2. Calculate normalised salt passage per stage and compare it with the start-up baseline.

  3. If it is flat, the rise is temperature, feed salinity or flux. Record it and carry on.

  4. If it is rising, read permeate conductivity from every vessel.

  5. Probe any vessel that is out of line with the others in its stage.

  6. Replace leaking O-rings, interconnectors or end adapter seals, and recheck the vessel.

  7. For a stage-wide rise, look at normalised flow and pressure drop. Clean for scale or fouling, or trace the oxidant source.

  8. Replace elements only where cleaning does not restore salt passage. Compare the new data with the expected performance from Theway Compass.

Questions engineers ask

How much rise in normalised salt passage should trigger action?

A common trigger is a rise of 10 to 15 % above the baseline. Act sooner if permeate is close to its specification. Raw conductivity on its own is not a trigger.

Can I probe a vessel while the train is running?

Yes, probing is done in normal operation. Follow your site's rules for work on pressurised equipment.

Why is salt passage higher at low flux?

Salt flux stays almost the same while water flux falls, so the permeate is less diluted. Keep flux within the design range when you compare data.

How can I tell oxidation from fouling?

Oxidation raises normalised permeate flow and salt passage together, and cleaning does not reverse it. Fouling lowers flow, raises pressure drop, and largely recovers after a clean.

Which Theway products relate to this?

Osmoflux RO elements for replacement, Armaflux pressure vessels for new trains, and O-ring and seal kits for repairs. Send your normalised data through our enquiry form for a review.

Specification note: The figures in this article are typical values and an illustrative example, built to show the method. They are not measurements from any plant. Follow the membrane supplier's handling, cleaning and loading instructions for your elements. This article is not a performance guarantee. See the product and datasheet disclaimer.

Comments


bottom of page