top of page

Sulphate-removal NF for oilfield injection water

1 hour ago
6 min read

The short answer

Seawater injected for pressure support carries roughly 2,700 to 3,500 mg/L of sulphate. When it meets formation water rich in barium and strontium, barium and strontium sulphate scale forms in the near-wellbore rock, the producing wells and the topside equipment. Sulphate also feeds sulphate-reducing bacteria, which turn it into hydrogen sulphide and sour the reservoir.

A sulphate-removal unit (SRU) uses nanofiltration (NF) to take the sulphate down to a typical 20 to 50 mg/L while letting most of the sodium chloride through. Typical figures:

  • Sulphate rejection: about 99 to 99.8 % across the unit.

  • Recovery: about 70 to 75 %, usually in two stages.

  • Feed pressure: typically 20 to 30 bar, far below seawater RO.

  • Pretreatment: UF or well-run media filtration, cartridge filters and full dechlorination.

The design target comes from the reservoir, not the membrane: the barium and strontium in the formation water, the scale inhibitor programme, and the souring risk.

Why sulphate in injection water is a problem

Barium and strontium sulphate scale. Barium sulphate is one of the least soluble common minerals, with a solubility of only a few mg/L at reservoir conditions. Formation water in many fields carries tens to hundreds of mg/L of barium, and some carry more; strontium is often present at hundreds of mg/L. Untreated seawater mixing with that water precipitates scale where the two meet: in the rock around producers, in the tubing, in safety valves and chokes, and in separators. Barium sulphate is very hard to dissolve, so prevention is the practical route. Scale inhibitor squeezes can control it, but at high barium and high seawater fraction the inhibitor demand and the number of squeezes can become impractical.

Reservoir souring. Sulphate-reducing bacteria use sulphate as their electron acceptor and produce hydrogen sulphide. Injecting seawater supplies both the sulphate and, near the injector, a cooler zone where the bacteria thrive. The result can be rising H2S in produced gas and fluids, with consequences for materials, safety and gas processing. Reducing the sulphate in the injection water limits the substrate available to the bacteria. It is one of several controls, alongside biocide and nitrate treatment, and is usually considered together with them.

Why not RO? RO would also remove sulphate, but it removes the sodium chloride too. That costs far more pressure and energy, and a low-salinity injection water can make clays in some reservoirs swell or migrate. NF keeps most of the salinity, which suits many reservoirs, and rejects the divalent sulphate ion strongly because of its charge and size.

How a sulphate-removal unit is laid out

A typical offshore or coastal SRU runs in this order:

  1. Seawater intake and coarse screening, with continuous or shock chlorination against marine growth.

  2. Fine filtration. Hollow-fibre UF gives a steady, low-SDI feed and handles algal blooms better than media filters. See our ultrafiltration membranes. Media filtration with coagulation is the older alternative.

  3. Dechlorination with sodium metabisulphite and an ORP check, because polyamide NF membranes do not tolerate free chlorine.

  4. Antiscalant dosing and cartridge filters, typically 5 micron.

  5. NF in two stages, often in a 2:1 or similar array of 8040 elements in pressure vessels, with the first-stage concentrate feeding the second stage.

  6. Deaeration, often vacuum deaeration with an oxygen scavenger, then biocide, and the injection pumps.

The NF concentrate carries most of the sulphate and calcium at three to four times the feed concentration. Calcium sulphate and strontium sulphate saturation in the second-stage concentrate set the practical recovery limit, together with the antiscalant supplier's limits. Most SRUs stop at about 75 % recovery for that reason.

Arabian Gulf feed: what changes

Gulf seawater is harder on an SRU than open-ocean water:

  • Higher salinity. TDS of about 42,000 to 46,000 mg/L and sulphate of about 3,100 to 3,500 mg/L, against roughly 35,000 and 2,700 mg/L in the open ocean. More sulphate to remove, and a higher osmotic pressure difference across the membrane.

  • High and variable temperature. Typically 20 to 35 °C through the year. Warm water lowers the feed pressure, but sulphate passage rises with temperature, so check the permeate at the hot end of the range. Pumps must cover the cold end.

  • Biological and organic load. Algal blooms, high biological activity and shallow intakes raise biofouling risk. UF pretreatment and a sound biocide and cleaning plan matter more here.

  • Hydrocarbon traces. Near production facilities, oil traces can reach the intake. They foul both UF and NF and must be kept out of the feed.

Our post on Gulf seawater RO pressure, boron and recovery covers the same feed water from the RO side.

Worked example: a 30,000 m³/d SRU on Gulf seawater

Illustrative values only. Gulf seawater at 3,300 mg/L sulphate, 75 % NF recovery, two stages, target 40 mg/L sulphate in the injection water.

Item

Typical value

Injection water (NF permeate)

30,000 m³/d

NF feed

40,000 m³/d

NF concentrate

10,000 m³/d

UF feed, at about 93 % UF recovery

about 43,000 m³/d

Average feed-side concentration factor at 75 % recovery

about 1.85

Permeate sulphate at 99.5 % average rejection

about 30 mg/L (meets 40 mg/L)

Permeate sulphate at 99.0 % average rejection

about 60 mg/L (fails 40 mg/L)

Concentrate sulphate at 99.5 % rejection

about 13,100 mg/L

Feed pressure

typically 22 to 30 bar, depending on temperature and fouling

Two points stand out. First, half a percentage point of rejection doubles the permeate sulphate, so the target must be checked at the end-of-life condition and at the highest feed temperature, not on new elements at 25 °C. Second, the concentrate is four times the feed sulphate and carries the rejected calcium and strontium, so its scaling limits govern the recovery.

The permeate sulphate is estimated as feed sulphate × average concentration factor × (1 − rejection). The mass balance gives the concentrate: (40,000 × 3,300 − 30,000 × 30) ÷ 10,000.

What to do

  1. Start from the reservoir. Get the formation water analysis, especially barium, strontium and calcium, and the expected seawater fraction at the producers over field life.

  2. Agree the sulphate target with the reservoir and production chemistry team. Typical targets sit between about 20 and 50 mg/L for scale control; souring control alone may accept a higher figure. Include the scale inhibitor programme in the decision.

  3. Analyse the seawater through the year: temperature range, TDS, sulphate, calcium, strontium, SDI, algal seasons and any hydrocarbon risk at the intake.

  4. Design the pretreatment first. UF gives the most stable NF feed on difficult seawater; confirm dechlorination with ORP monitoring.

  5. Size the NF at the worst case: highest temperature and end-of-life rejection for permeate quality; lowest temperature and fouled elements for pump pressure.

  6. Set the recovery from the concentrate chemistry with the antiscalant supplier, not from the permeate target.

  7. Plan monitoring and cleaning. Normalise flow, pressure drop and sulphate passage (see RO and UF normalisation), and check the cleaning chemicals against the element limits (see membrane cleaning limits).

  8. Send us the analyses and the target through our enquiry form.

Questions engineers ask

What sulphate target should we set?

It depends on the barium and strontium in the formation water, the seawater fraction at the producers and the scale inhibitor strategy. Many projects set a figure between about 20 and 50 mg/L. Lower targets cost more membrane area or a lower recovery, so the figure should come from a scaling study rather than habit.

Does sulphate removal stop souring completely?

Not on its own. It removes most of the substrate, but bacteria can still use the remaining sulphate and the sulphate already in the formation water. It is usually combined with biocide treatment and sometimes nitrate dosing.

Can we inject the NF concentrate?

Not into the same reservoir, as it carries about four times the feed sulphate. It is usually returned to sea under the discharge permit.

Why not use RO for sulphate removal?

RO removes the sulphate, but also most of the sodium chloride, at much higher pressure and energy. The low-salinity water may also harm some clay-bearing reservoirs. NF does the specific job at lower cost.

How does produced water fit in?

Many fields reinject produced water as well as, or instead of, seawater. Produced water has its own treatment needs: oil, suspended solids and scaling ions. See our produced water membranes page.

Where do Theway products fit?

Theway's listed range does not include an NF element. Stream UF, our PVDF out-in hollow fibre UF, suits seawater pretreatment ahead of an SRU, and our produced water range covers the produced water side. For an SRU enquiry, send us the seawater and formation water analyses and the sulphate target through our enquiry form, and we will advise on the pretreatment and what we can supply.

Specification note: The sulphate levels, rejections, recoveries, pressures and flows above are typical, illustrative engineering values for the stated example, not results for any particular element or plant. They are for information only and are not a performance guarantee. Sulphate targets must be set from a reservoir scaling and souring study, and antiscalant limits must be confirmed with the antiscalant supplier. Actual performance depends on the feed water, pretreatment, temperature, operation and cleaning. See the product and datasheet disclaimer.

Comments