Boron in desalinated water: second pass, pH and limits

2 hours ago
6 min read

The short answer

Seawater carries about 4.5–6 mg/L of boron. At normal seawater pH most of it is uncharged boric acid, which polyamide membranes reject far less well than salt. A standard single pass on warm Gulf water typically leaves 1.5–2 mg/L in the permeate.

What to design for depends on the use of the water, not on the membrane:

Use of the water

Typical boron limit (mg/L)

Usual route on warm seawater

Drinking water, WHO guideline

2.4

Standard single pass

Drinking water, many project specifications

1.0

High-boron single pass

Irrigation of sensitive crops (citrus, avocado, berries)

0.3–0.5

Partial or full second pass at raised pH

Boiler feed, process water

Set by the process

Second pass, often with polishing

Three rules cover most designs:

  • Check boron at the hottest feed. Boron passage climbs steeply with temperature.

  • Try a high-boron element before adding a pass. On a 1 mg/L specification it is often enough on its own.

  • Use a partial second pass at raised pH when the limit is below about 0.7 mg/L, and treat only as much permeate as the limit needs.

Why boron gets through seawater RO

Boron is present as boric acid, B(OH)₃, and its ion, borate, B(OH)₄⁻. The balance between them is set by pH:

  • Below about pH 8.5, boric acid dominates. It is small and uncharged, so it passes through a polyamide membrane much as water does. In seawater at pH 8.1, only about a quarter of the boron is borate.

  • Above about pH 10, borate dominates. The charged ion is rejected well, like other salts. In low-salinity RO permeate, about 85 % of the boron is borate at pH 10 and about 95 % at pH 10.5.

  • Salinity shifts the balance. The dissociation constant (pKa) of boric acid is about 9.2 in fresh water but about 8.6–8.7 in seawater at 25 °C. The figures above are typical; the exact split depends on salinity and temperature.

Temperature works against the designer. Warm water makes the membrane more permeable to boric acid, and the effect is much stronger than for salt. In the Theway Compass example in Gulf seawater RO: pressure, boron and recovery, the same train rejects 79 % of the boron at 22 °C but only 64 % at 35 °C. Permeate boron rises from 1.16 to 1.99 mg/L across that range.

Membrane ageing also matters. Boron passage creeps up as elements age and after harsh cleaning, so design with an allowance for membrane age, not for new elements.

Which limit to design for

WHO guideline: 2.4 mg/L. The World Health Organization raised its guideline to 2.4 mg/L in 2011. On drinking water alone, a standard single pass usually complies, even in summer.

Project specifications: often 1.0 mg/L. Many utilities and contracts still specify 1.0 mg/L, sometimes as a maximum and sometimes as an average. Read the clause carefully: a 1.0 mg/L maximum at 35 °C is a much harder design than a 1.0 mg/L annual average. European drinking water rules set 1.5 mg/L, with 2.4 mg/L allowed where desalinated water is the main source.

Irrigation: 0.3–0.75 mg/L. Boron is a plant micronutrient, but the gap between enough and too much is narrow. Sensitive crops such as citrus, avocado, stone fruit and berries show leaf damage when irrigation water carries more than about 0.5–0.75 mg/L. Where desalinated water reaches agriculture, directly or through treated wastewater reuse, specifications of 0.3–0.5 mg/L are common.

Industrial water. Boiler feed and some process waters set their own limits, often well below drinking water values. A second pass is usually needed anyway, for silica and total dissolved solids, and boron comes with it.

The options, from lightest to heaviest

1. High-boron first-pass elements. A tighter polyamide layer rejects more boric acid at the cost of more feed pressure. In the Gulf example at 35 °C and 40 % recovery, seven Osmoflux MR TW 400 HB high-boron elements in each vessel give 0.96 mg/L, against 1.99 mg/L with the standard element. Feed pressure rises from 64.9 to 74.8 bar, and specific energy from 2.80 to 3.19 kWh/m³.

2. Raised first-pass pH. Lifting the seawater feed to about pH 8.8–9 helps boron a little, but calcium carbonate and magnesium scale limit how far you can go at seawater concentration. It is a small trim, not a solution.

3. Partial second pass at raised pH. In a split-partial design, the permeate from the front of each vessel, which is lowest in boron, goes straight to product. The permeate from the rear elements, which carries most of the boron, is dosed with caustic soda to about pH 10–10.5 and treated in a brackish RO pass. Its concentrate, still cleaner than seawater, goes back to the first-pass feed.

4. Full second pass. All first-pass permeate is treated. This gives the lowest boron but the largest second-pass train and caustic dose.

5. Boron-selective ion exchange. A polishing step for very low limits or for a small side stream. It needs acid and caustic regeneration and is outside the scope of this post.

Worked example: how much permeate to treat

Basis (illustrative): the Gulf train from the linked post, 200 m³/h of product at 35 °C, with standard Osmoflux MR TW 400 elements in the first pass giving 1.99 mg/L of boron. Typical front-to-rear split of first-pass permeate boron: the front 40 % of permeate at about 1.25 mg/L, the rear 40 % at about 2.9 mg/L. Second pass on Osmoflux brackish elements at pH 10, 90 % recovery, with an assumed 90 % boron rejection.

Design

Share of first-pass permeate treated

Product boron (mg/L)

Notes

Standard single pass

0 %

1.99

Meets WHO 2.4 only

High-boron single pass (MR TW 400 HB)

0 %

0.96

Compass result from the linked post

Partial second pass

40 % (rear)

about 1.0

Meets 1.0 with standard elements

Partial second pass

60 % (rear)

about 0.7

Meets most irrigation limits

Full second pass

100 %

about 0.2

For the tightest limits

These are illustrative mass balances, not Compass results. They show the pattern: treating the rear 40 % halves the boron, and each further step costs more second-pass capacity and caustic for a smaller gain.

Combining the routes also works. High-boron elements in the first pass and a smaller partial second pass can reach 0.5 mg/L with less treated flow than either route alone. Run each combination in Theway Compass at your hottest and coldest feed.

What to do

  1. Pin down the limit. Is it a maximum or an average? At which temperature? For drinking water, irrigation or both?

  2. Measure feed boron. Use a laboratory result for your intake, not a textbook value. Gulf and Red Sea water typically carries 5–6 mg/L.

  3. Model the hottest month. Check boron at the highest feed temperature and with an allowance for membrane age.

  4. Try a high-boron first pass first. If it meets the limit within the elements' pressure rating, it is usually the simplest plant.

  5. Size a partial second pass for the remainder. Treat the rear permeate, start at about 40 % and increase until the limit is met at the hottest feed.

  6. Design the second pass for high pH. Dose antiscalant, keep recovery at about 85–90 %, check magnesium hydroxide and calcium carbonate scaling in the concentrate, and allow for re-adjusting product pH during remineralisation.

  7. Check element limits. Keep each element within its pH, pressure and temperature ratings. See membrane cleaning limits and the RO membranes range.

Questions engineers ask

Why not just run the whole first pass at pH 10?

At seawater concentration, calcium carbonate and magnesium hydroxide would scale the membranes within hours. First-pass permeate has little hardness left, so raising its pH in a second pass is practical.

Does boron rejection improve in winter?

Yes, markedly. In the Gulf example, boron falls from 1.99 mg/L at 35 °C to 1.16 mg/L at 22 °C. Some plants run a second pass only in the warm months and bypass it in winter.

How much caustic soda does the second pass need?

It depends on the alkalinity and carbon dioxide in the first-pass permeate. Model it for your water; the dose rises sharply above pH 10.5, so do not raise the pH further than the limit needs.

Can the second-pass concentrate be recycled?

Yes. It is much cleaner than seawater, so it usually goes back to the first-pass feed. This recovers water and reduces the intake flow slightly.

Does a high-boron element affect anything else?

It needs more feed pressure, so check the high-pressure pump and the elements' pressure rating at the coldest feed. Permeate TDS is usually lower too.

Can Theway supply both first-pass and second-pass elements?

Yes. Osmoflux seawater elements, including the high-boron MR TW 400 HB, and Osmoflux brackish elements for the second pass are made in the standard 8-inch format. Send an enquiry with your feed analysis and boron limit.

Specification note: The figures above are typical values, Theway Compass estimates and illustrative mass balances for the stated design basis. They are for information only and are not a performance guarantee. Actual boron removal depends on the feed water, temperature, pH, membrane age, pre-treatment and operation. See the product and datasheet disclaimer.