top of page

Disc tube RO for leachate: open channels and high pressure

2 hours ago
6 min read

The short answer

Landfill leachate carries organic matter, colloids, high ammonia and a lot of salt, all at once. Two things follow:

  1. It fouls quickly. A spiral-wound element, with its narrow spacer-filled channel, traps the solids and the biofilm. Open-channel disc tube modules have no feed spacer and a short, turbulent flow path, so they can be cleaned back and keep running.

  2. The concentrate gets salty very fast. As recovery rises, the osmotic pressure of the concentrate can pass 60 to 90 bar. Standard spiral RO is rated to about 41 to 83 bar. Disc tube modules in 75, 90, 120 and 160 bar classes, as in Theway's Discflux DT 75/90/120/160 range, let you choose the pressure that matches the recovery you need.

In short: the open channel deals with fouling, and the pressure class sets the recovery.

What is in leachate, and why it matters to RO

Leachate changes with the age of the landfill. The figures below are typical ranges from the literature, not limits for any one site.

Parameter (typical)

Young leachate (under about 5 years)

Old, stabilised leachate (over about 10 years)

COD

5,000 to 40,000 mg/L

500 to 4,000 mg/L

BOD/COD

above 0.4

below 0.1

Ammonium (NH4-N)

500 to 2,000 mg/L

500 to 3,000 mg/L

Conductivity

10 to 30 mS/cm

8 to 25 mS/cm

Chloride

1,000 to 4,000 mg/L

1,000 to 3,000 mg/L

pH

5.5 to 7.0

7.5 to 8.5

What each of these does to the membrane:

  • Humic and fulvic substances dominate old leachate and lay down a sticky organic layer on the membrane.

  • Ammonium is the parameter most discharge limits care about. RO rejects the ammonium ion well, but free ammonia (NH3) passes through. Above pH 8, more of it is in the free form, so leachate RO is usually acidified to about pH 6 to 6.5 before the membranes.

  • Calcium, carbonate, sulphate, iron and silica give scaling risk once they are concentrated four to ten times.

  • Suspended solids, colloids and bacteria give particle fouling and biofouling.

So leachate fouls in every way at once, and the module has to be easy to clean.

Why open channels help

In a spiral-wound element, the feed flows through a mesh spacer about 0.7 to 0.9 mm thick. Solids and biofilm catch on that spacer. Once it blocks, pressure drop rises and cleaning reaches the blocked areas poorly.

A disc tube module is built differently. Flat membrane cushions are stacked between hydraulic discs on a central tie rod. The feed runs across each cushion in an open channel without a spacer, turns at the edge of the disc, and runs back across the next one. In practice this gives:

  • A short flow path on each disc, with frequent changes of direction. These keep the flow turbulent and limit the build-up of a fouling layer.

  • Nothing in the channel for solids to catch on. Fouling stays on the membrane surface, where a clean can reach it.

  • High crossflow velocity along the whole stack, from a recirculation loop around the modules.

  • Easy service. A module can be opened and individual cushions replaced.

The trade-off is less membrane area per module than an 8040 spiral. On a clean feed, that is a poor trade. On leachate, it is usually why the plant keeps running. For a less difficult feed, see the Osmoflux RO range.

Why high pressure matters: recovery against osmotic pressure

As a rule of thumb, osmotic pressure rises by about 0.75 bar for every 1,000 mg/L of dissolved salts (sodium-chloride basis). With about 98 % rejection, the concentrate is roughly the feed concentration divided by (1 − recovery). Leachate already starts at 8,000 to 20,000 mg/L of TDS, so the pressure climbs steeply with recovery.

The feed pressure has to cover:

  • the osmotic pressure of the concentrate, plus

  • a net driving pressure for useful flux, plus

  • an allowance for fouling and for the pressure drop through the stack.

Here we take that margin as about 20 to 30 bar.

Worked example (illustrative)

The feed is 100 m³/d of leachate at 12,000 mg/L TDS, acidified and filtered. The figures below are rounded and illustrative, not a design.

Recovery

Concentrate TDS (approx.)

Concentrate osmotic pressure (approx.)

Feed pressure needed (typical)

Suitable class

Concentrate volume

60 %

30,000 mg/L

23 bar

45 to 55 bar

DT 75

40 m³/d

75 %

48,000 mg/L

36 bar

55 to 65 bar

DT 75

25 m³/d

80 %

60,000 mg/L

45 bar

65 to 75 bar

DT 90

20 m³/d

85 %

80,000 mg/L

60 bar

80 to 90 bar

DT 120

15 m³/d

90 %

120,000 mg/L

90 bar

110 to 120 bar

DT 160

10 m³/d

Two points stand out:

  • Going from 80 to 90 % recovery halves the concentrate volume, but it needs about 45 bar more feed pressure. Whether that pays off depends on what the concentrate costs to dispose of.

  • Leave headroom. In the 80 % row, for example, DT 90 is chosen over DT 75 because 75 bar leaves no margin for fouling or for a salty season. As the landfill ages and conductivity drifts upwards, a class with margin keeps the plant at its design recovery.

At high recovery, scaling often becomes the limit before pressure does. Calcium sulphate, barium sulphate and silica in the concentrate must be checked against their solubility. Run the feed analysis through Theway Compass to see the scaling picture at each recovery. Then pick the antiscalant dose and acid set-point before you fix the pressure class.

Recovery and concentrate handling

Plants often use stages:

  • A first disc tube stage at 75 or 90 bar works on the raw or pretreated leachate.

  • A high-pressure concentrate stage at 120 or 160 bar takes the first-stage concentrate and reduces its volume further.

  • A permeate stage, as a second pass on the first-stage permeate, is often added to meet tight limits for ammonium, COD or conductivity.

The concentrate still has to go somewhere. Common routes, subject to local permits:

  • Return to the landfill body, where the permit allows. Over time this raises the salt load in the leachate.

  • Evaporation or drying, often fed by the high-pressure stage to cut the volume that must be evaporated.

  • Solidification with binders before disposal.

  • Off-site treatment by tanker, where each cubic metre saved counts most.

What to do

  1. Characterise the leachate over a full year. Measure COD, BOD, NH4-N, conductivity, chloride, sulphate, calcium, barium, silica, iron, pH and TSS, in both wet and dry seasons.

  2. Set the recovery from the concentrate route. Work out what one cubic metre of concentrate costs to handle, and what volume the site can accept.

  3. Check scaling and osmotic pressure at that recovery in Theway Compass. Then set the acid dose (to about pH 6 to 6.5) and the antiscalant dose.

  4. Choose the Discflux pressure class with headroom: DT 75 or 90 for first stages, and DT 120 or 160 for concentrate stages.

  5. Plan pretreatment. Use a sand filter and a cartridge filter at a minimum, and remove iron where needed. If biological pretreatment is used, see MBR.

  6. Plan cleaning from day one. Use alternate alkaline and acid cleans, and follow normalised flux and pressure so that you clean before you lose recovery. See also membrane cleaning limits.

  7. Send the analysis through Send enquiry for a Discflux configuration review.

Questions engineers ask

Can I use spiral-wound RO on leachate instead?

Sometimes, on well-pretreated leachate (after an MBR and UF, for example) at moderate recovery. On raw or partly treated leachate, the spacer channel usually fouls too fast.

Why acidify the feed?

Acid keeps ammonium in its ionised form, which RO rejects well, and it controls calcium carbonate scaling. A pH of about 6 to 6.5 is typical. Acid choice matters: sulphuric acid adds sulphate, which raises the risk of calcium sulphate scale at high recovery.

Which pressure class do I need?

Take the osmotic pressure of the concentrate at your target recovery and add about 20 to 30 bar. Then pick the next class up from DT 75, 90, 120 and 160, with margin for the salt load to rise over time.

How often does a leachate disc tube plant need cleaning?

Weekly to monthly is typical, depending on the leachate and pretreatment. Base the timing on normalised data, not the calendar.

Does a permeate stage always need to be added?

No. It depends on the discharge limits, especially for ammonium. Where limits are tight or feed ammonium is high, a second pass is common.

Can higher recovery replace evaporation?

It reduces the evaporation load but rarely removes it; some concentrate always remains.

Specification note: the leachate ranges, osmotic pressures, feed pressures and recoveries in this post are typical or illustrative engineering values for discussion, not a performance guarantee. Actual design depends on site analysis, pretreatment and operating conditions. See the product and datasheet disclaimer.