top of page

Disc tube RO for landfill leachate: sizing Discflux modules from 90 to 160 bar

3 days ago
2 min read

Updated: 11 hours ago

At a glance: landfill leachate carries ammonium, organics, bicarbonate and salt at levels that foul and scale ordinary spiral elements. Disc tube RO stacks membrane cushions around open, short flow paths and runs a recirculation loop at high velocity, so it tolerates this water and can be cleaned back. Discflux modules come in 75, 90, 120 and 160 bar classes.

Why disc tube for leachate

  • Open channels with no feed spacer to trap solids and biofilm.

  • A loop pump keeps the velocity high across every module, whatever the recovery.

  • Modules open for inspection and individual cushions can be replaced.

  • Pressure classes up to 160 bar take the concentrate further than spiral elements.

Worked example

Leachate at about 15,500 mg/L TDS with 1,500 mg/L ammonium and 7,500 mg/L bicarbonate. Sulfuric acid takes the feed to pH 6.5 first, which keeps ammonia as ammonium (which the membrane rejects) and limits carbonate scale; at this alkalinity the dose is about 2,000 mg/L. Projected with Theway Compass:


First stage

Brine concentrator

Modules

10 × 3 Discflux DT 90

30 × 3 Discflux DT 160

Permeate

4 m³/h at 75 % recovery

10 m³/h at 85 % recovery

Feed pressure

About 44 bar

About 78 bar

Permeate TDS

About 670 mg/L

About 380 mg/L

Ammonium in permeate

About 73 mg/L (95 % removed)

About 41 mg/L

Concentrate

About 60 g/L

About 98 g/L

Specific energy

About 2.6 kWh/m³

About 3.8 kWh/m³

Most leachate plants pass the first-stage permeate through a second RO stage to meet discharge limits for ammonium and COD. At high recovery the design check also watches silica: in the brine concentrator above, silica reaches about 156 % of saturation and Compass suggests lowering the recovery or confirming the antiscalant.

Choosing the pressure class

Discflux model

Use

Lower-salinity effluent and polishing stages

Typical leachate first stage

Higher recovery or saltier leachate

RO brine concentration ahead of evaporation

Compass picks the lowest class that carries the feed pressure with margin and warns when a cheaper class would do.

Questions

Why not spiral elements? They can work after thorough pretreatment, but they foul quickly on raw leachate. Compass flags spiral designs on leachate and suggests disc tube.

How often are modules cleaned? Leachate plants clean far more often than water plants, typically weekly to monthly with alkaline and acid solutions. Compass includes cleaning chemicals in the running cost.

Figures are Theway Compass projections for the water and design shown, for information only. Leachate varies with the age of the landfill; pilot testing is advised.

Related: see the Osmoflux RO range and size your plant in Theway Compass.

Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.

Comments


bottom of page