How to read an RO membrane datasheet: tests and limits
The short answer
An RO membrane datasheet tells you how one new element performs under one standard test: a set feed salinity, pressure, recovery and temperature. It is a quality-control and comparison tool, not a forecast of what your plant will produce.
Read it in three parts:
The test conditions box defines the numbers. Permeate flow and rejection mean nothing without the NaCl concentration, pressure, recovery, temperature and pH they were measured at.
The tolerances tell you the spread between elements. Permeate flow is typically quoted at ±15 % of nominal, and rejection as a stabilised value with a lower minimum.
The operating limits are hard boundaries: maximum pressure, temperature, pressure drop, feed flow, pH and chlorine. Exceed them and the warranty and the element are both at risk.
A typical brackish 8040 element rated at about 40 m³/d on test will usually produce only 18 to 25 m³/d in a real plant, and that is the design working as intended.
The test conditions box
Every element is tested on a clean sodium chloride (NaCl) solution, not on real water. Typical standard conditions for 8-inch elements are:
Element type | Test NaCl (mg/L) | Pressure | Recovery (single element) | Temperature | pH |
|---|---|---|---|---|---|
Brackish water, standard | 2,000 | 15.5 bar (225 psi) | 15 % | 25 °C | 7–8 |
Brackish water, low energy | 500–2,000 | 6.9–10.3 bar (100–150 psi) | 15 % | 25 °C | 7–8 |
Seawater | 32,000 | 55 bar (800 psi) | 8 % | 25 °C | 7–8 |
Typical industry values. Always read the conditions printed on the specific datasheet.
Three things to check:
Pressure and NaCl together. A low-energy element tested at 10.3 bar and a standard element tested at 15.5 bar cannot be compared on permeate flow without correcting for net driving pressure.
Recovery is per element, not per plant. 15 % recovery on one element means very little concentration build-up. A plant at 75 % recovery concentrates the feed four times, so the last elements see much higher osmotic pressure.
Temperature. 25 °C is the reference. Permeate flow typically falls by about 2.5 to 3 % for each degree below 25 °C at the same pressure, so at 15 °C you would need noticeably more pressure for the same flow.
The test salt matters too: real water contains silica, boron, bicarbonate and nitrate, each rejected less well than NaCl.
Flow tolerance and stabilised rejection
Flow tolerance. If a datasheet says 40 m³/d ±15 %, any element between 34 and 46 m³/d on the factory test is in specification. Across a full vessel the elements average out, so do not judge one element against the nominal figure.
Stabilised rejection. Rejection is usually given as two figures: a stabilised (nominal) value, such as 99.5 %, and a minimum, such as 99.3 %. The factory reading is typically taken after about 30 minutes of operation. In service, rejection usually improves and settles over the first 24 to 48 hours of continuous running as the membrane compacts and wets fully. A new element that reads slightly low on its first hour is not necessarily faulty.
Rejection depends on flux. Salt passes through the membrane at a rate that hardly depends on pressure, while water flow rises with pressure. Run an element at a lower flux than its test and its percentage rejection falls, even though nothing is wrong with it. This is one reason plant permeate TDS is higher than the datasheet suggests.
Operating limits
The limits table is the part of the datasheet to treat as non-negotiable. Typical values for 8040 elements:
Limit | Brackish water (typical) | Seawater (typical) |
|---|---|---|
Maximum operating pressure | 41 bar (600 psi) | 69–83 bar (1,000–1,200 psi) |
Maximum feed temperature | 45 °C | 45 °C |
Maximum pressure drop per element | 1.0 bar (15 psi) | 1.0 bar (15 psi) |
Maximum pressure drop per vessel | 3.4 bar (50 psi) | 3.4 bar (50 psi) |
Maximum feed flow per element | 16–17 m³/h | 16–17 m³/h |
Minimum concentrate flow per element | 3–4 m³/h | 3–4 m³/h |
pH, continuous operation | 2–11 | 2–11 |
pH, short-term cleaning | 1–13 | 1–13 |
Free chlorine | below 0.1 mg/L, ideally not detectable | below 0.1 mg/L |
Feed SDI15 | below 5 | below 5 |
Feed turbidity | below 1 NTU | below 1 NTU |
Pressure-drop limits protect against telescoping. The minimum concentrate flow limits concentration polarisation at the membrane surface. Chlorine damage to polyamide is cumulative: low but continuous exposure slowly destroys rejection. For safe cleaning ranges, see membrane cleaning limits.
Why datasheet flow is not plant flow
The datasheet flow is a test result. Plant flow is set by the design flux you choose for your feed water, typically in litres per square metre per hour (LMH).
Typical design flux ranges:
RO permeate or very clean feed: 30–40 LMH
Well water, SDI below 3: 20–28 LMH
Surface water after UF: 18–25 LMH
Surface water after media filtration: 14–20 LMH
Tertiary wastewater after UF: 14–18 LMH
Seawater open intake: 11–17 LMH
A standard 8040 brackish element with 37 m² of area rated at 40 m³/d is running at about 45 LMH on test. A plant on surface water treated by UF would typically average about 20 LMH, under half the test flux. Lower flux slows fouling, keeps cleaning intervals long and protects the lead elements, which always run harder than the average.
Higher salinity and recovery, colder water, fouling and ageing all reduce output further, and tail elements produce much less than lead elements.
Worked example: comparing two datasheets fairly
Two illustrative 8040 brackish elements, both 37 m² and tested at 25 °C and 15 % recovery:
Element A (standard) | Element B (low energy) | |
Test NaCl | 2,000 mg/L | 1,500 mg/L |
Test pressure | 15.5 bar | 10.3 bar |
Rated permeate flow | 39.7 m³/d | 36.3 m³/d |
Stabilised rejection | 99.5 % | 99.3 % |
Approximate net driving pressure on test | 13.5 bar | 8.7 bar |
Flow per bar of net driving pressure | 2.9 m³/d/bar | 4.2 m³/d/bar |
Approximate rejection if run at the same flux as A | 99.5 % | about 99.5 % |
Illustrative values. Net driving pressure here is feed pressure less average osmotic pressure and half the element pressure drop, simplified.
At first sight A gives more water. Corrected for driving pressure, B is about 40 % more permeable: it would make the same flow at a much lower pressure, which saves energy on low-salinity feeds. Its lower test rejection is largely a flux effect; at the same flux the two are close. The right choice depends on your feed salinity, temperature and the permeate quality you need, so compare them in a projection, not on the headline numbers.
What to do
Read the test box first. Write down NaCl, pressure, recovery, temperature and pH before looking at flow or rejection.
Compare on permeability, not headline flow. Correct for net driving pressure, or better, run both elements through the same projection.
Use stabilised rejection with flux in mind. Expect lower rejection at low flux and in the tail of a high-recovery system.
Design on flux for your feed water, not on datasheet flow. Run the design in Theway Compass and choose Osmoflux elements from the RO membranes range.
Check every limit against your worst case: coldest water for pressure, hottest for temperature, end-of-run fouling for pressure drop.
Track normalised data from start-up so you can tell real decline from changes in temperature and feed. See RO and UF normalisation.
Questions engineers ask
My new elements give 10 % less flow than the datasheet. Are they faulty?
Probably not. Check that you are comparing at the same pressure, temperature, salinity and recovery. A single element within ±15 % of nominal is in specification, and plant conditions almost never match the test.
Why is my plant permeate TDS higher than the datasheet rejection suggests?
Because the plant runs at lower flux, higher average salinity and higher recovery than the test, and real ions such as bicarbonate, nitrate and silica are rejected less well than NaCl.
Can I run an element at its test pressure all the time?
The test pressure is not a limit; the maximum operating pressure is. What matters is the flux and the lead-element flux that result, which should stay within the design range for your feed water.
Is seawater rejection comparable to brackish rejection?
Not directly. Seawater elements are tested at 32,000 mg/L and 55 bar, and their quoted rejection, typically 99.7 % or more, reflects that test. Compare seawater elements only with other seawater elements on the same test basis. Send us an enquiry if you would like help reading a datasheet.
Specification note: The figures above are typical or illustrative engineering values for information only and are not a performance guarantee. Datasheet values apply only under the stated test conditions. Actual RO performance depends on the feed water, pre-treatment, system design, operation and cleaning. See the product and datasheet disclaimer.