MBR chemical cleaning: maintenance and recovery cleans

2 hours ago
6 min read

The short answer

  • Two kinds of clean. A maintenance clean is short, mild and frequent: typically 100 to 500 mg/L sodium hypochlorite for 30 to 60 minutes, one to three times a week. A recovery clean is long and strong: typically 1,000 to 2,000 mg/L hypochlorite, then an acid, soaking for 4 to 12 hours, every 3 to 12 months.

  • Hypochlorite for organics, acid for inorganics. Hypochlorite removes biofilm and organic fouling. Citric acid (typically 2,000 to 5,000 mg/L, pH 2 to 3) removes scale and most metals. Oxalic acid (typically 0.5 to 1 %) is better where iron is the main problem.

  • Clean on permeability, not on the calendar alone. Correct permeability to 20 °C and trend it. A recovery clean is typically due when it falls to about 50 % of the clean value, or when transmembrane pressure (TMP) reaches the supplier's limit.

  • Count the chlorine. Every clean adds to the membrane's lifetime chlorine exposure. Keep a log in mg·h/L and compare it with the datasheet limit.

Maintenance cleans and recovery cleans

Maintenance cleans stop fouling from building up between recovery cleans. On a hollow-fibre MBR, the plant usually runs them automatically. The permeate pump stops, and a chemical solution is backpulsed from the permeate side into the fibres in short pulses, with soaks in between. The mixed liquor stays in the tank and the scour air keeps running. The whole sequence takes typically 30 to 75 minutes per train.

Typical settings:

  • Hypochlorite maintenance clean: 100 to 500 mg/L free chlorine (200 mg/L is a common starting point), one to three times a week.

  • Acid maintenance clean: citric acid at 1,000 to 2,000 mg/L, typically weekly to monthly, more often where the feed or coagulant brings iron, aluminium or calcium.

Recovery cleans restore permeability that maintenance cleans no longer reach. They use higher strengths and longer soaks:

  • Hypochlorite recovery clean: 1,000 to 2,000 mg/L free chlorine, soaked for typically 4 to 12 hours. Some flat-sheet suppliers allow stronger solutions; follow their datasheet.

  • Acid recovery clean: citric acid at 2,000 to 5,000 mg/L, pH 2 to 3, or oxalic acid at 0.5 to 1 % for iron. Soak for typically 4 to 8 hours.

Do the hypochlorite stage first in most municipal plants, because organic fouling usually dominates. Where scale or iron is the main foulant, do the acid first. Rinse between the two stages, and never let hypochlorite and acid meet: together they release chlorine gas.

In-situ and ex-situ cleaning

In-situ, mixed liquor in the tank. This is how maintenance cleans run. Only the chemical inside the fibres and on their surface reaches a high strength. The small volume that passes into the tank is diluted in the mixed liquor and has little effect on the biology at typical doses.

In-situ, tank drained. This is the usual recovery clean. The train is isolated and the membrane tank drained of mixed liquor, then either filled with cleaning solution or the solution is backpulsed in from the permeate side and left to soak. Draining keeps strong chemicals away from the biomass and lets you inspect the cassettes for sludging and hair.

Ex-situ (tank-out soak). The cassette is lifted out and soaked in a separate cleaning tank. Use this when fibres are badly sludged, packed with hair or rag, or when a single cassette needs work while the others keep running. Hose off sludge before the soak, so the chemical reaches the membrane and is not spent on sludge.

Hollow fibre and flat sheet. Hollow-fibre modules, including reinforced PVDF types such as Surge MBR, are cleaned by backpulsing chemical from the inside of the fibre outwards. Flat-sheet modules usually cannot be backpulsed hard, so the chemical is fed into the permeate side by gravity at low pressure and left to soak. In both cases the chemical reaches the fouling from behind, which is why it works.

Checking the result from permeability

TMP alone can mislead, because it changes with flux and temperature. Use permeability:

  • Permeability (L/m²·h·bar) = flux (L/m²·h) ÷ TMP (bar).

  • To correct to 20 °C, multiply by the ratio of water viscosity at the operating temperature to viscosity at 20 °C. At 15 °C that ratio is about 1.14; at 12 °C, about 1.23.

Trend permeability daily. Typical triggers:

  • Maintenance clean frequency: if permeability falls faster than the planned interval allows, clean more often or switch chemical.

  • Recovery clean: permeability at 20 °C at about 50 % of the clean value, or TMP at the supplier's limit (often around 50 to 60 kPa for hollow fibre in suction), whichever comes first.

  • After a recovery clean: expect typically 85 to 100 % of the clean value. If recovery is poor and drops further after each clean, look at the biology (filterability, foaming, MLSS) and the screens before you blame the membrane.

Worked example (illustrative)

One train, gross flux 18 L/m²·h, clean permeability 225 L/m²·h·bar at 20 °C. The recovery clean runs at 15 °C (viscosity ratio 1.14).

Stage

Temperature

TMP (bar)

Permeability at T (L/m²·h·bar)

Permeability at 20 °C

% of clean value

Clean, at start-up

20 °C

0.080

225

225

100 %

Before recovery clean

15 °C

0.180

100

114

51 %

After hypochlorite stage (1,000 mg/L, 6 h)

15 °C

0.110

164

186

83 %

After citric stage (2,000 mg/L, 6 h)

15 °C

0.095

189

215

96 %

What it shows:

  • At 15 °C the TMP before the clean (18 kPa) looked moderate, but permeability at 20 °C had halved. The trigger was correct.

  • The acid stage recovered a further 13 points. Inorganic fouling was a real part of the problem, so the acid maintenance clean should run more often.

Chlorine exposure for the same train (illustrative):

  • Maintenance cleans: 200 mg/L × 1 h contact × 2 a week × 52 weeks = 20,800 mg·h/L a year.

  • Recovery cleans: 1,000 mg/L × 6 h × 3 a year = 18,000 mg·h/L a year.

  • Total: about 38,800 mg·h/L a year, or about 390,000 mg·h/L over ten years.

Compare that with the lifetime limit on the module datasheet and in our membrane cleaning limits. If the log is heading past it, cut the frequency or strength of the cleans, or fix the cause of the fouling.

What to do

  1. Record the clean permeability at 20 °C in the first weeks after start-up. Every trigger depends on it.

  2. Trend permeability daily, corrected to 20 °C, for each train.

  3. Set maintenance cleans: hypochlorite at typically 200 mg/L, one to three times a week; citric acid weekly to monthly. Adjust the frequency from the trend.

  4. Set the recovery clean trigger: about 50 % of clean permeability or the supplier's TMP limit.

  5. For a recovery clean, isolate and drain the tank, hose off any sludging, run hypochlorite then acid (or acid first for scale and iron), and rinse between stages.

  6. Neutralise spent solutions before return or discharge: sodium bisulphite for chlorine, caustic for acid.

  7. Measure permeability after each stage, and keep a chlorine exposure log per train.

  8. If recovery is falling clean after clean, check screening, aeration and sludge filterability before changing the chemicals.

For replacement or new modules, see Surge MBR: reinforced PVDF hollow fibre made in Chennai, India, as equivalents for ZeeWeed 500-format cassettes. For chemical strengths, pH and temperature limits by membrane type, see membrane cleaning limits.

Questions engineers ask

Can I use a stronger hypochlorite clean less often?

Within the datasheet limits, yes, but total exposure is what ages the membrane. Many plants find that frequent mild cleans hold permeability better than rare strong ones, because fouling is easier to remove before it consolidates.

Does a maintenance clean harm the biology?

At typical doses, little. The chlorine is concentrated in the fibres and diluted in the tank. Watch nitrification on small plants with many trains cleaned at once, and stagger the cleans.

Why use oxalic acid instead of citric?

Oxalic acid forms stronger complexes with iron, so it often works better where iron from the feed or from ferric dosing is the main foulant. It is more hazardous to handle, so check your site procedures.

Can I add caustic to the hypochlorite?

Some suppliers allow it, typically to pH 10 to 11, to help remove organics. Check the membrane's pH limits first, and do not exceed them during the soak.

Why does recovery get worse after each clean?

Usually because some fouling is not removed by either chemical, or because the cause is still there: poor screening, low aeration, hair, or poor sludge filterability. Fix the cause before increasing chemical strength.

Can Surge MBR modules use our existing cleaning system?

Often, where the existing cassettes are the ZeeWeed 500 format and the cleaning system backpulses from the permeate side. Send your cleaning procedure and tank layout through our enquiry form and we will check it.

Specification note: The chemical strengths, contact times, frequencies, triggers and worked example in this article are typical or illustrative engineering values to show the method. They are not measurements from any plant and not a performance guarantee. Clean to the supplier's datasheet and cleaning limits for the specific modules. See the product and datasheet disclaimer.