MBR design flux and aeration: getting both numbers right
The short answer
Say which flux you mean. Gross flux is the rate while the membrane is filtering. Net flux is what you get over a whole cycle, after relaxation, backpulse and cleaning time. Size the membrane area on net flux; check fouling against gross flux.
Size for the hardest case, not the average. Check three cases: average flow, peak flow, and average flow with one train out for a clean. The largest area wins. That is often the case with a train out, not the peak.
Correct for cold water. Water at 12 °C is about 23 % more viscous than at 20 °C. At the same transmembrane pressure (TMP), flux falls to about 0.81 of the 20 °C value. Set design fluxes at the coldest monthly sewage temperature.
Set aeration per square metre, then check it per cubic metre. Typical specific aeration demand for reinforced hollow fibre is 0.2 to 0.4 Nm³ of air per m² of membrane per hour (SADm). Divided by net flux, that gives SADp, typically 10 to 25 Nm³ of air per m³ of permeate.
Budget the downtime. Relaxation, backpulse and maintenance cleans all take time away from filtration.
Gross flux, net flux and the filtration cycle
Submerged MBR membranes do not filter continuously. A typical cycle is 8 to 12 minutes of filtration followed by 30 to 90 seconds of relaxation (the permeate pump stops while the scour air keeps running) or a short backpulse with permeate.
With relaxation only, net flux is gross flux multiplied by the share of time spent filtering:
10 minutes filtering and 1 minute relaxing gives 10/11 = 0.91, so a gross flux of 20 L/m²·h gives a net flux of 18.2 L/m²·h.
A backpulse costs twice: the time it takes, and the permeate pushed back through the membrane. Net flux is then (gross flux × filtration time − backpulse flux × backpulse time) ÷ total cycle time.
Two 45-minute maintenance cleans a week take a further 1 % or so of filtering time.
A "25 L/m²·h" design can mean gross or net, and the difference is close to 10 % of the membrane area. Always ask.
Peak flows and trains out of service
Municipal MBRs usually see peak flows of 1.5 to 3 times the average daily flow, and the membranes cannot be bypassed. A submerged membrane can usually run at a higher flux for a limited time, typically hours to a day or two. The fouling must then be recovered at lower flows.
Three checks set the membrane area:
Average flow, all trains in service, at the sustainable gross flux for the design temperature.
Peak flow, all trains in service, at the short-term peak gross flux for the design temperature.
Average flow with one train out for a recovery clean or repair, at the sustainable flux.
If peaks last longer than the membranes tolerate, an equalisation tank is often cheaper than more area. Do not schedule recovery cleans in wet weather or at the daily peak.
Temperature correction
Permeate flux at a given TMP is inversely proportional to the viscosity of the permeate. Pure water viscosity is about 1.00 mPa·s at 20 °C and 1.24 mPa·s at 12 °C, so the correction factor is about 0.81.
Cold mixed liquor also tends to foul more, as biological activity slows. The viscosity correction is the minimum allowance, not a safety margin. Use the coldest monthly sewage temperature.
Membrane aeration: SADm and SADp
Coarse-bubble air rising through the fibres scours the membrane and controls the cake layer. It is typically a third to a half of an MBR's energy use.
SADm (Nm³/m²·h) is air per square metre of membrane per hour. It is what the cassette needs to stay clean. Typical values are 0.2 to 0.4 for reinforced hollow fibre with cyclic aeration. Flat-sheet designs are often higher.
SADp (Nm³/m³) is air per cubic metre of permeate. It measures efficiency. SADp = SADm ÷ net flux in m/h.
The two pull against each other. Extra membrane area lowers the flux, but it needs scour air too, so SADp rises unless spare trains go on standby at low flows. Cyclic aeration and idling trains at night keep SADp down. Never go below the supplier's minimum air per cassette: under-aerated fibres sludge up quickly.
Worked example
Basis (illustrative): a municipal MBR with an average daily flow of 4,000 m³/d (166.7 m³/h) and a peak of 2.0 times average (333.3 m³/h). There are four membrane trains. The coldest monthly sewage temperature is 12 °C. The cycle is 10 minutes filtering and 1 minute relaxing (net/gross = 0.909). Typical gross flux limits at 20 °C are 25 L/m²·h sustained and 40 L/m²·h at peak. At 12 °C (× 0.81) these become 20 and 32 L/m²·h.
Check | Flow | Gross flux limit at 12 °C | Net flux | Area needed in service | Installed area needed |
|---|---|---|---|---|---|
Average, 4 trains | 166.7 m³/h | 20 L/m²·h | 18.2 L/m²·h | 9,167 m² | 9,167 m² |
Peak, 4 trains | 333.3 m³/h | 32 L/m²·h | 29.1 L/m²·h | 11,458 m² | 11,458 m² |
Average, 3 of 4 trains | 166.7 m³/h | 20 L/m²·h | 18.2 L/m²·h | 9,167 m² | 12,222 m² |
The train-out case governs. Round up to 12,400 m², or four trains of 3,100 m². The resulting operating points are:
Case | Area in service | Gross flux | Membrane air at SADm 0.30 | SADp |
|---|---|---|---|---|
Average, 4 trains | 12,400 m² | 14.8 L/m²·h | 3,720 Nm³/h | 22.3 Nm³/m³ |
Average, 3 trains (one on standby) | 9,300 m² | 19.7 L/m²·h | 2,790 Nm³/h | 16.7 Nm³/m³ |
Peak, 4 trains | 12,400 m² | 29.6 L/m²·h | 3,720 Nm³/h | 11.2 Nm³/m³ |
Peak, 3 trains | 9,300 m² | 39.4 L/m²·h | 2,790 Nm³/h | 8.4 Nm³/m³ |
What it shows:
At average flow, run three trains. With all four aerated, SADp is 22.3 Nm³/m³. With one train rotated onto standby, it falls to 16.7 Nm³/m³, and the gross flux of 19.7 L/m²·h is still inside the 20 L/m²·h limit.
Do not clean a train during a peak. With three trains, peak flow needs 39.4 L/m²·h gross, well above the 32 L/m²·h limit.
Low SADp at peak is not a target. It reflects a few hours of high flux.
What to do
Fix the flow profile: average, maximum month, peak hour and how long peaks last. Also fix the coldest monthly sewage temperature.
Get the supplier's sustainable and peak gross flux at 20 °C, and say whether each figure is gross or net. Correct them to the design temperature.
Set the filtration cycle (relaxation or backpulse) and the maintenance clean frequency. Work out the net-to-gross ratio.
Run the three area checks and take the largest. Add an equalisation tank if peaks are long.
Set membrane aeration from the supplier's SADm and minimum air per cassette. Check SADp at average flow, and plan standby trains and cyclic aeration for low flows.
Plan the cleans. Typical maintenance cleans use 100 to 500 mg/L sodium hypochlorite, one to three times a week, with a citric acid clean when scale or metals build up. Recovery cleans at higher strength are typically every 3 to 12 months, or when permeability at 20 °C has fallen by an agreed amount. Keep within the limits in membrane cleaning limits and the module datasheet.
For new plants and replacements, see Surge MBR: reinforced PVDF hollow-fibre modules made in Chennai, India, as equivalents for ZeeWeed 500-format cassettes. For existing tanks, see direct retrofit. If the MBR permeate feeds an RO stage for reuse, project that stage in Theway Compass.
Questions engineers ask
Should a design flux be quoted gross or net?
Quote both. Net flux sizes the membrane area. Gross flux is what the membrane sees while filtering, so fouling limits apply to it.
Can I raise the flux to save membrane area?
Only within the supplier's sustainable flux for your temperature. Above it, fouling builds faster than relaxation and maintenance cleans remove it, and you pay in chemicals, downtime and module life.
How long can an MBR run at peak flux?
Typically hours to a day or two, depending on the supplier and conditions. Permeability should recover at lower flows afterwards. If it does not, the peak is too high or too long.
Can membrane aeration be reduced at night?
Yes, by taking trains offline or using the supplier's low-flow aeration mode. Do not cut air below the minimum per cassette on trains that are filtering.
Does the 0.81 temperature factor cover everything?
No. It covers permeate viscosity only. Cold mixed liquor usually fouls faster too, so some designers derate the cold-weather flux further or add an equalisation tank.
Can Surge MBR modules go into an existing plant?
Often, where the existing cassettes are the ZeeWeed 500 format. Send the tank drawings, cassette layout and flow data through our enquiry form and we will check the fit.
Specification note: The fluxes, aeration rates, cleaning concentrations and worked example in this article are typical or illustrative engineering values to show the method. They are not measurements from any plant and not a performance guarantee. Design to the supplier's datasheet and cleaning limits for the specific modules. See the product and datasheet disclaimer.