Troubleshooting an MBR: rising TMP, foam and poor sludge

1 hour ago
6 min read

The short answer

  • Normalise first. Convert flux and TMP into permeability at 20 °C. A slow fall that tracks sewage temperature is normal; a sharp fall over days is a fouling event.

  • Most TMP problems start upstream of the membrane: hair passing a damaged screen, sludge that filters badly, or scour air that misses some fibres. A clean will not fix these for long.

  • Check in order: fine screen, then the biology (MLSS, SRT, F/M, filterability), then recirculation and tank levels, then aeration, then the modules themselves.

  • Foam is usually biological or surfactant. Brown, stable foam points to filamentous bacteria; white, billowing foam points to surfactants or young sludge. Only use antifoam that the membrane supplier approves: some silicone antifoams foul membranes.

  • Clean when permeability falls; replace when cleans stop restoring it or the interval between them keeps shrinking.

Symptoms and where to look first

Symptom

Likely causes

First check

TMP rising steadily over weeks

Temperature fall; gradual organic fouling; maintenance cleans too weak or too rare

Permeability at 20 °C; maintenance clean log and hypochlorite strength

TMP jump over hours or days

Sludging between fibres; aeration failure; MLSS spike; flux above the sustainable limit

Blower and air header pressure; membrane tank MLSS; flow records

Permeability not recovering after a clean

Sludged or braided bundles; scale or metals needing an acid clean; irreversible fouling

Pull and inspect one cassette; check the acid clean history

Foaming

Filamentous bacteria; surfactants; high F/M at start-up; low SRT

Foam colour and stability; microscope check; SRT and loading

Poor permeate (turbidity, solids)

Broken fibres; leaking seals or O-rings; damaged permeate pipework

Turbidity by train; isolate cassettes one at a time

Sludge packed between fibres, hair wrapped on fibres

Screen bypass or damage; low or uneven scour air; MLSS too high

Screen condition; air distribution pattern; MLSS

Biological causes: MLSS, SRT and filterability

MLSS. Submerged hollow-fibre MBRs typically run at 8 to 12 g/L in the membrane tank. Above roughly 12 to 15 g/L, sludge viscosity rises steeply, scour air works less well and sludge starts to pack between the fibres. The recirculation flow back to the biology, typically 4 to 5 times the forward flow, limits how far the membrane tank concentrates. If a recirculation pump trips or its flow falls, membrane tank MLSS climbs within hours.

SRT and F/M. Municipal MBRs typically run at a sludge age (SRT) of 15 to 30 days. A short SRT or a high food-to-microorganism ratio (F/M) leaves more soluble microbial products and extracellular polymeric substances (EPS) in the liquor. These are the main MBR foulants. Longer SRT lowers them, but too long favours foaming organisms.

Filterability. Low dissolved oxygen, a toxic or saline discharge or a sudden temperature drop changes the sludge before the MLSS figure. A time-to-filter or capillary suction time test, weekly and after any upset, shows it. A worse result with an unchanged MLSS is a biological problem, not a membrane problem.

Mechanical causes: screens, hair and aeration

Fine screening. Hollow fibres need fine screening ahead of the biology, typically 1 to 3 mm, often after a coarser bar screen. Hair and fibres that pass the screen wrap round the fibres and the cassette frame ("braiding" or "ragging"), trap sludge and create dead zones that no clean reaches. Look for torn mesh, worn seals, gaps at the frame, storm overflows, and unscreened streams such as tanker discharges or return liquors joining after the screen.

Aeration distribution. Scour air only controls the cake layer where it rises through the fibres. Common faults:

  • Aerators blocked with sludge, often after the air stops and mixed liquor flows back. Use the flushing routine if there is one.

  • A cassette that is not level, so air escapes up one side.

  • One header or valve partly closed, or a damaged pipe venting air.

  • A blower below rated output, or cyclic aeration valves stuck.

With the tank at operating level, the surface "boil" should be even over every cassette. A flat patch over part of a cassette means that part is not being scoured.

Flux. Running above the sustainable flux for the water temperature, during long peaks or with a train out, raises TMP however good the sludge and air are.

Foam: causes and control

MBRs foam readily: sludge ages are long, aeration is intense, and there is no clarifier to skim foam away.

  • White, crisp, billowing foam: surfactants, or young sludge at start-up or after a loss of biomass. It usually clears as the SRT rises.

  • Brown, thick, stable foam: filamentous organisms, typically Microthrix parvicella (favoured by cold water, fats and low dissolved oxygen) or nocardioforms such as Gordonia (favoured by fats, oils and grease and long sludge ages). A microscope check confirms which.

  • Dark, grey or black foam: septic conditions or an anoxic zone running anaerobic.

Control the cause: waste sludge from the surface so foam is not recycled, cut fats at source, keep dissolved oxygen up and review SRT. Sprays help short term. Antifoam is a last resort, and only a product the membrane supplier has approved in writing.

Worked example: is the TMP rise real?

Basis (illustrative): a submerged MBR at a constant gross flux of 20 L/m²·h. Permeability = flux ÷ TMP, corrected to 20 °C by the ratio of water viscosities (1.138 mPa·s at 15 °C, 1.002 mPa·s at 20 °C, a factor of 1.136).

Day

Temperature

TMP

Permeability as measured

Permeability at 20 °C

Reading

0

20 °C

0.12 bar

167 L/m²·h·bar

167 L/m²·h·bar

Baseline after a recovery clean

30

15 °C

0.16 bar

125 L/m²·h·bar

142 L/m²·h·bar

Mostly temperature; normal drift

37

15 °C

0.24 bar

83 L/m²·h·bar

95 L/m²·h·bar

Fouling event: 33 % lost in a week

40

15 °C

0.32 bar

63 L/m²·h·bar

71 L/m²·h·bar

Still falling: find the cause now

What it shows:

  • Over the first 30 days the measured permeability fell by 25 %, but only 15 % of that was fouling. The rest was colder water.

  • The fall from day 30 to day 37 is not temperature. It calls for the checks in the next section before any clean. A clean on day 40 without a cause will just buy a few days.

What to do

  1. Trend permeability at 20 °C per train, daily, with the date of each clean.

  2. Check the fine screen and every stream that joins after it. Repair gaps and bypasses first.

  3. Check the biology: MLSS in the biological and membrane tanks, recirculation flow, SRT, dissolved oxygen, and a filterability test.

  4. Check the air: blower output, header pressure, valve positions and the surface boil over each cassette. Flush the aerators.

  5. Check the flux: flows, trains in service and any extended peaks.

  6. Inspect a cassette. Lift the worst one. Packed sludge or hair confirms a screen, air or MLSS fault; hose out sludge gently before any chemical clean.

  7. Clean to the limits. Use hypochlorite for organics and citric or another acid for scale and metals, within the concentrations, pH and temperatures in membrane cleaning limits and the module datasheet.

  8. Decide on replacement when recovery cleans no longer restore an agreed share of the original permeability, cleans are needed more and more often, or broken fibres keep spoiling the permeate. Reinforced PVDF modules typically last 7 to 10 years in municipal service, but condition decides, not age.

For replacement modules, see Surge MBR: reinforced PVDF hollow fibre made in Chennai, India, as equivalents for ZeeWeed 500-format cassettes. For existing tanks and frames, see direct retrofit.

Questions engineers ask

How fast is too fast for a TMP rise?

Compare with your own trend at 20 °C. A creep that maintenance cleans hold is normal. Losing tens of percent of permeability in a week at steady flux and temperature is a fouling event.

Should I clean straight away when TMP jumps?

Not before checking air, MLSS and the screen. If fibres are sludged, a chemical clean cannot reach the packed sludge, and if the cause is still there, TMP climbs again within days.

Does more scour air always help?

Up to a point. Even distribution matters more than total air. Raising blower output does not help a cassette whose aerators are blocked.

Does a broken fibre mean replacing the module?

Not usually. Isolate it and plug the fibres if the design allows. Replace when breaks keep recurring.

Can you help diagnose a plant?

Send your permeability trend, MLSS, SRT, cleaning log and photographs of a lifted cassette through our enquiry form and we will review them.

Specification note: The TMP, permeability, MLSS, SRT, screening and module life figures in this article are typical or illustrative engineering values to show the method. They are not measurements from any plant and not a performance guarantee. Operate to the supplier's datasheet, operating manual and cleaning limits for the specific modules. See the product and datasheet disclaimer.