top of page

Pentair UF modules replaced at a seawater desalination plant in South India

Nov 16
2 min read

Updated: 11 hours ago

At a glance: The ultrafiltration pretreatment of an existing seawater reverse osmosis desalination plant in South India was retrofitted with Theway UF modules in place of its Pentair modules. The contract covered design, manufacture, supply, installation and commissioning. In the seven-day performance guarantee run in September 2014 the 220 m³/h system delivered filtrate turbidity of 0.05 NTU and SDI of 0.5.

Theway UF modules in a seawater RO pretreatment retrofit
Theway UF modules in the retrofitted pretreatment skid

The installation

Item

Detail

Plant

Seawater reverse osmosis desalination plant

Region

South India

Application

UF pretreatment ahead of seawater RO, 220 m³/h

Modules replaced

Pentair UF modules

Contract scope

Design, manufacture, supply, installation and commissioning

Guarantee run

Seven working days, September 2014

Certified result

Parameter

Required

Achieved

Turbidity

Below 0.5 NTU

0.05 NTU

SDI (15 minutes)

Below 3.0

0.5

Low and steady SDI is what protects seawater RO membranes from fouling. Why UF does this better than media filters is covered in UF as RO pretreatment, and rack sizing in UF for seawater RO pretreatment.

How a direct replacement fits

A Theway direct replacement module is made to the dimensions and connections of the module it replaces, so it goes into the existing rack, couplings and pipework. The plant keeps its frames, valves and controls; only the modules change.

Replacements for each Pentair model are listed in Replacing Pentair X-Flow UF modules.

Send the make and model of your modules, how many there are and your feed water analysis to mail@thewaymembranes.com, or find your module in the retrofit finder to see the Theway equivalent and its datasheet.

Customer names are not published. Other plants running Theway membranes are listed on our Milestones page.

Related: see the direct-retrofit UF range and size your plant in Theway Compass.

Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.

Comments