top of page

Replacing Pentair X-Flow UF modules: Theway retrofits by model

Nov 12
3 min read

Updated: 3 hours ago

At a glance: Theway makes direct retrofits for the Norit, later Pentair X-Flow, UF range. Agua modules replace Aquaflex, Twiga replaces Xiga, Trident replaces Seaflex and Poseidon replaces Seaguard, each in 40, 55 and 64 sizes, plus Agua 20. All are rated at equivalence level 7: the same form, ports, dimensions, membrane material, MWCO, fibre dimensions and performance, so they fit the existing racks and pipework.

Replacing Pentair X-Flow UF modules: Theway retrofits by model

Pentair replacements in service

Theway UF modules replacing Pentair modules at a steel plant
Theway modules in a former Pentair skid, steel plant, Central India

Model cross-reference

Existing module

Theway retrofit

Equivalence level

Aquaflex 20

Agua 20 (20 m²)

7

Aquaflex 40

Agua 40 (40 m²)

7

Aquaflex 55

Agua 55 (55 m²)

7

Aquaflex 64

Agua 64 (64 m²)

7

Xiga 40

7

Xiga 55

7

Xiga 64

7

Seaflex 40

7

Seaflex 55

7

Seaflex 64

7

Seaguard 40

7

Seaguard 55

7

Seaguard 64

7

Brand and model names belong to their owners and are used here only to identify the modules each Theway retrofit replaces.

What level 7 means

Theway rates every retrofit on an eight-level scale. Level 7 matches form and shape, module port size, module dimensions, membrane material, MWCO, fibre dimensions and performance. Level 8 adds operating philosophy. At level 7 the module drops into your existing housings and racks, and we review your cycle settings (filtration time, backwash and flush) against the Theway datasheet before start-up. The full scale is on the direct retrofit page.

Planning the changeover

  1. Record what you have. Model on the nameplate, number of modules and trains, photos of the module ends, couplings and rack.

  2. Send operating data. Flow, feed and filtrate pressures, cycle settings and cleaning history. This shows whether the old modules failed from age, fouling or operation.

  3. Confirm the match. We confirm the retrofit model and the cycle settings to use.

  4. Replace a whole train. New modules have higher permeability than fouled ones. In a mixed train the new modules take more of the flow and foul faster.

  5. Install and flush. Inspect couplings and O-rings, replace any that are worn, install, then flush out the preservative to drain. See commissioning new UF modules.

  6. Log a baseline. Record flow, TMP and temperature on the first day. Every later reading is compared with it.

Checklist

  • Nameplate model and quantity

  • Photos of module ends, ports and rack

  • Current cycle settings and cleaning chemicals

  • Spare O-rings and couplings on site

  • Drain route for preservative flush water

  • Baseline readings planned for day one

Questions buyers ask

Do I need to change pipework or racks?

No. Level 7 retrofits match port sizes and module dimensions.

Can I mix Theway and original modules in one train?

It works hydraulically, but we advise replacing a full train so all modules share the same permeability and age.

Do I keep the same cleaning chemicals?

Usually yes. Check them against the Theway datasheet limits: cleaning pH 1 to 13 at up to 40 °C, operating pH 2 to 11 and 20 to 45 °C, as on the Agua, Twiga, Trident and Poseidon datasheets.

Which retrofit for seawater?

Trident and Poseidon replace the Seaflex and Seaguard modules used on seawater duties. Tell us the feed and we will confirm.

Retrofit guides by maker

Get a retrofit quotation

Send the model, quantity and photos through Send Enquiry or to mail@thewaymembranes.com. For other brands, see Hydranautics HYDRAcap, DuPont SFP and Koch, Suez and Hyflux.

Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.

Comments


bottom of page