Replacing Pentair X-Flow UF modules: Theway retrofits by model
Updated: 3 hours ago
At a glance: Theway makes direct retrofits for the Norit, later Pentair X-Flow, UF range. Agua modules replace Aquaflex, Twiga replaces Xiga, Trident replaces Seaflex and Poseidon replaces Seaguard, each in 40, 55 and 64 sizes, plus Agua 20. All are rated at equivalence level 7: the same form, ports, dimensions, membrane material, MWCO, fibre dimensions and performance, so they fit the existing racks and pipework.

Pentair replacements in service

Integrated steel plant, Central India: Pentair UF modules replaced with Theway modules, 2026
Steel plant, South India: Aquaflex 64 replaced with Agua 64, in service since May 2023, at least 90% recovery
Seawater desalination plant, South India: Pentair UF pretreatment retrofitted, 220 m³/h, 0.05 NTU and SDI 0.5 in the guarantee run
Model cross-reference
Brand and model names belong to their owners and are used here only to identify the modules each Theway retrofit replaces.
What level 7 means
Theway rates every retrofit on an eight-level scale. Level 7 matches form and shape, module port size, module dimensions, membrane material, MWCO, fibre dimensions and performance. Level 8 adds operating philosophy. At level 7 the module drops into your existing housings and racks, and we review your cycle settings (filtration time, backwash and flush) against the Theway datasheet before start-up. The full scale is on the direct retrofit page.
Planning the changeover
Record what you have. Model on the nameplate, number of modules and trains, photos of the module ends, couplings and rack.
Send operating data. Flow, feed and filtrate pressures, cycle settings and cleaning history. This shows whether the old modules failed from age, fouling or operation.
Confirm the match. We confirm the retrofit model and the cycle settings to use.
Replace a whole train. New modules have higher permeability than fouled ones. In a mixed train the new modules take more of the flow and foul faster.
Install and flush. Inspect couplings and O-rings, replace any that are worn, install, then flush out the preservative to drain. See commissioning new UF modules.
Log a baseline. Record flow, TMP and temperature on the first day. Every later reading is compared with it.
Checklist
Nameplate model and quantity
Photos of module ends, ports and rack
Current cycle settings and cleaning chemicals
Spare O-rings and couplings on site
Drain route for preservative flush water
Baseline readings planned for day one
Questions buyers ask
Do I need to change pipework or racks?
No. Level 7 retrofits match port sizes and module dimensions.
Can I mix Theway and original modules in one train?
It works hydraulically, but we advise replacing a full train so all modules share the same permeability and age.
Do I keep the same cleaning chemicals?
Usually yes. Check them against the Theway datasheet limits: cleaning pH 1 to 13 at up to 40 °C, operating pH 2 to 11 and 20 to 45 °C, as on the Agua, Twiga, Trident and Poseidon datasheets.
Which retrofit for seawater?
Trident and Poseidon replace the Seaflex and Seaguard modules used on seawater duties. Tell us the feed and we will confirm.
Retrofit guides by maker
Get a retrofit quotation
Send the model, quantity and photos through Send Enquiry or to mail@thewaymembranes.com. For other brands, see Hydranautics HYDRAcap, DuPont SFP and Koch, Suez and Hyflux.
Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.





Comments