top of page

RO pressure vessels: rating, ports and how to choose

2 hours ago
6 min read

The short answer

  • Rate the vessel for the highest pressure the system can reach, not the normal operating pressure. That includes cold feed, fouled elements at end of life and the pump's maximum (shut-off) pressure unless a relief valve protects the vessels.

  • Typical classes: 300 psi (20.7 bar) for low-salinity brackish and second-pass duties, 450 psi (31.0 bar) for most brackish and industrial reuse duties, 1,000 psi (69.0 bar) for seawater. Theway's Armaflux 80-300-EP, 80-450-SP and 80-1000-SP cover these three classes.

  • Choose the port style for the pipework. End ports suit small systems with few vessels. Side ports make the manifold shorter, allow multi-port headers and let you open a head without removing the feed or concentrate pipe.

  • Elements per vessel set the array. Six 8040 elements per vessel is the usual brackish choice. Six or seven is usual in seawater. Fewer elements per vessel means more vessels, more pipework and more footprint for the same membrane area.

  • Maintenance matters as much as specification. Thrust ring position, head seals, strap tension and safe depressurisation decide vessel life.

Matching the pressure rating to the duty

The design pressure on a vessel datasheet is the maximum operating pressure at the maximum operating temperature. On all three Armaflux models it applies up to 65 °C. The design basis is the ASME Boiler and Pressure Vessel Code, Section X, which covers fibre-reinforced plastic vessels.

The feed pressure you see on a new plant is not the number to design to. Work up from it:

  1. Start with the projected feed pressure at the design temperature, from a projection such as Theway Compass.

  2. Add the cold-water case. Water permeability falls by roughly 3 % per °C. A plant designed at 25 °C can need 25 to 35 % more pressure at 15 °C.

  3. Add a fouling and ageing allowance. Typical design practice allows 10 to 20 % more pressure by end of element life.

  4. Check the pump. If the high-pressure pump can reach a higher pressure than the vessel rating (for example against a closed concentrate valve), fit a relief valve or high-pressure trip set below the vessel rating.

Typical classes by duty:

Duty (typical)

Typical feed pressure

Vessel class

Low-salinity brackish, municipal, second pass

7 to 15 bar (100 to 220 psi)

300 psi (20.7 bar), e.g. Armaflux 80-300-EP

Brackish 2,000 to 10,000 mg/L, industrial reuse, NF

12 to 28 bar (175 to 400 psi)

450 psi (31.0 bar), e.g. Armaflux 80-450-SP

Seawater 35,000 to 45,000 mg/L, high-TDS brines

50 to 69 bar (725 to 1,000 psi)

1,000 psi (69.0 bar), e.g. Armaflux 80-1000-SP

Use 300 psi only if the cold, end-of-life pressure sits well inside 20.7 bar. If it is close, move up to 450 psi. For seawater, the 1,000 psi class covers normal single-pass duties, including warm, high-salinity Gulf feed. Brines that need more than 69 bar are a duty for disc tube modules, not spiral-wound vessels.

Check the permeate side too. On Armaflux heads the permeate port is rated for 125 psi (8.6 bar). Permeate pressure must also never exceed feed pressure by more than about 0.3 bar (5 psi), or the membrane can delaminate. Fit a check valve or vent so a closed permeate valve or a second-pass pump cannot reverse the pressure.

End port or side port

End-port vessels take feed and concentrate through the centre of the heads. The Armaflux 80-300-EP has 1.5-inch grooved ports through each head. They suit small skids with few vessels, but you must disconnect the feed or concentrate pipe to open a head.

Side-port vessels take feed and concentrate through ports in the shell near each end. This brings three benefits:

  • Shorter manifolds. Vessels sit in a compact rack fed from a common header.

  • Multi-port headers. With multi-port heads, flow passes from one vessel's port straight into the next, so the vessels form part of the header. The Armaflux 80-1000-SP offers 1.5, 2 and 2.5-inch multi-port side ports for this.

  • Easier access. The head can be removed without touching the feed or concentrate pipe. Only the permeate connection is undone.

When vessels form part of a header, the ports carry the flow of several vessels. Check the port velocity. As an illustration, 8 m³/h through a 1.5-inch port is about 2 m/s, while 24 m³/h for three vessels would be about 5.5 m/s through the same port. A 2.5-inch port brings that back to about 2 m/s. Follow the port flow limits on the vessel datasheet.

Elements per vessel

All three Armaflux models take one to seven 8-inch × 40-inch elements. The element count changes the array, not the membrane chemistry:

  • Brackish: six elements per vessel is usual. A two-stage 2:1 array with six-element vessels typically reaches 70 to 80 % recovery.

  • Seawater: six or seven elements per vessel in a single stage, typically 40 to 50 % recovery.

  • Small or pilot plants: one to four elements per vessel.

Longer vessels mean fewer heads and shorter manifolds. Keep the pressure drop per vessel within the element supplier's limit (typically about 3.5 bar or 50 psi for a six-element vessel), and keep per-vessel flows inside the element limits.

A seven-element vessel is about 7.7 m long; leave a similar clear length at one end for loading.

Why FRP

Armaflux shells are filament-wound epoxy and glass, with the head-locking grooves wound into the shell rather than machined. FRP does not corrode in seawater or cleaning chemicals and is much lighter than stainless steel. The stated limits are −7 to 65 °C, pH 3 to 11 in service and pH 2 to 12 for cleaning of under 30 minutes.

FRP shells stretch slightly in length and diameter under pressure. Straps must let the shell move, and grooved flexible couplings keep pipe loads off the ports.

For small skids, see Theway's 8040 and 4040 FRP housings.

Worked example (illustrative)

A brackish train treats 6,000 mg/L feed at 75 % recovery to give 36 m³/h of permeate. It uses 400 ft² brackish elements from the Osmoflux range.

Item

Illustrative value

Array

6:3 vessels, 6 elements each (54 elements)

Feed per stage-1 vessel

8 m³/h

Concentrate per stage-2 vessel

4 m³/h

Projected feed pressure, new, 25 °C

16 bar

Same at 15 °C

20 bar

With 15 % fouling and ageing allowance

23 bar

Relief valve set point

28 bar

300 psi vessel (20.7 bar)

Not suitable: exceeded in the cold, fouled case

450 psi vessel (31.0 bar)

Suitable, with margin above the relief set point

Choice

Armaflux 80-450-SP-6, side port, nine vessels

The 300 psi class covers the new, warm case but not winter or end of life. The 450 psi class covers every case.

What to do

  1. Run a projection at the coldest feed temperature and with a fouling allowance. Take the highest feed pressure.

  2. Choose the lowest vessel class whose design pressure sits clearly above that figure and above the relief or trip setting.

  3. Pick end port for small, simple skids and side port for racks, multi-port headers and easy head removal.

  4. Set the elements per vessel from the array, then check the pressure drop and flows per vessel.

  5. On installation, put the thrust ring at the concentrate end, shim the element stack to remove end play and leave loading space at the feed end.

  6. Before opening any head, stop the pumps, isolate, drain and confirm zero pressure on the feed, concentrate and permeate sides.

  7. At each element change, inspect head seals, locking rings and adapters, replace damaged O-rings and use the lubricant the element supplier allows.

Questions engineers ask

Can I use a 1,000 psi vessel on a brackish plant?

Yes, but it adds weight and usually cost with no gain in membrane performance. It makes sense if the feed may later become more saline.

What does the factory hydrostatic test pressure mean?

It is a factory proof test above design pressure, not an operating limit. Never run above the design pressure.

Can I run cleaning through the same vessels?

Yes. Cleaning runs at typically 2 to 4 bar. Keep pH and temperature within the vessel and element limits; see membrane cleaning limits.

Why does one vessel show high permeate conductivity?

Usually a leaking O-ring, interconnector or adapter, not a failed element. Probe the permeate tube to find it.

Will my existing 8040 elements fit?

Armaflux vessels have an inside diameter of 202.2 mm for standard 8-inch × 40-inch elements. Check the interconnector and adapter type against your elements before ordering.

Can I re-rate a vessel to a higher pressure?

No. The rating comes from the shell design and the test. If the duty changes, change the vessel class. Send an enquiry with the new feed pressure and array.

Specification note: The pressures, flows and recoveries in this article are typical values and an illustrative example, built to show the method. They are not measurements from any plant. Vessel ratings are as stated on the Armaflux datasheets; always follow the datasheet, the general arrangement drawing and the element supplier's instructions. This article is not a performance guarantee. See the product and datasheet disclaimer.