Sanitary tubular UF for dairy, juice and food plants
The short answer
Food duty needs a hygienic module. Stainless steel wetted parts, sanitary clamp connections, drainable surfaces and no dead legs let the plant clean in place every day.
Tubular UF suits the difficult food streams. Pulpy juice, viscous retentates and feeds with fibres or fat run through an open tube without fine prefiltration.
The concentration factor sets yield, flux and area. At a volume concentration factor (VCF) of 20, 95 % of the feed leaves as permeate.
Typical flux is 40 to 100 L/m²h for juice at about 50 °C and lower for dairy retentates.
CIP after every run is normal. A typical sequence is rinse, alkaline, rinse, acid, rinse, sanitise, all within the pH, temperature and oxidant limits on the datasheet.
Why stainless housings and sanitary fittings matter
In a food plant a module is judged not only on flux and rejection but on whether it can be cleaned to a verifiable standard every day. That changes the hardware.
Stainless steel shells and end fittings. 316L is the usual choice for wetted steel. It takes hot caustic and acid CIP without corroding.
Sanitary connections. Clamp-type ferrule joints with gaskets seat flush with the bore and come apart for inspection.
Smooth, drainable surfaces. Hygienic equipment is typically specified with a surface roughness of Ra 0.8 µm or better on product-contact steel, and pipework sloped so it drains fully.
No dead legs. A branch that the cleaning flow does not sweep will hold product and grow bacteria. A common rule is to keep branches shorter than about 1.5 to 2 pipe diameters.
Seal materials matched to the duty. EPDM is common for hot caustic and water but swells in fats and oils. FKM is often chosen for fatty streams. Check every gasket against the CIP chemicals and the product.
A stainless shell alone does not make a module food-grade. The membrane, potting and seals also touch the product, so ask for food-contact documentation for each wetted material.
Theway's Tubeflux T12-3030 SS and Tubeflux T12-4336 SS are sanitary tubular UF modules with stainless steel shells, in 3-inch and 4.3-inch sizes. Check the datasheet for tube bore, membrane area, materials, connection sizes and the operating limits of the model you select.
Typical duties in food and beverage plants
Juice clarification. After depectinising, fruit juice is ultrafiltered to remove haze, pulp, pectin fragments, yeasts and moulds. Sugars, acids and flavour pass into the permeate, which leaves clear. Tubular modules suit it because pulp and thick retentate would block a spiral spacer. Juice is often processed warm, around 45 to 55 °C, to lower viscosity and raise flux.
Whey and protein streams. UF retains whey protein while lactose, minerals and water pass. The degree of concentration, often helped by diafiltration (adding water to wash out more lactose), sets the protein content of the final concentrate. Dairy UF is usually run either cold, about 10 to 15 °C, to hold back microbial growth, or warm, about 50 °C, for higher flux. Tubular modules suit high-solids and fat-bearing dairy streams.
Process water and CIP recovery. Evaporator condensate, wash water and spent CIP rinses can be ultrafiltered to remove fat, protein and solids. The permeate is reused for non-product duties or polished by RO.
The concentration factor, explained
The volume concentration factor is:
VCF = feed volume ÷ retentate volume
At VCF 10, 100 m³ of feed gives 10 m³ of retentate and 90 m³ of permeate. Fully retained components, such as protein, are concentrated about tenfold. Freely passing components, such as sugar in juice, leave at feed concentration, so their yield in the permeate equals the permeate fraction. A higher VCF raises that yield but also raises retentate viscosity, which lowers flux and increases the area needed. Diafiltration recovers more of the passing component without pushing the VCF to its limit.
Worked example: clarifying 5 m³/h of apple juice
Basis (illustrative): 5 m³/h of depectinised apple juice at 50 °C, tubular UF in feed-and-bleed. Sugars are assumed to pass freely. The average flux at each VCF is an assumed typical value, not a test result. No diafiltration.
Target VCF | 10 | 20 | 30 |
|---|---|---|---|
Permeate (clear juice) | 4.50 m³/h | 4.75 m³/h | 4.83 m³/h |
Retentate | 0.50 m³/h | 0.25 m³/h | 0.17 m³/h |
Juice yield in permeate | 90 % | 95 % | 96.7 % |
Average flux (typical, assumed) | 70 L/m²h | 60 L/m²h | 50 L/m²h |
Membrane area needed | 64 m² | 79 m² | 97 m² |
Going from VCF 10 to VCF 30 lifts juice yield by under seven points but needs about half as much membrane again. Many plants stop near VCF 20 and recover more juice from the retentate by diafiltration.
Check the area with the UF sizing calculator, and see the membrane pore size guide for what UF does and does not retain.
A CIP sequence for food duty
Food UF is usually cleaned after every production run, often once a day. The sequence below is typical. The exact chemicals, concentrations, temperatures and times must stay within the Tubeflux datasheet and the membrane cleaning limits.
Step | Typical chemical | Typical pH | Typical temperature | Typical time |
|---|---|---|---|---|
1. Product displacement | Water | Neutral | Process temperature | Until the retentate runs clear |
2. Alkaline clean | Sodium hydroxide with a detergent or chelant | 10.5 to 11.5 | 45 to 50 °C | 30 to 45 min |
3. Rinse | Water | To neutral | Ambient to 45 °C | Until pH is neutral |
4. Enzyme clean (optional, for protein) | Protease formulation | 9 to 10 | 40 to 50 °C | 30 to 60 min |
5. Acid clean | Nitric, phosphoric or citric acid | About 2 | 45 to 50 °C | 20 to 30 min |
6. Rinse | Water | To neutral | Ambient | Until pH is neutral |
7. Sanitise | Oxidant or peracetic acid, only as the datasheet allows | As allowed | Ambient | 15 to 30 min |
Notes on the sequence:
Alkaline first for protein, fat and pectin. Acid first can set protein onto the membrane. In dairy, the acid step removes calcium phosphate.
Do not chase speed with heat. A membrane rated for pH 11.5 at 50 °C may not be rated for it at 60 °C.
Keep the cross-flow up during CIP, at or near production velocity.
Use clean water. Hard or iron-bearing rinse water redeposits scale.
Measure the result. Record clean water flux at a reference temperature after every CIP. A steady downward trend shows that the clean is not complete. See RO and UF normalisation.
What to do
Define the product and the target. State what must be retained, what must pass, the VCF or concentration you need, and the processing temperature.
Choose the module format. Use tubular modules where pulp, fibres, fat or high retentate viscosity would block a spiral. Use the Tubeflux T12 SS range where sanitary construction is required.
Check every wetted material. Get food-contact documentation for the membrane, potting, seals and steel. Match gasket elastomers to both product and CIP.
Design the skid hygienically, with drainable pipework, no dead legs and a heated CIP tank.
Size from conservative flux. Use the lower half of the typical range, or pilot data, at the VCF you actually plan to reach.
Put the datasheet pH, temperature and oxidant limits on the CIP operator sheet.
Pilot new products. A short trial on your own juice or whey settles flux, VCF and cleaning better than any table. Send us an enquiry.
Questions engineers ask
Why tubular instead of spiral UF for dairy?
For clean, low-viscosity whey, spiral elements are usually cheaper per square metre and widely used. Tubular modules earn their place when the stream carries pulp, fat or fibres, when the retentate becomes very viscous at high VCF, or when the plant wants to avoid fine prefiltration.
Can I sanitise with hot water instead of chemicals?
Only if the datasheet rates the membrane and seals for the temperature. Most polymeric UF membranes have a maximum temperature well below that used for thermal sanitisation, so chemical sanitising within limits is more common.
Can UF permeate from juice or whey be reused as water?
No. That permeate carries sugars or lactose and is a product or by-product stream. Water reuse applies to condensate, wash water and CIP rinses, often with UF followed by RO.
How high can the concentration factor go?
It depends on viscosity and solids. Juice is often taken to VCF 20 or more, with diafiltration to recover sugar. Protein concentrates are limited by retentate viscosity. Set the end point from pilot data.
How do I know when CIP is not working?
Compare clean water flux after each CIP with the first value on new membranes, at the same temperature and pressure. A loss that a full sequence does not recover points to a missed foulant such as protein, scale or biofilm.
Specification note: The figures in this article are typical engineering values and an illustrative worked example, not measurements from any plant. Flux, concentration factor and cleaning conditions depend on the product and must be confirmed by design and, where needed, a pilot. Food-contact suitability must be confirmed for each wetted material against the rules that apply to your plant. This is not a performance guarantee. See the product and datasheet disclaimer.