Silica in brackish RO: the recovery limit explained

2 hours ago
4 min read

The short answer

Silica does not respond to acid the way calcium carbonate does. Its solubility falls in cold water. So on high-silica water, silica sets the RO recovery, and the coldest month sets the design.

In the Theway Compass example below, borewell water carries 70 mg/L of silica. Keeping the concentrate within 150 % of silica saturation, a usual limit with a silica-specific antiscalant, the highest recovery is:

Feed temperature

With antiscalant (150 % of saturation)

Without antiscalant (100 %)

35 °C

67.5 %

51 %

25 °C

61 %

40 %

15 °C

52 %

below 40 %

At the 75 % recovery often assumed for brackish RO, the concentrate would be at 192 to 283 % of silica saturation, depending on temperature.

Why silica behaves differently

  • It is mostly uncharged. Below about pH 8.5, dissolved silica is mostly uncharged silicic acid. It does not form a salt with calcium or bicarbonate, so the acid dose that controls calcium carbonate scale does little for it.

  • Solubility falls in cold water. In the example concentrate, at about pH 7.9, amorphous silica dissolves to about 143 mg/L at 35 °C, 119 mg/L at 25 °C and 98 mg/L at 15 °C. A design that is safe in summer can scale in winter.

  • Solubility rises only at high pH. Above about pH 8, silica starts to ionise and its solubility climbs, steeply above pH 9. But at that pH calcium carbonate and magnesium salts scale unless the water has been fully softened.

  • Silica scale is hard to remove. Silica deposits respond poorly to the usual cleaning chemicals. Prevention, by the design limit, is the practical answer.

  • Metals make it worse. Iron and aluminium in the feed, often left over from coagulation, catalyse silica deposits well below saturation. Keep both below about 0.05 mg/L in the RO feed.

Theway Compass worked example

Basis: borewell water, 1,480 mg/L TDS, pH 7.6, with 70 mg/L SiO2, 90 mg/L Ca, 40 mg/L Mg, 420 mg/L HCO3 and 150 mg/L SO4. 50 m³/h of permeate from 6 × 6 + 3 × 6 Osmoflux LE TW 400 elements, with an antiscalant. Three years of membrane age. Recovery limits keep the same permeate flow and array.

Temperature

Highest recovery within 150 %

Feed flow

Silica in the concentrate

Silica solubility

Concentrate Langelier index

35 °C

67.5 %

74.1 m³/h

213 mg/L

143 mg/L

1.92

25 °C

61 %

82.0 m³/h

179 mg/L

119 mg/L

1.57

15 °C

52 %

96.2 m³/h

146 mg/L

98 mg/L

1.16

What the example shows:

  • The coldest month sets the recovery. Designing at 25 °C and running at 15 °C would put the concentrate well above the antiscalant limit. Size the intake, pretreatment and concentrate disposal for the cold-water recovery, or plan to lower the recovery in winter.

  • Calcium carbonate is not the limit here. The concentrate Langelier index stays within what an antiscalant normally handles at 25 and 15 °C and is high (1.92) at 35 °C, so confirm the dose with the antiscalant supplier. Silica still limits first.

  • pH barely moves the silica limit. At 25 °C, acid to pH 6.8 changes the silica-limited recovery from 61 % to 60 %. Caustic to pH 8.3 raises it only to 62 %, while the Langelier index climbs to 2.07. Neither is a silica remedy on this water.

  • Without an antiscalant, recovery falls a long way. At 25 °C it falls from 61 to 40 %. A silica-specific antiscalant is worth its cost here.

You can run this check on your own analysis in Theway Compass. When silica sets the limit, Compass names it in the design check and gives the highest recovery the design reaches within the limits.

What to do on high-silica water

  1. Design for the coldest feed. Enter the minimum and maximum temperatures. Compass checks silica saturation at each one.

  2. Use a silica-specific antiscalant. Confirm the allowed saturation with the supplier for your water and temperature. 150 % is a usual working figure, not a universal one.

  3. Lower the recovery, or accept a lower winter recovery. It is the simplest and surest remedy.

  4. Warm the feed if heat is available. Waste heat that lifts the feed from 15 to 25 °C raises the silica-limited recovery from 52 to 61 % in the example. Check the membrane temperature limit and the permeate quality in warm water.

  5. Remove silica ahead of the RO. Lime or magnesium oxide softening, or coagulation with a softening step, can cut silica substantially. It suits large plants and zero liquid discharge schemes.

  6. High-pH operation, only after full softening. Above about pH 10, silica is soluble and well rejected. But calcium and magnesium must first be removed almost completely, or they scale at once.

  7. Keep iron and aluminium out. Check the coagulant dose and residual metals in the RO feed.

Questions engineers ask

What silica level in the feed starts to matter?

It depends on the recovery and the temperature. In the example, 70 mg/L limits recovery to 52–67.5 %. At around 20–30 mg/L, typical brackish recoveries of 70–75 % are usually possible with an antiscalant. Run your own analysis rather than relying on a rule of thumb.

Does acid dosing help silica?

Very little. Acid controls calcium carbonate, but silica solubility is almost flat below pH 8. In the example it changes the limit by one point of recovery.

Why is my plant fine in summer but scaling in winter?

Silica solubility falls with temperature: from about 143 mg/L at 35 °C to 98 mg/L at 15 °C in the example concentrate. A recovery set in summer can exceed the limit in winter.

Can cleaning remove silica scale?

Only with difficulty. Silica deposits respond poorly to standard cleaning, so the design limit is what protects the elements. If you suspect silica scale, ask us about cleaning and element replacement.

Which Theway elements suit high-silica brackish water?

The element does not change the silica chemistry. Choose on flux, pressure and fouling. Low-energy Osmoflux LE TW 400 and fouling-resistant Osmoflux BFR TW 400 are common choices for borewell water. See the RO membranes range.

Specification note: The figures above are estimates from Theway Compass for the stated feed water and design basis, at three years of membrane age. They are for information only and are not a performance guarantee. Antiscalant limits vary by product and must be confirmed with the antiscalant supplier. Actual performance depends on the feed water, pre-treatment, operation and cleaning. See the product and datasheet disclaimer. Ask us for a quotation for your project.