Tubular UF for oily and high-solids wastewater

1 hour ago
6 min read

The short answer

  • Use tubular UF when the feed would block a hollow fibre. Free-flowing emulsions, sludge, leachate and produced water with several grams per litre of solids are the usual cases.

  • Tubes are typically 5 to 25 mm in inside diameter. The feed runs inside the tube and permeate passes outwards. The open channel tolerates solids and needs no fine prescreen.

  • Cross-flow velocity sets both flux and energy. Typical designs run at 2 to 5 m/s. Flux rises with velocity, but pumping energy rises faster.

  • Typical flux is 30 to 120 L/m²h, depending on the feed and the velocity. That is several times a hollow fibre on the same water, from a much more expensive square metre of membrane.

  • Expect regular cleaning. Oily feeds usually need an alkaline clean with surfactant every one to four weeks, plus an acid clean when scale or metal hydroxides build up.

Why tubular, and why the tube size matters

Hollow fibre UF, such as Stream UF, is the low-cost choice for river water, seawater pretreatment and tertiary effluent. It relies on backwashing to remove the cake. Feed it a machining coolant, a bilge water or a leachate with 15 g/L of biomass and the fibres clog, the oil smears the surface and backwashing no longer recovers the flux.

A tubular module works differently. The membrane is cast on the inside wall of a porous support tube, and the feed is pumped through the bore at high speed. Turbulence keeps the cake thin, so the module runs on cross-flow alone. The open bore passes particles that would plug a fibre bundle or a spiral spacer.

Tube diameter is a trade-off:

  • Small tubes (5 to 8 mm) pack more membrane area into a module and need less recirculation flow per square metre. They suit emulsions with fine solids.

  • Mid-size tubes (about 12 to 13 mm) are the common compromise for oily wastewater, MBR side streams and leachate.

  • Large tubes (about 25 mm) take fibrous or very concentrated feeds, but need roughly twice the recirculation flow of a 12.5 mm tube for each square metre of membrane.

As a rule, the recirculation flow per square metre of membrane scales with the tube diameter at a given velocity. At 4 m/s, one tube carries about 0.7 m³/h at 8 mm, 1.8 m³/h at 12.5 mm and 7.1 m³/h at 25 mm.

Tubeflux is Theway's tubular UF range for these duties. Check the Tubeflux datasheet for the tube diameter, membrane material, pressure, temperature, pH and cleaning limits of the module you select.

Cross-flow velocity, flux and pumping energy

The pump does two jobs in a tubular loop: it sweeps the membrane surface and it supplies the transmembrane pressure. Typical values:

Parameter

Typical range

Cross-flow velocity

2 to 5 m/s (2 to 3 m/s for low-solids emulsions, 4 to 5 m/s for sludge and leachate)

Loop inlet pressure

2 to 6 bar

Average transmembrane pressure

1 to 4 bar

Flux, oily emulsions

30 to 100 L/m²h

Flux, side-stream MBR and leachate

50 to 120 L/m²h

Recirculation pumping energy

2 to 6 kWh/m³ permeate

Permeate taken per pass

1 to 5 % of the recirculated flow

Pressure drop along a tube rises with velocity to roughly the power 1.75, and the recirculated flow rises in direct proportion. So pumping power goes up with roughly the cube of velocity, while flux usually rises much more slowly. Past a point, the extra velocity buys little flux at a high energy cost.

Free oil changes the picture. Tubular UF handles emulsified oil well, but a layer of free oil coats the membrane and drops flux sharply. Remove free oil first by skimming, an oil separator or dissolved air flotation.

Worked example: a 10 m³/h oily wastewater plant

Basis (illustrative): 10 m³/h of permeate from an emulsified oily wastewater after free-oil removal. 12.5 mm tubes, 3 m long. Each loop has four modules in series, each with 19 tubes in parallel, giving 8.95 m² per loop and a 12 m flow path. Pump efficiency 70 %, fittings add 15 % to the tube pressure drop. The flux at each velocity is an assumed typical value, not a test result.

Cross-flow velocity

3 m/s

4 m/s

5 m/s

Flux (typical, assumed)

60 L/m²h

80 L/m²h

95 L/m²h

Permeate per loop

0.54 m³/h

0.72 m³/h

0.85 m³/h

Loops needed

19

14

12

Membrane area

170 m²

125 m²

107 m²

Recirculation per loop

25 m³/h

34 m³/h

42 m³/h

Loop pressure drop

1.1 bar

1.9 bar

2.8 bar

Recirculation pump power, total

21 kW

35 kW

55 kW

Recirculation energy

2.1 kWh/m³

3.5 kWh/m³

5.5 kWh/m³

Going from 3 to 5 m/s cuts the membrane area by about 37 % but more than doubles the energy, so many oily-water plants settle near 3 to 4 m/s. Sludge and leachate usually need the higher end to hold flux and avoid settling. About 2 % of the recirculated flow leaves as permeate per pass, which is normal for a tubular loop.

Run your own numbers in Theway Compass, and use the UF sizing calculator for the area check.

Cleaning tubular UF

Cross-flow keeps the cake thin, but oil, biofilm and scale still build up. Typical practice:

  • Trigger: clean when permeability at 20 °C, at the same velocity, falls 20 to 30 % from the post-clean value, or when the loop pressure drop rises about 15 %. See RO and UF normalisation.

  • Flush first: displace the concentrate with permeate or clean water so the chemicals meet the membrane, not the bulk sludge.

  • Alkaline clean for oil and organics: caustic at pH 11 to 12 with a compatible surfactant, typically at 35 to 50 °C, recirculated for 30 to 60 minutes. Warm cleaning matters with oil; cold solutions leave a film.

  • Acid clean for scale and metals: citric or nitric acid at around pH 2, when hardness, iron or aluminium are present.

  • Oxidant only if allowed: hypochlorite can restore biofouled modules, but the dose and contact time must stay within the membrane limits.

  • Foam balls: some larger tube designs allow sponge balls to be passed through the bore to scrub the wall. Use them only where the module design permits it.

Check the limits on the membrane cleaning limits page and the Tubeflux datasheet before setting pH, temperature or oxidant dose.

What to do

  1. Characterise the feed. Measure free and emulsified oil, suspended solids, hardness, iron and temperature over a normal week, not a single grab sample.

  2. Remove free oil and coarse solids. Skim or float the free oil, and screen out rags, swarf and grit before the loop.

  3. Pick the tube size for the solids: mid-size for most oily and MBR duties, large for fibrous or very concentrated feeds.

  4. Choose the velocity by comparing area and energy, as in the worked example. Start near 3 to 4 m/s for emulsions and 4 to 5 m/s for sludge.

  5. Size conservatively. Use the lower half of the typical flux range unless pilot data support more.

  6. Plan cleaning from day one. Fit a heated clean-in-place tank, a permeate flush and permeability logging.

  7. Pilot when the feed is unusual. A short pilot settles flux and cleaning frequency better than any table. Send us an enquiry.

Questions engineers ask

Why not use hollow fibre UF with better pretreatment?

For dilute, stable feeds you often can, and it costs less. When oil and solids vary or reach grams per litre, the pretreatment needed to protect fibres becomes a plant of its own. Tubular UF accepts the feed largely as it is.

Can tubular UF treat produced water?

Yes, after free-oil removal it is a common polishing step ahead of reinjection or further treatment. See produced water membranes.

Is tubular UF used for landfill leachate?

Yes, mainly as the separation stage of a side-stream MBR, often followed by RO. See landfill leachate membranes and membrane bioreactors.

How much can the concentrate be thickened?

It depends on viscosity. Oily emulsions are often concentrated until the oil content reaches several per cent. Flux falls and pressure drop rises as the concentrate thickens, so set the end point from pilot data or a conservative design value.

Are ceramic tubes better?

Ceramic tubes tolerate higher temperatures, stronger chemicals and solvents, but cost more. Polymeric tubes are usually the economic choice when temperature and chemistry are within their limits. Theway supplies both.

Does a higher velocity always mean less fouling?

Up to a point. Beyond about 5 m/s the gain in flux is usually small and the pumping energy, wear and heat input climb quickly.

Specification note: The figures in this article are typical engineering values and an illustrative worked example, not measurements from any plant. Flux, energy and cleaning frequency depend on the feed and must be confirmed by design and, where needed, a pilot. Compass results are estimates for information only and are not a performance guarantee. See the product and datasheet disclaimer.