top of page

Ultrafiltration in refineries: river water, effluent reuse and MBR

Nov 12
2 min read

Updated: 5 hours ago

At a glance: refineries use UF in three places: on river water ahead of the RO and DM plant that makes boiler feed, on treated refinery effluent ahead of RO for reuse, and as MBR in the effluent treatment plant itself. Oil is the main hazard: free oil must be removed upstream, and cleaning chemistry must handle traces that reach the membrane.

Ultrafiltration in refineries: river water, effluent reuse and MBR

Where UF and MBR fit

Duty

Water

Technology

Boiler feed and utilities

River water

UF ahead of RO and DM

Water reuse

Treated refinery effluent

UF ahead of RO

Effluent treatment

Refinery wastewater after oil removal

MBR in place of the secondary clarifier

Theway in refineries

Design points for refinery water

  • Oil removal upstream. API separators, flotation and walnut-shell or media filters remove free and emulsified oil before the membrane. Ask us for the oil and grease limit for your module.

  • Fibre material. PVDF tolerates oxidants and a wide cleaning range; we recommend per stream.

  • Cleaning. Alkaline CEB and CIP handle oil traces and organics; acid cleaning handles scale and iron.

  • Variable quality. Refinery effluent changes with crude slate and unit upsets; design flux should allow for it.

  • Existing plants. Many refinery UF plants run imported modules. Supraflux and Puran Max are direct retrofits for Hyflux and Hydranautics modules.

Checklist

  • Oil and grease levels at UF inlet, including upsets

  • COD, TSS and turbidity trends

  • Oil removal stages reviewed

  • Cleaning chemistry for oil and organics

  • Retrofit option checked for existing UF

  • MBR considered for ETP upgrades

Questions buyers ask

Can UF remove oil?

UF retains emulsified oil droplets, but oil fouls the membrane quickly. Remove free oil upstream; UF is the polishing stage.

Is MBR suitable for refinery effluent?

Yes, after oil removal. A refinery in Central India runs Surge MBR membranes in its ETP. See hollow fibre MBR and Surge 500T.

How does produced water differ?

Produced water from oil and gas fields carries more oil and salt. See produced water treatment with UF and MBR.

Talk to us about your refinery

Send your water data through Send Enquiry or to mail@thewaymembranes.com.

Related: see the ultrafiltration (UF) range and size your plant in Theway Compass.