Ultrafiltration in refineries: river water, effluent reuse and MBR
Updated: 5 hours ago
At a glance: refineries use UF in three places: on river water ahead of the RO and DM plant that makes boiler feed, on treated refinery effluent ahead of RO for reuse, and as MBR in the effluent treatment plant itself. Oil is the main hazard: free oil must be removed upstream, and cleaning chemistry must handle traces that reach the membrane.

Where UF and MBR fit
Duty | Water | Technology |
|---|---|---|
Boiler feed and utilities | River water | UF ahead of RO and DM |
Water reuse | Treated refinery effluent | UF ahead of RO |
Effluent treatment | Refinery wastewater after oil removal | MBR in place of the secondary clarifier |
Theway in refineries
Supraflux UF at a refinery in Eastern India: river water pre-treatment ahead of RO and the DM plant
Puran Max UF at a refinery in North India: treated refinery effluent ahead of RO
Surge MBR at a refinery in Central India: effluent treatment plant
Design points for refinery water
Oil removal upstream. API separators, flotation and walnut-shell or media filters remove free and emulsified oil before the membrane. Ask us for the oil and grease limit for your module.
Fibre material. PVDF tolerates oxidants and a wide cleaning range; we recommend per stream.
Cleaning. Alkaline CEB and CIP handle oil traces and organics; acid cleaning handles scale and iron.
Variable quality. Refinery effluent changes with crude slate and unit upsets; design flux should allow for it.
Existing plants. Many refinery UF plants run imported modules. Supraflux and Puran Max are direct retrofits for Hyflux and Hydranautics modules.
Checklist
Oil and grease levels at UF inlet, including upsets
COD, TSS and turbidity trends
Oil removal stages reviewed
Cleaning chemistry for oil and organics
Retrofit option checked for existing UF
MBR considered for ETP upgrades
Questions buyers ask
Can UF remove oil?
UF retains emulsified oil droplets, but oil fouls the membrane quickly. Remove free oil upstream; UF is the polishing stage.
Is MBR suitable for refinery effluent?
Yes, after oil removal. A refinery in Central India runs Surge MBR membranes in its ETP. See hollow fibre MBR and Surge 500T.
How does produced water differ?
Produced water from oil and gas fields carries more oil and salt. See produced water treatment with UF and MBR.
Talk to us about your refinery
Send your water data through Send Enquiry or to mail@thewaymembranes.com.