When to clean RO and UF: reading normalised data
The short answer
Do not judge membranes on raw readings. Normalise them to the start-up conditions: for RO, normalised permeate flow, salt passage and pressure drop; for UF, permeability at 20 °C.
Clean on the usual triggers:
RO: normalised permeate flow down 10 %, salt passage up 10 % or pressure drop up 15 %.
UF: permeability at 20 °C down 30 %.
Use the trend since the last clean to plan the next one. In the RO example below, the trend gives about 25 days of warning. In the UF example it gives about 14 days.
Check every clean. Compare the normalised value just before and just after. A clean that restores less than about half of the loss means the chemistry, the temperature or the pretreatment needs attention.
Why raw readings mislead
Warm water lets more water through the membrane. So a plant can produce more while it fouls.
In the RO example, the feed warmed from 26 to 30 °C over the first two months. The permeate flow rose from 50 to 54 m³/h at the same feed pressure. Yet normalised permeate flow had already fallen 3.8 %. Read raw, the plant looked healthy. Normalised, it was fouling at a steady rate from the first week.
The same happens in reverse in winter: cold water lowers the flow and raises the pressure, and a clean plant can look fouled.
RO worked example
Basis: an illustrative brackish RO train with a design permeate flow of 50 m³/h. Feed 1,500 mg/L at 12 bar, concentrate 17 m³/h. Readings every 14 days for nine months, with the feed between 22 and 30 °C. The first reading is the baseline.
Reading | Temperature | Permeate flow (raw) | Normalised permeate flow | Normalised salt passage | Normalised pressure drop |
|---|---|---|---|---|---|
Baseline | 26.0 °C | 50.0 m³/h | 0 % | 0 % | 0 % |
Week 8 | 29.9 °C | 54.0 m³/h | −3.8 % | +3.0 % | +3.2 % |
Week 22, before the clean | 24.0 °C | 42.5 m³/h | −10.4 % | +8.3 % | +8.8 % |
Week 24, after the clean | 23.0 °C | 44.5 m³/h | −2.6 % | +4.1 % | +3.5 % |
Week 36, latest | 24.9 °C | 44.6 m³/h | −8.3 % | +8.6 % | +8.3 % |
What Compass reads from it:
The clean was needed at week 22. Normalised flow had reached the −10 % trigger.
The clean worked. It restored 75 % of the lost permeate flow, from −10.4 % to −2.6 %.
The next clean is due in about 25 days. Since the clean, normalised flow has fallen about 2.0 % a month. At that rate it reaches −10 % around 25 days after the latest reading. Salt passage reaches +10 % at almost the same time, so the next clean should be planned for then. Pressure drop is further off, at about 118 days.
UF worked example
Basis: an illustrative river-water UF rack with 24 Stream TW 250/1650 modules (1,920 m²). It makes 100 m³/h of filtrate, a flux of 52.1 L/m²·h. Weekly readings over twelve weeks, taken just after a backwash, with the water cooling from 28 to 24 °C. Permeability is the flux divided by the transmembrane pressure, corrected to 20 °C for the viscosity of water.
Reading | Temperature | Pressure | Permeability at 20 °C | Change from baseline |
|---|---|---|---|---|
Baseline | 28.0 °C | 0.197 bar | 220 L/m²·h·bar | 0 % |
Week 7, before the clean | 25.5 °C | 0.295 bar | 155 | −29.4 % |
Week 8, after the clean | 25.2 °C | 0.219 bar | 210 | −4.2 % |
Week 12, latest | 23.8 °C | 0.275 bar | 173 | −21.2 % |
What Compass reads from it:
The chemical clean (CIP) at week 7 restored 86 % of the lost permeability.
The next CIP is due in about 14 days. Permeability is falling about 18 % a month, so it reaches the −30 % trigger around two weeks after the latest reading.
Pressure alone would not have warned you. At 0.275 bar, the pressure is far below the module's 1 bar limit. At its current trend it would take about 260 days to reach 80 % of that limit. The permeability trend shows the fouling months earlier.
What a weak clean tells you
When a clean restores less than about half of the loss, Compass says so and suggests what to change:
RO:
high-pH cleaning for organic and biological fouling;
low-pH cleaning for scale and metal oxides;
cleaning at the supplier's temperature limit;
an element autopsy if the loss stays.
UF:
an acid step for iron, manganese or scale;
a caustic and hypochlorite step for organic and biological fouling;
a check of the coagulant dose.
A loss that no clean restores, such as half the UF permeability or a quarter of the RO flow, points to irreversible fouling or damage. Plan for replacement elements or modules.
How to do it in Theway Compass
Open Normalise plant data and choose RO or NF, or UF or MF.
Paste your readings from a spreadsheet. For RO: date, pressures, flows, TDS or conductivity, temperature. For UF: date, filtrate flow, transmembrane pressure, temperature. Then pick the UF module and the number in service.
Read the advice, the Cleaning outlook (days to each trigger, from the trend since the last clean) and the list of cleans found in the data, each with the share of the loss it restored.
Download the PDF report or the CSV for your records.
Try it in Theway Compass.
Questions operators ask
How often should I take readings?
Daily, or at least weekly, at the same point in the cycle. For UF, that means just after a backwash. More readings give a steadier trend and an earlier warning.
Which reading is the baseline?
The first stable days after start-up, or after new membranes. Keep it fixed. Re-basing after each clean hides the slow loss that cleaning does not recover.
Why do you use the trend since the last clean?
A clean resets the fouling. The rate after it is what decides the next one.
My plant shows more permeate in summer. Is that good?
Not necessarily. Warm water raises the raw flow, so check the normalised flow. In the RO example, raw flow rose 8 % while normalised flow fell 3.8 %.
Can Theway help when cleaning no longer restores performance?
Yes. Send us your normalised data and we will advise on cleaning, element autopsy or replacement Osmoflux elements and Stream UF modules.
Note: The data in this article are illustrative, built to show the method. They are not measurements from any plant. Cleaning triggers are the usual industry values; follow the membrane supplier's cleaning instructions and limits for your elements. Compass results are estimates for information only and are not a performance guarantee. See the product and datasheet disclaimer.