Seawater RO elements: choosing MR, PRO, ES or HB
The short answer
All Osmoflux MR elements are 8-inch seawater RO elements in the same shell. The variants trade the same three things against each other: feed pressure, salt passage and boron passage. You cannot have all three at their best in one element.
Variant | What it is for | What you give up |
|---|---|---|
MR (standard) | General seawater duty with a balance of pressure and rejection | Nothing in particular; the reference point |
MR PRO | Lower salt and boron passage than standard, at moderate extra pressure; often used in the lead positions | Some feed pressure |
MR ES (energy-saving) | Lower feed pressure on cooler or lower-salinity seawater | Higher salt and boron passage |
MR HB (high-boron) | Tight boron limits, typically 1 mg/L, on warm seawater | The most feed pressure |
Three rules cover most choices:
Start from the boron limit at the hottest feed, not from TDS. On warm seawater, boron usually decides the element before salt does.
Use ES only where there is boron and TDS margin to spare, typically on cooler water or where the product is blended or polished.
Size the high-pressure pump for the coldest case if you choose HB, because pressure rises as the water cools.
The published figures
The current Osmoflux seawater range publishes these standard-test figures:
Element | Permeate flow (gpd) | Stabilised salt rejection | Note |
|---|---|---|---|
Osmoflux MR TW 300 | 6,000 | 99.1 % | Tested at 800 psi |
9,000 | 99.8 % | Standard seawater element | |
7,000 | 99.8 % | Tighter membrane, lower flow at test | |
9,900 | 99.8 % | Higher flow in the same 8040 format | |
MR TW 400 ES, MR TW 440 ES | On request | On request | Energy-saving variants |
MR TW 400 HB | On request | On request | High-boron variant |
Datasheet figures are measured at standard test conditions, which for seawater elements are typically about 32,000 mg/L sodium chloride, 25 °C, 800 psi (55 bar) and 8 % recovery. A plant runs at different salinity, temperature and recovery, so the datasheet tells you how elements compare, not what your permeate will be. Rejection of boron is not part of the standard salt test and must be checked separately.
Note what the PRO figures show. Its flow at test is lower than the standard MR TW 400 at the same headline rejection. That is the trade in action: a tighter polyamide layer passes less salt and boron per unit of water, so it needs more driving pressure for the same flux. The MR TW 440 goes the other way: more flow at the same rejection, which lets you take the same output at lower average flux or more output from the same number of vessels.
When boron sets the choice
Seawater carries about 4.5–6 mg/L of boron, mostly as uncharged boric acid at normal seawater pH. Polyamide membranes reject it far less well than salt, and its passage climbs steeply with temperature. That is why boron, not TDS, usually decides the element on warm seawater.
Typical limits are:
Drinking water, WHO guideline: 2.4 mg/L. A standard single pass usually complies.
Drinking water, many project specifications: 1.0 mg/L. On warm water this usually needs a high-boron element.
Irrigation of sensitive crops: 0.3–0.5 mg/L. This usually needs a partial second pass at raised pH, even with HB elements.
Two effects matter in design:
Temperature. In the Gulf example below, boron rejection of the standard train falls from 79 % at 22 °C to 64 % at 35 °C. Design boron at the hottest feed.
pH. Raising feed pH converts more boric acid to borate, which is rejected well. At seawater concentration, calcium carbonate scale limits how far the first pass can be raised, so pH is a second-pass tool. See our post on boron removal and second passes for that route.
Worked example: the same train with different elements
Basis (illustrative, Theway Compass estimates): the train from our Gulf seawater pressure, boron and recovery post: 45,000 mg/L TDS, 5.5 mg/L boron, pH 8.1, 35 °C, 40 % recovery, 200 m³/h of permeate, 47 vessels × 7 elements, three years membrane age, with energy recovery.
Element configuration | Feed pressure (bar) | Permeate TDS (mg/L) | Boron (mg/L) | Specific energy (kWh/m³) |
|---|---|---|---|---|
7 × MR TW 400 (standard) | 64.9 | 457 | 1.99 | 2.80 |
2 × MR TW 400 PRO lead + 5 × MR TW 400 | 66.1 | 426 | 1.89 | 2.84 |
7 × MR TW 400 PRO | 69.9 | 345 | 1.61 | 2.97 |
7 × MR TW 400 HB | 74.8 | 272 | 0.96 | 3.19 |
What the table says:
Against a 2.4 mg/L WHO limit, the standard train complies at 35 °C with the lowest pressure and energy. Nothing tighter is needed.
PRO in the lead positions trims salt and boron and brings the lead-element flux down, at about 1.2 bar extra. It is a useful fix where the lead element runs above flux guidelines, but it does not reach 1 mg/L.
Only the HB train meets 1 mg/L at 35 °C in a single pass, at about 10 bar and 0.39 kWh/m³ more than standard.
Check the cold case. At 22 °C the same HB train gives 0.49 mg/L boron but needs 78.6 bar, within the 83 bar element rating. The pump must be sized for that, not for the summer case.
Where ES fits. The energy-saving variants go the other way from HB: lower feed pressure, higher salt and boron passage. On this warm, salty Gulf basis with a 1 mg/L boron limit, ES would move boron further from the target, so it is not the right choice. ES earns its place where the feed is cooler or less saline, where the boron limit is 2.4 mg/L or where permeate is polished in a second pass anyway. In those cases a few bar of feed pressure saved across the year is worth more than salt and boron margin you do not need. Run your own feed through Theway Compass with ES and HB elements side by side to see the difference at your hottest and coldest temperatures; ES and HB figures are available on request.
Mixing elements in one vessel
Hybrid vessels are common in seawater RO. The lead elements see the highest net driving pressure and the highest flux, so a tighter element there (PRO or HB) limits lead-element flux and salt passage. The tail elements see the lowest driving pressure, so a more open element there (standard or ES) keeps them producing. Two practical points:
Project the hybrid as built, element by element. Averages hide where the flux and boron come from.
Keep a record of position by serial number, so replacement elements go back to the same duty.
What to do
Fix the limits first: boron and TDS in the product, as a maximum or an average, at the hottest and coldest feed temperatures.
Run the standard MR TW 400 train in Theway Compass at both temperatures. This is the reference.
If boron fails at the hottest feed, try PRO in the lead positions, then a full PRO train, then HB. Stop at the lightest option that passes with margin.
If boron and TDS have plenty of margin, try ES elements, or ES in the tail positions, and compare feed pressure and specific energy.
Check the coldest case for feed pressure against the 83 bar element rating and the pump curve.
Check the lead-element flux against the guideline for your pre-treatment and SDI.
If boron still fails with HB, plan a partial second pass at raised pH rather than pushing recovery or pressure.
Send an enquiry with your feed analysis, temperatures and limits for ES and HB datasheets.
Questions engineers ask
Is PRO just a higher-rejection version of the standard element?
Broadly, yes. It is a tighter membrane with lower salt and boron passage and lower flow at the same test pressure. On a full train it costs about 5 bar in the Gulf example; in the lead positions alone it costs about 1 bar.
Can ES elements meet a 1 mg/L boron limit?
Not usually on warm seawater in a single pass. ES trades rejection for pressure. Where ES is used and boron is tight, a partial second pass normally takes care of boron.
Does HB need a different pressure vessel?
No. All Osmoflux MR elements are the standard 8040 size. Check that the vessels, piping and pump are rated for the highest feed pressure in the cold case.
Why does the MR TW 300 show lower rejection?
It is a lower-flow element with a published 99.1 % rejection at 800 psi. It suits smaller or lower-pressure duties. For drinking water from typical seawater, the MR TW 400 or 440 family is the usual starting point.
Should I use 400 or 440 elements?
The MR TW 440 gives more flow at the same rejection. Use it to lower average flux on a difficult feed, or to get more output from existing vessels. Check lead-element flux, which rises if you keep the same feed flow.
Can I replace a few elements with a different variant?
Yes, if the new elements are projected in their actual positions. A tighter element added in the lead shifts flux towards the tail. Project before you buy.
Specification note: figures in this post are typical or illustrative values and Theway Compass estimates for the stated basis. They are not a performance guarantee. Actual performance depends on feed water, pre-treatment, temperature, recovery, membrane age and operation. See the product and datasheet disclaimer.