The short answer

In a zero liquid discharge (ZLD) plant, the primary RO reject usually goes to a thermal evaporator, the most energy-intensive step in the train. Its size is set by the volume of water it must boil off.

High-pressure disc tube RO can take that reject and remove more water as a membrane step, before the evaporator. Two things decide how far you can go:

  1. Osmotic pressure. The concentrate TDS you can reach is capped by the pressure class of the module. Theway's Discflux range comes in DT 75, DT 90, DT 120 and DT 160 bar classes. As a rough guide, these map to concentrate ceilings of about 60,000, 80,000, 110,000 and 150,000 mg/L TDS (sodium chloride basis).

  2. Scaling. RO reject is already close to saturation for calcium carbonate, calcium sulphate and silica. In many plants, scaling sets the recovery limit before pressure does.

Disc tube RO removes water, not salt. The salt load to the crystalliser stays the same; what shrinks is the volume the evaporator must handle.

Pressure class and concentrate TDS

The feed pressure has to cover the osmotic pressure of the concentrate leaving the stage, plus net driving pressure, pressure drop and a fouling and salinity allowance. For brine duty we take those extras together as about 20 to 30 bar.

At seawater strength, osmotic pressure rises by about 0.75 bar per 1,000 mg/L of sodium chloride. In stronger brines it climbs towards 0.85 to 0.9 bar, so each step up in pressure buys a little less extra concentration.

Discflux class

Maximum operating pressure

Concentrate osmotic pressure ceiling (typical, after 20 to 30 bar margin)

Approximate concentrate TDS ceiling (NaCl basis, illustrative)

DT 75

75 bar

about 45 to 55 bar

about 60,000 mg/L

DT 90

90 bar

about 60 to 70 bar

about 80,000 mg/L

DT 120

120 bar

about 90 to 100 bar

about 110,000 mg/L

DT 160

160 bar

about 130 to 140 bar

about 150,000 mg/L

Two cautions on this table:

  • Composition matters. Per milligram, sodium sulphate gives a lower osmotic pressure than sodium chloride, so a sulphate-rich textile brine can reach a higher TDS in the same class. Work from a full ion analysis, not TDS alone.

  • Do not design to the ceiling. Effluent RO reject drifts with production and season. Leave headroom for the saltiest week of the year.

Why open-channel disc modules suit brine

RO reject in a ZLD plant is supersaturated with scalants held in check by antiscalant, and it carries silica and concentrated organics. In a spiral-wound element, scale and deposits catch on the feed spacer, pressure drop rises, and cleaning reaches the blocked zones poorly.

A Discflux module stacks flat membrane cushions between hydraulic discs, with a short, open feed channel and no spacer. For brine duty this matters in three ways:

  • Short residence time. Scalants need time to form crystals. A high-velocity recirculation loop and short flow paths keep the brine moving through the supersaturated zone quickly.

  • Nothing for crystals to anchor on. Deposits stay on the open membrane surface, where an acid clean can reach them.

  • Serviceable modules. A stack can be opened and individual cushions replaced, which suits a duty where an upset can scale part of a module.

Leachate, the other classic disc tube duty, is mainly an organic fouling problem; RO reject is mainly a scaling problem. See disc tube RO for landfill leachate.

Antiscalant and pH strategy

Scaling control for the disc tube stage is set separately from the primary RO. Do not rely on the antiscalant left over from upstream.

  • Re-dose antiscalant ahead of the disc tube feed, sized for the much higher concentration factor. Choose a product rated for the limiting scalant (carbonate, sulphate or silica). Check that it is compatible with the evaporator downstream, because phosphonate-based products can affect thermal scaling and foaming.

  • Acidify for carbonate. A feed pH of about 6 to 6.5 is typical to keep calcium carbonate under control. Hydrochloric acid avoids adding sulphate; sulphuric acid adds to the calcium sulphate risk.

  • Watch silica. Without a silica-specific antiscalant, the usual working limit in the concentrate is about 120 to 150 mg/L at 25 °C. With one, typical vendor limits are higher, but silica often still caps recovery. Silica solubility rises with temperature, so a warm brine helps.

  • Consider softening or NF. Where calcium, barium or silica limit recovery, a softening step (lime, ion exchange or nanofiltration) between the primary RO and the disc tube stage can raise the achievable recovery considerably.

  • No oxidants. The polyamide membrane must not see free chlorine.

  • Flush on every stop. Displace the brine with permeate at every shutdown; supersaturated concentrate left standing will precipitate.

Worked example: evaporator feed volume (illustrative)

A textile or chemical effluent plant runs its primary RO (for example on Osmoflux BFR or LF elements) at 1,000 m³/d of feed, 3,000 mg/L TDS and 75 % recovery. The reject is 250 m³/d at about 12,000 mg/L and carries about 3,000 kg/d of dissolved salt. We assume near-complete salt rejection and ignore the small amount of salt that passes into the permeate. The figures are rounded mass-balance values, not a design and not a savings claim.

Scheme

Disc tube recovery on reject (overall)

Evaporator feed volume

Evaporator feed TDS (approx.)

Typical feed pressure

Discflux class

A. Reject straight to evaporator

none

250 m³/d

12,000 mg/L

none

none

B. One disc tube stage

75 %

62.5 m³/d

48,000 mg/L

55 to 65 bar

DT 75

C. Two stages in series

75 % then 50 % (87.5 %)

about 31 m³/d

about 96,000 mg/L

100 to 110 bar on stage 2

DT 75 then DT 120

D. Two stages, high-pressure tail

75 % then about 63 % (about 91 %)

about 23 m³/d

about 130,000 mg/L

135 to 145 bar on stage 2

DT 75 then DT 160

What the mass balance shows:

  • The salt load to the crystalliser is about 3,000 kg/d in every scheme. Disc tube RO changes how much water arrives with it.

  • Scheme B cuts the evaporator feed by three quarters. C and D go further, at much higher pressure and with tighter scaling control.

  • Scheme D sits close to saturation for sodium sulphate and calcium sulphate in many brines. Check every scalant at 130,000 mg/L before choosing it. Where scaling governs, scheme C with a softening step is often the more robust choice.

  • The disc tube permeate (typically a few hundred to about 1,000 mg/L TDS) is usually returned to the primary RO feed or blended with its permeate, so that the plant keeps the water it has recovered.

What to do

  1. Get the primary RO reject analysis. Run the primary RO in Theway Compass at its real recovery to get the full ion profile of the reject, and confirm it with a lab analysis that includes silica, barium, strontium, fluoride and COD.

  2. Fix the evaporator feed target (TDS and volume) with the thermal designer.

  3. Check scaling at each candidate recovery. Calcium carbonate, calcium sulphate, barium sulphate, silica and, in sulphate brines, sodium sulphate itself.

  4. Decide on softening or NF if scaling caps recovery below the target.

  5. Choose the Discflux class with headroom. DT 75 or DT 90 for a first stage on reject, DT 120 or DT 160 for a tail stage.

  6. Plan cleaning and flushing. Acid cleans for scale, alkaline cleans for organics, within the membrane cleaning limits. Track normalised flux and pressure and clean on the trend, not the calendar.

  7. Send the analysis through Send enquiry for a Discflux configuration review. See also the textile ZLD page.

Questions engineers ask

Why not send the RO reject straight to the evaporator?

You can, and small plants often do. Concentrating it first reduces the volume the evaporator must handle. Whether that is worthwhile depends on plant scale, brine chemistry and the operating cost of each step.

Does disc tube RO reduce the salt going to the crystalliser?

No. It removes water; the salt arrives in a smaller, more concentrated stream.

What usually limits recovery, pressure or scaling?

In RO reject, scaling more often than pressure. Silica and calcium sulphate are the common limits. Softening or NF ahead of the disc tube stage can lift that limit.

Can a high-pressure spiral-wound element do this job?

On a clean, softened brine at moderate concentration, sometimes. On a supersaturated reject with organics and silica, the spacer channel tends to scale faster and is harder to clean back.

Where does the disc tube permeate go?

Usually back to the primary RO feed tank, or blended with primary RO permeate if quality allows.

How often does a brine disc tube stage need cleaning?

Weekly to monthly acid cleans are typical on difficult duties. Set the interval from normalised data.

Specification note: the osmotic pressures, TDS ceilings, feed pressures, recoveries and mass-balance figures in this post are typical or illustrative engineering values for discussion, not a performance guarantee. Actual design depends on the full brine analysis, pretreatment and operating conditions. See the product and datasheet disclaimer.