Flat sheet or hollow fibre MBR: how to choose
Updated: 11 hours ago
At a glance: both flat sheet and hollow fibre MBR membranes sit submerged in activated sludge and draw permeate by suction. Flat sheet panels are robust, easy to inspect and tolerant of high mixed liquor solids, but take more tank space. Hollow fibre modules pack more area into the tank and can be backwashed, but need finer screening. Reinforced hollow fibre, such as Surge 500T, adds strength for large plants.

Side by side
Feature | Flat sheet MBR | Hollow fibre MBR | Reinforced hollow fibre |
|---|---|---|---|
Theway product | |||
Membrane | Flat sheet panels | Reinforced PVDF, about 0.04 µm | Reinforced PVDF, 0.04 µm |
Module or cassette size | Cassettes for 15 to 500 KLD | 10, 13, 20, 34 and 40 m² modules | Same size as ZeeWeed 500D |
Mixed liquor solids | Up to 18,000 mg/L | Per design | Per design |
TMP | Up to 20 kPa | Suction | −55 to 55 kPa |
Temperature | 5 to 40 °C | Up to 45 °C | Up to 40 °C |
pH | 5 to 10 | Per design | 5 to 9.5 |
Backwash | Usually relaxation instead | Yes | Yes |
Frame | SS 304, 316 or 316L | Per design | Cassette |
How to choose
Flat sheet suits small and medium STPs, sites where operators prefer to lift panels and inspect them, and plants with variable loads or less reliable screening.
Hollow fibre suits plants where tank volume is tight, larger flows, and operators comfortable with fine screening and automated backwash.
Reinforced hollow fibre (Surge 500T) suits large municipal and industrial plants and replacements of ZeeWeed 500D modules in existing cassettes. See replacing ZeeWeed MBR membranes.
Common to both
Screening matters. Hair and fibres wrap around membranes. Hollow fibre needs especially fine screening.
Aeration scours the membrane. Blowers and diffusers are part of the membrane system.
Design flux is low. Submerged modules run under suction, so flux sits well below pressurised UF; the TW-MBR design figure depends on site conditions.
Chemical cleaning in place, with hypochlorite and acid within the membrane limits. The TW-MBR catalogue gives a typical maintenance clean of 1 to 1.5 h and a recovery clean of 10 to 12 h, about every two weeks.
In service
Surge MBR membranes treat wastewater at a healthcare facility in South India, the integrated steel plant in Central India, a beverage plant in Sangareddy and a refinery in Central India.
Checklist
Flow and load, including peaks
Tank volume available
Screening standard ahead of the MBR
Operator preference for inspection or automation
Existing cassettes, if replacing
Questions buyers ask
Which uses less energy?
It depends more on the aeration design and flux than on membrane type. Compare complete designs.
Can flat sheet membranes be backwashed?
Most flat sheet MBR designs use relaxation and chemical cleaning instead of backwash.
Which is better for a 100 KLD apartment STP?
Both work. Flat sheet cassettes are a common choice at that size for ease of inspection.
Choose your MBR
Send flow, load and tank details through Send Enquiry or to mail@thewaymembranes.com.
Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.