Replacing submerged MBR modules by brand: PURON, MemPulse, HYDRAsub, BIO-CEL, Membray, Memcor, ZeeWeed
Updated: 11 hours ago
At a glance: Theway makes submerged membrane modules to the dimensions and connections of the common MBR and submerged UF makes, so a plant keeps its cassettes, headers, scour piping and controls and changes only the modules. The table below lists the Theway module for each original make. For the ZeeWeed 500D family see the Surge 500T page; for Kubota and Mitsubishi flat sheet see this guide.
Theway module by original make
Original make and series | Theway module | Type |
|---|---|---|
Koch PURON | Reinforced hollow fibre | |
DuPont MemPulse | Reinforced hollow fibre | |
Hydranautics HYDRAsub | Hollow fibre, 25 and 40 m² | |
MANN+HUMMEL BIO-CEL | Flat sheet | |
Toray Membray | Flat sheet, 1.4, 0.9 and 0.7 m² | |
Memcor S10V and S10N | Submerged UF hollow fibre | |
Veolia ZeeWeed 500D modules | Reinforced hollow fibre, 30, 34 and 40 m² | |
Veolia ZeeWeed 500D cassettes | Complete cassettes of 48 and 16 | |
Veolia ZeeWeed 500EV | Cassette | |
Veolia ZeeWeed 1000 | Submerged UF | |
Kubota SP and Type 510/515 | Flat sheet | |
Mitsubishi 5000 and 5600 series | Hollow fibre |
Each product page carries the datasheet. The full cross-reference, including UF rack modules and RO elements, is on the Direct Retrofit page.
What to check before changing modules
Fit. Module length, header spacing, permeate connection and the way the module locks into the cassette. Theway builds to the original dimensions; send the cassette drawing or the module model number and the fit is confirmed before an order.
Area per module. If the replacement has a different area, the flux changes at the same flow. Compass recalculates the design with the new module.
Scour air. The air per module in the operation manual may differ from the original; the blower usually has the range, but check it, because too little air shortens life and too much wastes power.
Permeate pump and vacuum. A new module runs at a lower suction. Keep the permeate pump on flow control, not on a fixed vacuum, or the new modules will be driven harder than designed.
Cleaning chemistry. Chlorine limits differ between makes. Set the maintenance and recovery clean doses to the Theway figures on the cleaning limits page on the day the modules go in.
Mixed liquor. Changing modules is a good moment to check MLSS, the screen and the sludge age, because the new membranes will be judged against the old ones under whatever conditions the plant is in.
A 1 MLD design in Compass
The drawing above is a 1 MLD municipal plant designed in Theway Compass with TW-MBR-40 modules: 2,810 m² of membrane needed at a peak factor of 1.5 and 20 L/m²·h; 80 modules installed in four cassettes of 20, two trains; scour air 880 Nm³/h from an 18 kW blower; permeate pumps of 35 m³/h each at peak. Whole-plant energy 0.79 kWh/m³ including process aeration. Compass holds the module data for every Theway submerged module, so the same design can be run with the module that fits your cassettes.
Every figure in this article comes from Theway Compass, Theway's free online design tool. Open it, enter your own flow, water and prices, and it gives the same tables for your plant.
Questions
Can one cassette be changed at a time? Yes. The common practice is to change a train at a time, which keeps the plant running and lets the new modules be compared with the old under the same sewage.
Do you supply cassettes as well? For the ZeeWeed 500D family, complete cassettes TW-CAS-48 and TW-CAS-16 are made; for other makes the original cassette is kept and only the modules change.
What about the warranty? Theway's written terms of sale apply; the operation manual sets the flux, chlorine and scour limits the warranty depends on.
Send your plant details to mail@thewaymembranes.com or use the enquiry form for a quotation and a reviewed design.
Specification note. Typical values only. They depend on feed water, system design and operation in line with the Theway operation manual, and may change without notice. Prices in this article are assumptions for illustration, not Theway's prices; ask Theway for a current quotation.
Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.