How to read a UF membrane datasheet

Nov 12
3 min read

Updated: 11 hours ago

At a glance: a UF datasheet gives the membrane (material, MWCO, fibre size, area), the module (housing, caps, potting, flow direction) and the operating limits (feed pressure, transmembrane pressure, backwash pressure, pH, temperature, flux ranges and cycle times). The limits are maximums, not set points, and the pressure limits fall as water temperature rises.

How to read a UF membrane datasheet

Field by field

The example values are from the TW 250/1650 Stream module.

Field

Example

What it means

Type

Hollow fibre

Fibre geometry; the other main type is flat sheet

MOC of membrane

PES or PVDF

Membrane polymer; sets chemical and oxidant tolerance

MOC of body

PVC

Housing material

Potting material

Proprietary epoxy

Resin that seals fibres into the end caps

MOC of cap

PVC or PP

End cap material

MWCO

100 kDa

Molecular weight cut-off; see kDa unit explained

Area

80 m²

Total active membrane area in the module

Size of fibre

1.2 mm OD × 0.6 mm ID

Fibre outer and inner diameter

Flow

Out-in

Feed outside the fibre, filtrate inside; see out-in vs in-out

Operating mode

Cross flow or dead end

Feed pressure

3 kg/cm² max

Highest pressure the housing and fibre may see

Transmembrane pressure

1 kg/cm² max

Highest pressure difference across the membrane

Backwash pressure

2 kg/cm² max

Highest pressure on the filtrate side during backwash

Operating pH

2 to 11

Range for continuous operation; cleaning pH is given separately (1 to 13 on Theway hollow fibre UF)

Operating temperature

20 to 45 °C

Range of feed temperature

Feed flux

20 to 100 L/m²·h

Range of filtration flux; the design value depends on the feed

Backwash flux

40 to 150 L/m²·h

Range of reverse flow rate during backwash

Filtration time

15 to 60 min

Time between backwashes

Backwash time

20 to 60 s

Length of each backwash

Flushing time

20 to 60 s

Length of each forward flush

Units

1 kg/cm² is 98.1 kPa, or 0.981 bar. 1 bar is 100 kPa, or about 14.5 psi. L/m²·h (often written LMH) is litres of filtrate per square metre of membrane per hour.

Temperature derating

Warm water softens polymers, so the allowed pressures fall as temperature rises. For the TW 250/1650:

Water temperature

Maximum system pressure

Maximum TMP

Maximum backflush pressure

0 to 20 °C

300 kPa

100 kPa

200 kPa

20 to 25 °C

275 kPa

95 kPa

175 kPa

25 to 30 °C

250 kPa

90 kPa

150 kPa

30 to 35 °C

225 kPa

85 kPa

125 kPa

35 to 40 °C

200 kPa

80 kPa

100 kPa

Plants with warm feed water, such as seawater intakes in the Gulf, should design to the hot-season limits.

How to use a datasheet

  • Design flux sits inside the feed flux range; where it sits depends on the feed water.

  • Set pump and valve limits below the maximum pressures, allowing for pressure surges.

  • Check cleaning chemicals against the pH range and the temperature limit.

  • Set cycle times within the stated ranges, then adjust from operating data.

Questions buyers ask

Is the 100 L/m²·h flux a design value?

No. It is the top of the range. Most plants design well inside it.

Why is feed pressure higher than TMP?

Feed pressure is measured against atmosphere; TMP is the difference between feed and filtrate sides.

Which limit applies if the water warms up during the day?

Design to the limit for the highest temperature the plant will see.

Ask for a datasheet

Datasheets for every Stream and retrofit model are on the Stream UF page and the direct retrofit page. For anything else, use Send Enquiry or mail@thewaymembranes.com.

Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.