kDa unit explained: what a kilodalton means for membranes
Updated: 3 hours ago
At a glance: kDa stands for kilodalton, a unit of molecular mass. One dalton (Da) is one twelfth of the mass of a carbon-12 atom, and 1 kDa is 1,000 Da, which is numerically the same as a molar mass of 1,000 g/mol. Ultrafiltration membranes are rated in kDa through their molecular weight cut-off (MWCO): the molecular mass of a test solute that the membrane retains to a stated degree, commonly 90%.

The dalton and the kilodalton
The dalton is the unified atomic mass unit. Chemists and biologists use it to state the mass of molecules:
a water molecule is about 18 Da
glucose is about 180 Da
the protein lysozyme is about 14 kDa
bovine serum albumin is about 66 kDa
an antibody (IgG) is about 150 kDa
Because 1 Da corresponds to 1 g/mol, a protein of 66 kDa has a molar mass of about 66,000 g/mol.
How membranes are rated in kDa
A UF membrane has a spread of pore sizes, not a single size. Makers therefore rate it by what it holds back. The MWCO test filters a solution of test molecules of known mass (dextrans, polyethylene glycols or proteins) and measures how much of each passes. The MWCO is the molecular mass at which retention reaches the stated value, commonly 90%.
MWCO | Typical use |
|---|---|
10 kDa | Concentrating proteins and enzymes |
20 to 50 kDa | Separating larger proteins; some food and dairy duties |
67 kDa | Separations around the size of serum albumin |
100 kDa | Water and wastewater treatment: suspended solids, colloids, bacteria |
150 kDa | Water treatment duties where higher permeability matters, such as Theway's Puran Max retrofits |
Theway makes fibre with MWCO options of 100, 67, 50, 20 and 10 kDa. The standard Stream UF modules are rated at 100 kDa.
Why kDa does not convert exactly to microns
Molecular mass is not the same as molecular size. Two molecules of the same mass can have different shapes: a compact globular protein passes a pore that a long, flexible chain of the same mass may not. Charge, the test solute and test conditions also change the result. Any table that converts kDa to microns is an approximation for one kind of molecule. Our posts on kDa to microns and microns to kDa explain this in detail.
For water treatment the practical point is simple: bacteria, protozoan cysts, colloids and suspended solids are far larger than the pores of a 100 kDa membrane, so the membrane removes them by size.
How to read an MWCO on a datasheet
Check which retention level the MWCO refers to, usually 90%.
Check the test solute if the separation is critical, for example in protein work.
For water treatment, compare MWCO together with fibre material and flux. A lower MWCO is not automatically better; it often means lower permeability.
Questions buyers ask
What does "kDa" stand for?
Kilodalton: one thousand daltons, a unit of molecular mass.
Is a 100 kDa membrane finer than a 150 kDa membrane?
Yes. A lower MWCO means the membrane retains smaller molecules.
Does a lower MWCO give better water for RO feed?
Not necessarily. Particles and bacteria that foul RO are far larger than the pores of either. Choose the MWCO that holds the flux you need on your water.
Can I get the pore size in microns?
Theway rates membranes by both pore diameter and MWCO. Ask us for the figures for the module you are considering.
Need a membrane for a specific separation?
Tell us what you need to retain and what must pass through Send Enquiry or mail@thewaymembranes.com.
Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.




Comments