top of page

Designing UF ahead of RO as one system

2 hours ago
4 min read

The short answer

Size the UF for the RO feed flow, not the RO permeate flow, and size it in the coldest water. Then judge the plant on two figures:

  • Overall recovery: raw water in to permeate out.

  • Energy per m³ of permeate: UF and RO together.

In the Compass examples below:

  • Seawater: 100 m³/h of permeate needs 259.7 m³/h of raw water. Overall recovery is 38.5 %, and the whole plant uses 2.33 kWh/m³, of which the UF is 0.057.

  • River water: the same 100 m³/h needs 141.1 m³/h of raw water. Overall recovery is 70.9 %, at 0.50 kWh/m³ in total.

UF ahead of the RO also allows a higher RO flux guideline. That can save 9 to 15 % of the RO elements.

Why design them together

Designed separately, the UF and RO each look right on their own, but the plant may not balance:

  • The UF must feed the RO. The RO feed is the permeate divided by the RO recovery: 250 m³/h for 100 m³/h of seawater permeate at 40 %. The UF also uses some of its own filtrate for backwashes and chemical cleans. So the raw water intake is larger again.

  • Recoveries multiply. Overall recovery is the RO recovery times the UF recovery: 40 % × 96.3 % = 38.5 %. The UF waste is a small stream, but it sets the intake and the outfall.

  • Temperature works differently on each. The UF flux falls in cold water because the water is more viscous, so the UF is sized in the coldest month. The RO pump is also sized in the coldest month, but its permeate quality is checked in the warmest.

  • Pretreatment changes the RO design. With UF filtrate (SDI below 3), the RO can run at a higher flux guideline than with conventional media filtration.

Theway Compass worked examples

Basis, both cases:

  • 100 m³/h of RO permeate, 24 hours a day, three years of RO membrane age.

  • Stream TW 250/1650 UF modules (80 m² each), dead-end filtration with backwash and chemically enhanced backwash (CEB).


Seawater

River water

Feed

35,228 mg/L, 25 °C, UF sized at 18 °C, 5 NTU

511 mg/L, 25 °C, UF sized at 15 °C, 20 NTU

RO

24 × 7 Osmoflux MR TW 400, 40 % recovery, pressure exchanger

12 × 6 + 6 × 6 Osmoflux LE TW 400, 75 % recovery

UF modules

54, in 3 racks of 18

34, in 2 racks of 17

UF flux while filtering

64.8 L/m²·h

56.3 L/m²·h

UF recovery

96.3 %

94.5 %

Raw water to the UF

259.7 m³/h

141.1 m³/h

UF backwash and cleaning waste

9.7 m³/h

7.7 m³/h

UF filtrate to the RO feed

250.0 m³/h

133.3 m³/h

RO concentrate

150.0 m³/h

33.3 m³/h

Overall recovery

38.5 %

70.9 %

RO feed pressure

51.5 bar

8.5 bar

RO permeate TDS

216 mg/L

6 mg/L

Power: UF and RO

5.7 and 227.1 kW

3.1 and 47.2 kW

Energy per m³ of permeate: UF, RO, total

0.057, 2.27, 2.33 kWh/m³

0.031, 0.47, 0.50 kWh/m³

What the examples show:

  • The UF is a small share of the energy. It is 2 % of the total on seawater and 6 % on river water. Its real cost is in intake, pumping and chemicals, and its real value is a steady RO feed.

  • Size the UF on the RO feed flow. Sizing the river-water UF for 100 m³/h instead of 133.3 m³/h would leave it a quarter short.

  • The UF waste matters most on low-salinity water. On river water, UF waste is 7.7 m³/h against an RO concentrate of 33.3 m³/h. It takes about 4 points off the overall recovery.

UF pretreatment and the RO flux guideline

Compass uses a higher RO flux guideline when the feed comes from UF. These are the guideline target fluxes, and the number of 37 m² elements they imply for 100 m³/h of permeate:

Water

Conventional pretreatment

UF pretreatment

Elements saved

Seawater, open intake

14.0 L/m²·h, 194 elements

16.5 L/m²·h, 164 elements

about 15 %

Surface water

23.5 L/m²·h, 116 elements

25.5 L/m²·h, 106 elements

about 9 %

The steadier feed also means fewer RO cleans. For seawater, see UF for seawater RO pre-treatment: sizing a rack.

How to do it in Theway Compass

  1. Design the RO first: water analysis, flows and array.

  2. On the RO results, choose Size the UF for this RO. Compass sets the UF feed type from the RO water type, and copies the coldest and warmest temperatures.

  3. Check the turbidity and the module. The UF filtrate now follows the RO feed flow, including any second-pass recycle.

  4. The UF results show the integrated system: raw water, each waste stream, overall recovery and energy per m³ of permeate.

  5. The RO results and PDF then cover the whole plant, with the UF modules in the supply list.

For wastewater reuse, the same step sizes an MBR ahead of the RO.

Try it in Theway Compass.

Questions engineers ask

Should the UF be sized for the RO permeate or the RO feed?

The RO feed. The UF must deliver everything the RO takes in. Its own backwash and cleaning water comes on top, from the raw water side.

At what temperature should the UF be sized?

The coldest. Viscosity rises in cold water and the sustainable flux falls. In the seawater example the UF is sized at 18 °C, although the RO design point is 25 °C.

How much does the UF add to the energy?

In these examples, 0.03 to 0.06 kWh/m³ of permeate: 2 to 6 % of the plant total.

Does UF pretreatment let the RO run at a higher flux?

Yes. Compass uses a higher flux guideline for UF-pretreated water: 16.5 against 14.0 L/m²·h for open-intake seawater, and 25.5 against 23.5 for surface water.

Can Theway supply the UF and the RO elements together?

Yes. Stream UF modules and Osmoflux RO elements are supplied together, with the pressure vessels. See the UF membranes and RO membranes ranges.

Specification note: The figures above are estimates from Theway Compass for the stated feed waters and design basis. They are for information only and are not a performance guarantee. Actual performance depends on the feed water, pre-treatment, operation and cleaning. Module and element figures are from Theway datasheets. See the product and datasheet disclaimer. Ask us for a quotation for your project.