Replacing Kubota flat sheet and Mitsubishi 5600 MBR elements: Theway
Updated: 8 hours ago
At a glance: Theway makes replacement elements for Kubota and Mitsubishi MBR systems: TW-0.8-FS and TW-1.5-FS flat sheet cartridges for Kubota flat sheet MBR cases, and the TW-MBR56-40 hollow fibre element for Mitsubishi STERAPORE 5600 units. Each is built to the size and connections of the element it replaces, so the tank, frames, diffusers and permeate piping stay as they are.

Element cross-reference
Element in service | Theway replacement | Membrane | Size |
|---|---|---|---|
Kubota flat sheet cartridge, Type 510 (0.8 m²) | TW-0.8-FS | PVDF flat sheet, 0.2 µm average pore, 0.8 m² | 1,000 × 490 × 6 mm, one top nozzle |
Kubota flat sheet cartridge, Type 515 (1.45 m²) | TW-1.5-FS | PVDF flat sheet, 0.2 µm average pore, 1.5 m² | 1,500 × 500 mm, two top nozzles |
Mitsubishi STERAPORE 5600 element (56E0040SA) | TW-MBR56-40 | PVDF hollow fibre, 0.05 µm, 40 m², fibre OD 1.65 mm | 2,000 × 1,250 × 30 mm, two Ø24 mm permeate outlets in the top header |
Brand and model names belong to their owners and are used here only to identify the elements each Theway element replaces.
Operating data
Parameter | TW-0.8-FS and TW-1.5-FS | TW-MBR56-40 |
|---|---|---|
Flow per element | Set by the plant design | 5 to 20 m³/day |
Flux | Set by the plant design | Up to 33 L/m²·h |
MLSS | Up to 18,000 mg/L | 5,000 to 10,000 mg/L recommended (3,000 to 15,000 limits) |
Transmembrane pressure | Up to 20 kPa | Initial TMP −15 kPa or above |
Temperature | 5 to 40 °C | On request |
pH | 5 to 10 | On request |
Gasket | Nitrile | Not applicable |
Flat sheet cartridges are cleaned in place with sodium hypochlorite for organic fouling and oxalic acid for inorganic scale. The datasheets for all three elements are linked from the Kubota and Mitsubishi rows of the direct retrofit table.
Questions buyers ask
Do I need new cases or frames?
No. The cartridges and the element are made to the size and connections of the ones they replace and go into the existing cases and frames.
Can I change part of a tank?
Elements in one case or unit share the suction, so change a whole case or unit at a time to keep the flow even.
Does Theway make complete MBR systems as well?
Yes: see the flat sheet MBR cassettes, the hollow fibre MBR modules and Surge 500T for ZeeWeed 500D tanks.
Retrofit guides by maker
Get a quotation
Send the element model, the number of cases or units, and recent flow, TMP and MLSS data through Send Enquiry or to mail@thewaymembranes.com. See also flat sheet or hollow fibre MBR.
Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.