top of page

Seawater RO energy: what a pressure exchanger saves with Osmoflux MR elements

3 days ago
2 min read

Updated: 5 hours ago

At a glance: in a seawater RO plant more than half the feed leaves as concentrate at over 50 bar. Without energy recovery that pressure is thrown away. On a 100 m³/h plant with Osmoflux MR TW 400 elements, Theway Compass projects about 4.9 kWh/m³ with no recovery, 2.9 with a turbocharger and 2.4 with a pressure exchanger.

The design

Seawater at 35,200 mg/L and 28 °C after UF pretreatment; 100 m³/h of permeate at 42 % recovery; 18 vessels of 7 Osmoflux MR TW 400 elements. Feed pressure is about 55 bar, permeate about 160 mg/L TDS and boron about 0.9 mg/L in a single pass.


No recovery

Turbocharger

Pressure exchanger

Pumps, kW

485

287

242

Specific energy, kWh/m³

4.85

2.87

2.42

Saved, kW

–

198

245

Pump efficiency 80 % with 95 % motors; turbocharger transfer efficiency 75 %; pressure exchanger efficiency 96 % with 1 % lubrication flow and 3 % mixing; feed pump through the cartridge filters included. At ₹8 per kWh, the pressure exchanger's 245 kW is worth about ₹1.7 crore a year in continuous operation.

How the two devices differ

  • Pressure exchanger. Transfers the concentrate pressure straight to an equal flow of feed with about 96 % efficiency. The high-pressure pump then handles only the permeate flow, and a small booster tops up the exchanger stream. About 3 % of the brine mixes into the feed, raising the membrane feed salinity slightly: permeate rises from about 158 to 161 mg/L.

  • Turbocharger. A turbine driven by the concentrate boosts the feed after the high-pressure pump. Simpler and cheaper, with lower efficiency. A good fit for smaller plants and for high-pressure brackish or brine duties.

Recovery and energy

With a pressure exchanger, raising recovery from 42 to 45 % barely changes specific energy (2.42 to 2.44 kWh/m³) but raises feed pressure from about 55 to 57 bar and the concentrate salinity. Higher recovery saves on intake and pretreatment; lower recovery eases scaling and boron.

Choosing elements

Osmoflux MR elements come in 400 and 440 ft² versions, including Osmoflux MR TW 440. Where a tight boron limit applies, Compass can model a partial second pass at raised pH. See the full Osmoflux range and UF for seawater RO pretreatment.

Questions

Does energy recovery change the membranes I need? No. The array is the same; only the pumps and the feed pressure seen by the elements change slightly.

Can I compare devices on my own plant? Yes. Every seawater projection in Theway Compass shows the same design with no device, a turbocharger and a pressure exchanger, with the saving in kW, MWh and, if you enter a price, money.

Figures are Theway Compass projections for the water and design shown, for information only. The device maker's own figures decide the final pumps.

Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.

Comments


bottom of page