Choosing a Stream UF model: TW 90 to TW 315
Updated: 7 hours ago
At a glance: Stream is Theway's own hollow fibre UF range, made in Chennai. Ten models cover 8 to 145 m² of membrane per module, in 1100 mm and 1650 mm lengths. Use the smaller models for pilots and small plants, the TW 200 and TW 250 sizes for mid-size plants, and the TW 315 sizes for large plants where fewer modules mean fewer connections.

The range
Model | Length (mm) | Area (m²) | Filtrate at 40 L/m²·h (m³/h) | Filtrate at 60 L/m²·h (m³/h) |
|---|---|---|---|---|
1100 | 8 | 0.32 | 0.48 | |
1100 | 20 | 0.8 | 1.2 | |
1100 | 40 | 1.6 | 2.4 | |
1100 | 55 | 2.2 | 3.3 | |
1100 | 95 | 3.8 | 5.7 | |
1650 | 12 | 0.48 | 0.72 | |
1650 | 35 | 1.4 | 2.1 | |
1650 | 60 | 2.4 | 3.6 | |
1650 | 80 | 3.2 | 4.8 | |
1650 | 145 | 5.8 | 8.7 |
Filtrate figures are gross output (area × flux) and are for comparison only. The design flux for your plant depends on your feed water.
All Stream modules share the same membrane: 1.2 mm OD × 0.6 mm ID hollow fibre in PES or PVDF, out-in flow, 100 kDa MWCO as standard, PVC housing, and operation in cross-flow or dead-end mode.
How to choose
1. Start from the total area. Divide the gross flow (net flow plus backwash and flush losses) by the design flux. See UF flux explained for a worked example.
2. Pick a length. The 1650 mm modules give more area per module and per connection. Choose 1100 mm where headroom is limited, where modules must be handled by one person, or for compact skids.
3. Pick a diameter. Fewer, larger modules mean fewer couplings, valves and integrity checks. Smaller modules give finer steps in capacity and smaller spare stock.
4. Check the train size. Aim for trains that can be backwashed and cleaned one at a time while the others keep running.
5. Keep spares common. Using one model across a site keeps spares simple.
Typical choices
Plant | Typical model |
|---|---|
Pilot or laboratory test | TW 90/1100 or TW 90/1650 |
Small STP polishing or a residential building | TW 160 or TW 200 sizes |
Industrial RO pre-treatment, 10 to 50 m³/h | TW 200/1650 or TW 250/1650 |
Large river water or seawater pre-treatment | TW 315/1650 |
Operating limits
Feed pressure up to 3 kg/cm², transmembrane pressure up to 1 kg/cm², backwash pressure up to 2 kg/cm², pH 2 to 11 and 20 to 45 °C, with feed flux of 20 to 100 L/m²·h and backwash flux of 40 to 150 L/m²·h. Pressure limits fall as temperature rises; the derating table is on each model page.
Questions buyers ask
1100 or 1650 mm?
1650 mm unless headroom, handling or skid size rules it out. It gives more area per connection.
PES or PVDF?
PES for cleaner surface and well water; PVDF where the feed is harder to treat and oxidant cleaning is frequent. We advise per project.
Can Stream modules replace another brand?
Stream modules suit new plants. To replace another brand without changing pipework, use a direct retrofit.
What if my flow falls between two sizes?
Choose the model that gives whole trains with a standby, then adjust the design flux within its range.
Size your plant
Send flow and feed water data through Send Enquiry or to mail@thewaymembranes.com. The full range is on the Stream UF page.
Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.