UF membrane flux explained: design flux, recovery and sizing
Updated: 11 hours ago
At a glance: flux is the filtrate flow per square metre of membrane, in L/m²·h (LMH). A datasheet gives a range, such as 20 to 100 LMH for Theway Stream modules. The design flux for your plant sits inside that range: towards the top on clean, cool well water and towards the bottom on effluents and difficult surface water. A lower design flux means more membrane but fewer cleans and longer life.

Flux, gross and net
Gross flux: total filtrate produced divided by membrane area.
Net flux: filtrate delivered after backwash water is taken out.
Recovery: net filtrate divided by feed water used.
Choosing a design flux
Feed water | Where design flux usually sits |
|---|---|
Clean groundwater, low turbidity | Upper part of the range |
Surface water after screening | Middle of the range |
Surface water with monsoon turbidity spikes | Lower-middle; design for the worst season |
Seawater | Lower-middle; allow for algal blooms and warm water |
Secondary-treated sewage or industrial effluent | Lower part of the range |
A pilot is the surest way to set flux on unusual water. See the merits of piloting.
Worked example
A plant needs 50 m³/h of net filtrate.
1. Allow for backwash losses. Assume 92% recovery for now. Gross filtrate = 50 ÷ 0.92 = 54.3 m³/h.
2. Choose a design flux. Surface water after screening: 60 LMH.
3. Area needed. 54,300 L/h ÷ 60 LMH = 905 m².
4. Choose modules. TW 250/1650 has 80 m²: 905 ÷ 80 = 11.3, so 12 modules (960 m²). The actual flux is 54,300 ÷ 960 = 57 LMH. Alternatively, seven TW 315/1650 modules at 145 m² give 1,015 m² and 53 LMH.
5. Check recovery. With 12 × TW 250/1650:
filtration 30 min: 54.3 × 0.5 = 27.2 m³ of filtrate per cycle
backwash 40 s at 150 LMH: 960 m² × 150 LMH = 144 m³/h, × 40/3,600 h = 1.6 m³
forward flush 30 s at feed flow: about 0.45 m³ of feed
recovery = (27.2 − 1.6) ÷ (27.2 + 0.45) = 93%
That is close to the 92% assumed, so the sizing holds. CEB and CIP water lower recovery a little further.
6. Add a standby. Plants that must run while one train is cleaned need extra area or an extra train.
Checklist
Design flux chosen from feed water, not the top of the datasheet range
Gross flow includes backwash and flush losses
Module count rounded up, actual flux recalculated
Recovery checked with real cycle settings
Standby capacity for cleaning
Cold-season flow checked
Questions buyers ask
Can I run at 100 LMH?
On very clean water for short periods, perhaps. Most plants foul quickly at the top of the range and need more cleaning.
Why does output drop in winter?
Water is more viscous when cold, so flux falls at the same TMP. See TMP explained.
What flux do MBR membranes run at?
Much lower. Submerged modules run under suction at low TMP, so their flux sits well below the pressurised range; for TW-MBR modules the design figure depends on site conditions.
Where can I read more about sizing?
See our UF sizing guide and choosing a Stream model.
Get your plant sized
Send flow and feed water data through Send Enquiry or to mail@thewaymembranes.com.
Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.