CIP for hollow fibre UF: a step-by-step guide
Updated: 11 hours ago
At a glance: clean in place (CIP) when normalised permeability has fallen to your trigger level or TMP approaches the datasheet limit. Use an alkaline clean with an oxidant for organic and biological fouling, and an acid clean for scale and metals. Circulate on the feed side, soak, rinse, and compare permeability at the same temperature before and after.

When to clean
UF plants clean at three levels: routine backwash, chemically enhanced backwash (CEB) and CIP. See backwash, CEB and CIP. Run a CIP when:
temperature-corrected permeability has fallen by your set fraction from the clean baseline
TMP is approaching the datasheet maximum (1 kg/cm² for Theway Stream and retrofit modules)
backwash and CEB no longer bring TMP back down
Match the chemistry to the foulant
Foulant | Typical sign | Cleaning chemistry |
|---|---|---|
Organic matter, biofilm | Slow, steady TMP rise; slimy deposits | Alkaline clean with sodium hydroxide and sodium hypochlorite |
Scale (calcium, magnesium) | Rise after pH or temperature change; hard white deposits | Acid clean with citric or hydrochloric acid |
Iron and manganese | Brown or black deposits | Acid clean; citric or oxalic acid work well on iron |
Oil and grease | Fast TMP rise after an upset | Alkaline clean, after the oil source is fixed |
Colloidal silica, clay | Rise with turbidity spikes | Alkaline clean; review pre-treatment |
If you do not know the foulant, run the alkaline clean first, then the acid clean.
Step by step
Backwash the train and drain it.
Prepare the cleaning solution in the CIP tank with UF filtrate or RO permeate. Warm it if your system allows, staying at or below 40 °C, the cleaning temperature limit of Theway hollow fibre UF modules.
Check pH stays within the cleaning limit: pH 1 to 13 for Theway Stream and retrofit hollow fibre modules (operating pH 2 to 11). Each module's datasheet gives its limits.
Circulate on the feed side at low pressure for the set time.
Soak with the pump off. Fouled modules benefit from a longer soak.
Circulate again, then drain the solution to neutralisation.
Rinse with clean water until pH returns to that of the rinse water.
Repeat with the second chemical if needed.
Backwash and return to service at reduced flux, ramping up.
Record flow, TMP and temperature to calculate the new permeability.
Did it work?
Compare permeability (flux divided by TMP, corrected to the same temperature) before and after. A good clean returns most of the clean baseline. If permeability barely moves, the chemistry did not match the foulant, or the fouling is irreversible. Send us the data.
Checklist
Trigger levels set from the baseline
Foulant identified, or both cleans planned
Solution pH and temperature within datasheet limits
Circulate, soak, circulate, rinse
Neutralise before discharge
Before and after permeability recorded
Questions buyers ask
How often should I clean?
As often as the data says. A stable plant on clean water may go weeks between CIPs; difficult effluents need more. If CIP frequency is rising, look at pre-treatment and flux.
Can I use sodium hypochlorite on PES and PVDF?
Both tolerate hypochlorite cleaning within limits that differ by polymer: up to 200 ppm at pH 10 or above for PES, up to 2,000 ppm for PVDF and up to 5,000 ppm for TIPS PVDF (Puran Max). Each datasheet gives the limit for its module.
Is hot cleaning better?
Warmer solutions clean faster, but never exceed the module temperature limit.
Should cleaning water come from the UF itself?
UF filtrate or RO permeate, yes. Never mix up cleaning solutions with raw feed water.
Need a cleaning recipe?
Send your foulant signs and operating data through Send Enquiry or to mail@thewaymembranes.com. See also UF fouling: types and causes.
Further reading: When to clean RO and UF: reading normalised data.
Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.