Nitrate in borewell water: RO or nanofiltration?
Updated: 3 hours ago
At a glance: IS 10500 allows no more than 45 mg/L of nitrate (as NO₃) in drinking water, with no relaxation. RO removes nitrate reliably, to a few mg/L. Tight nanofiltration removes roughly half of it, which may or may not be enough. Loose nanofiltration softens the water but leaves nearly all the nitrate. Check the projected permeate nitrate before choosing NF for a nitrate problem.
Why NF holds back hardness but not nitrate
Nanofiltration membranes reject divalent ions such as calcium, magnesium and sulfate strongly, and monovalent ions much less. Nitrate is monovalent and small, so it passes NF more easily than chloride. RO rejects all ions, so nitrate falls with the rest of the salt.
Projection: a nitrate-rich borewell
Borewell water with 973 mg/L TDS, 80 mg/L nitrate and 369 mg/L hardness as CaCO₃, at 28 °C. Each plant makes 100 m³/h at 75 % recovery in a 11 × 6 plus 5 × 6 array. Projected with Theway Compass:
RO: Osmoflux BR TW 400 | Tight NF | Loose NF | |
Permeate nitrate, mg/L | About 2 | About 36 | About 75 |
Permeate TDS, mg/L | About 8 | About 110 | About 640 |
Permeate hardness, mg/L as CaCO₃ | Below 1 | About 7 | About 190 |
Feed pressure, bar | 8.8 | 4.3 | 3.1 |
Specific energy, kWh/m³ | 0.49 | 0.26 | 0.21 |
Tight NF meets 45 mg/L here, but with little margin: nitrate passage rises as membranes age, in warmer water and when the raw water nitrate climbs after the monsoon. Loose NF does not meet the limit at all.
Choosing the route
RO with blending. RO permeate at about 2 mg/L nitrate can be blended with filtered raw water to restore minerals. With 80 mg/L in the raw water, keep the bypass under about 45 % so the blend stays below 40 mg/L. Remineralise or blend to bring the pH and hardness back.
Tight NF. Worth considering when nitrate is moderate (below about 60 mg/L), energy matters and some minerals should stay in the water. Design for the worst season and the oldest membranes.
Loose NF. For softening, colour and organics, not for nitrate.
Low-pressure RO elements such as Osmoflux LE TW 400 cut energy further on low-TDS water. For softening duties see the Theway NF 8040 element and NF for softening.
Questions
Does fluoride behave like nitrate? Partly. Fluoride is monovalent but more strongly rejected; in this projection tight NF left about 0.2 mg/L, well within IS 10500.
Can I check my own water? Yes. Enter your analysis in Theway Compass and switch between the RO and NF tabs; the permeate table shows nitrate ion by ion.
Figures are Theway Compass projections for the water and design shown, for information only. Confirm with a pilot test before relying on NF for nitrate.
Further reading: Silica in brackish RO: the recovery limit explained.
Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.