What a UF plant costs to run per m³: electricity, chemicals and membranes
Updated: 1 day ago
At a glance: for a 2.4 MLD (100 m³/h) hollow fibre UF plant on river water, the UF skid itself uses about 0.02 kWh/m³, chemicals for chemically enhanced backwashes and monthly cleans come to about ₹0.15/m³, and the membranes add roughly ₹0.4 to ₹0.6 per m³ for every lakh of rupees a module costs, depending on how many years it lasts. Raw water pumping, labour and maintenance sit on top. The numbers below are a worked example; put your own flow, water and prices into Theway Compass to get the same tables for your plant.
The plant in the example
Item | Value |
|---|---|
Net filtrate | 100 m³/h, 24 hours a day (2.4 MLD) |
Feed water | River water, 20 NTU, 25 °C |
Module |
|
Design flux | 61 L/m²·h at 20 °C from the Compass surface water guideline |
Modules | 24 in two racks of 12 |
Cycle | 45 minute filtration, backwash at 100 L/m²·h, forward flush, CEB every 15 cycles (hypochlorite with caustic twice, acid once) |
Clean in place | Every 30 days, caustic with hypochlorite then citric acid |
Recovery | 94.8 % |
Availability | 90.7 % after backwashes, CEBs, cleans and a daily integrity test |
The drawing above is the Compass plant view of this design: feed pumps, two racks, the backwash pump drawing from the filtrate tank, and the dosing points for hypochlorite, caustic and acid.
Electricity
Compass works out the energy from the pressure each pump actually sees and the hours it runs. Across the membrane the pressure between cleans is about 0.3 bar, so the feed pumps run at about 0.4 bar while filtering. The backwash pump, the air scour blower, cleaning and the controls add a little more.
Consumer | kW | kWh a day |
|---|---|---|
Feed pumps, 0.42 bar while filtering | 1.6 | 39 |
Backwash and CEB pump, 0.8 bar | 0.13 | 3.2 |
Air scour blower, 0.5 bar | 0.06 | 1.4 |
Cleaning pump and solution heating | 0.07 | 1.8 |
Controls and instruments | 0.1 | 2.4 |
UF skid total | about 2.0 | 48, which is 0.020 kWh/m³ |
At ₹8 per kWh that is ₹0.16 per m³ of filtrate. Two things change it most:
Raw water lift. Compass draws the boundary at the UF skid. If the raw water pump has to deliver the 105 m³/h gross flow at 1.5 bar from a sump, add about 6.8 kW at 65 % efficiency, or 0.07 kWh/m³, which is three times the skid itself.
Fouling. The 0.3 bar across the membrane assumes the CEB and cleaning programme keeps the membrane near its clean pressure. A plant run to 1 bar before cleaning uses two to three times the feed pump energy.
Chemicals
Chemical use follows the CEB programme, not the flow. In this example one CEB in every three is acid and two are hypochlorite with caustic; the monthly clean uses caustic with hypochlorite, then citric acid.
Chemical, as 100 % | kg a year | Price assumed | ₹ per m³ |
|---|---|---|---|
Sodium hypochlorite for CEB, 200 mg/L | 257 | ₹150/kg | 0.044 |
Caustic soda for CEB, 400 mg/L | 514 | ₹45/kg | 0.026 |
Hydrochloric acid for CEB, pH 2 | 234 | ₹30/kg | 0.008 |
Citric acid for cleaning, 2 % | 520 | ₹120/kg | 0.071 |
Caustic and hypochlorite for cleaning | 39 | as above | 0.004 |
Total | about 0.15 |
Prices are for the active chemical: commercial 12 % hypochlorite at ₹18 a kilogram is ₹150 per kilogram of NaOCl. The citric acid clean is the largest line. Plants that can use a hydrochloric acid clean instead, where the fouling is mineral rather than iron or manganese, cut the chemical cost by about a third.
Membranes
The membrane term is the one that varies most between suppliers, and it is simple to work out: the number of modules, times the price of a module, divided by the years they last and the water they make in a year.
This plant makes 876,000 m³ a year with 24 modules. For every ₹1 lakh a module costs:
Membrane life | Membrane cost per m³, per ₹1 lakh a module |
|---|---|
5 years | ₹0.55 |
7 years | ₹0.39 |
10 years | ₹0.27 |
So a module that costs twice as much has to last twice as long to cost the same per m³. Life depends on the feed water, on keeping the plant within its flux, pressure and chlorine limits, and on cleaning before fouling sets hard; Theway's cleaning limits page lists the figures for each series. Theway quotes module prices on request; what drives the cost of a UF module explains what you are paying for.
Putting it together
Line | ₹ per m³ in the example |
|---|---|
Electricity, UF skid | 0.16 |
Electricity, raw water pump at 1.5 bar | 0.54 |
Chemicals | 0.15 |
Membranes, ₹1 lakh a module, 7 years | 0.39 |
Total before labour, maintenance and waste disposal | about 1.25 |
Waste is 134 m³ a day, 5.2 % of the feed, from backwashes, flushes and CEBs; where it is charged for, Compass adds it as a line when you enter a disposal price. Labour and routine maintenance are site matters and are left out.
What moves the number
Design flux: a higher flux needs fewer modules but shortens their life and raises the pressure; the Compass guideline for each source water is a good starting point.
Water quality: turbidity above the guideline, iron, manganese and organics all add CEBs and cleans.
Automation: a plant that backwashes on pressure rise rather than on a fixed timer uses less water and energy when the water is clean.
Module price and life: the largest line in most plants, and the one a direct comparison of quotations most often gets wrong by ignoring life.
Every figure in this article comes from Theway Compass, Theway's free online design tool. Open it, enter your own flow, water and prices, and it gives the same tables for your plant.
Questions
Does the energy figure include the RO downstream? No. This is the UF plant alone. For UF ahead of RO see UF as RO pretreatment.
Why is the skid energy so low? Hollow fibre UF runs at a fraction of a bar across the membrane. Most of the electricity in a real plant goes into lifting the water to the skid and into any pre-treatment, which is why the raw water pump line is shown separately.
Can I use this for an MBR? No; an MBR carries the aeration of the biological process, which dominates its energy. See MBR membrane replacement cost.