Transmembrane pressure (TMP) explained
Updated: 11 hours ago
At a glance: transmembrane pressure (TMP) is the pressure difference between the feed side and the filtrate side of a membrane. In dead-end operation it is feed pressure minus filtrate pressure; in cross-flow it is the average of feed and concentrate pressure minus filtrate pressure. Divide flux by TMP to get permeability, correct it for temperature, and you have the single best measure of how fouled a UF membrane is.

Calculating TMP
Dead end: TMP = P(feed) − P(filtrate)
Cross flow: TMP = [P(feed) + P(concentrate)] ÷ 2 − P(filtrate)
Example, cross flow: feed 1.2 bar, concentrate 1.0 bar, filtrate 0.4 bar. TMP = (1.2 + 1.0) ÷ 2 − 0.4 = 0.7 bar.
Units
Unit | Equivalent |
|---|---|
1 bar | 100 kPa, about 14.5 psi |
1 kg/cm² | 98.1 kPa, 0.981 bar |
1 kPa | 10 mbar |
Theway Stream and retrofit datasheets give a maximum TMP of 1 kg/cm², about 98 kPa, reducing at higher temperatures. Submerged MBR modules run under suction at much lower TMP: Theway's flat sheet MBR is limited to 20 kPa (200 mbar), and Surge 500T runs between −55 and 55 kPa.
From TMP to permeability
TMP on its own rises and falls with flow. Permeability removes that effect:
Permeability = flux ÷ TMP, in L/m²·h·bar
Example: 56 L/m²·h at 0.7 bar gives a permeability of 80 L/m²·h·bar.
Correcting for temperature
Water viscosity changes with temperature, so a clean membrane passes less water when cold. Correct permeability to a reference temperature, usually 20 °C:
Permeability at 20 °C = measured permeability × (viscosity at T ÷ viscosity at 20 °C)
Water temperature | Viscosity (mPa·s) | Factor to 20 °C |
|---|---|---|
15 °C | 1.138 | 1.14 |
20 °C | 1.002 | 1.00 |
25 °C | 0.890 | 0.89 |
30 °C | 0.797 | 0.80 |
35 °C | 0.719 | 0.72 |
Without this correction, a plant can look fouled every winter and clean every summer.
What TMP tells you
Steady rise between backwashes, full recovery after: normal cake build-up.
Recovery after backwash getting worse: fouling the backwash cannot remove; time for a CEB or CIP.
Sudden jump: feed upset, coagulant overdose, oil or a valve fault.
Sudden drop: possible integrity breach or bypass. Run an integrity test.
Checklist
Read feed, concentrate and filtrate pressures at the same time
Calculate TMP the right way for your operating mode
Convert to permeability
Correct to 20 °C
Trend daily against the clean baseline
Keep TMP below the datasheet limit for the water temperature
Questions buyers ask
What TMP should a new UF plant run at?
Well below the maximum. A clean, well-designed plant has plenty of margin, so fouling can build before cleaning is needed.
Why do pressure limits fall when the water is warm?
Polymers soften as temperature rises. The datasheet guide shows the derating table for a Stream module.
Is high TMP always fouling?
No. Check temperature, flow and instruments first.
Need help reading your data?
Send your log through Send Enquiry or to mail@thewaymembranes.com. Module limits are on the Stream UF page.
Further reading: When to clean RO and UF: reading normalised data.