top of page

Replacing FilmTec, Hydranautics, Toray and LG Chem 8040 RO elements: Osmoflux

Nov 15
3 min read

Updated: 8 hours ago

At a glance: Theway's Osmoflux 8040 elements replace spiral-wound RO elements from DuPont FilmTec, Hydranautics, Toray and LG Chem in the same 8-inch pressure vessels. Each element in service maps to an Osmoflux type: BR for brackish water, BFR for fouling-prone feeds, LE for low pressure, HSR for high salt rejection and MR for seawater. All use a polyamide thin-film composite membrane made by Theway from its own flat sheet.

Osmoflux 8040 RO element

Element cross-reference

Element in service

Osmoflux replacement

Active area

Permeate flow

Stabilised salt rejection

DuPont FilmTec BW30-365

34 m² (365 ft²)

9,500 gpd (36.0 m³/d)

99.5%

DuPont FilmTec BW30-400

37 m² (400 ft²)

11,500 gpd (43.5 m³/d)

99.8%

DuPont FilmTec Fortilife CR200

37 m² (400 ft²)

12,500 gpd (47.3 m³/d)

99.7%

DuPont FilmTec SW30-8040

28 m² (300 ft²)

6,000 gpd (22.7 m³/d)

99.1%

Hydranautics ESPA2

37 m² (400 ft²)

9,000 gpd (34.1 m³/d)

99.6%

Hydranautics CPA2

34 m² (365 ft²)

10,000 gpd (37.9 m³/d)

99.7%

Hydranautics CPA3

37 m² (400 ft²)

11,000 gpd (41.6 m³/d)

99.7%

Toray TM820V-400

37 m² (400 ft²)

9,000 gpd (34.1 m³/d)

99.8%

Toray TM820V-440

41 m² (440 ft²)

9,900 gpd (37.5 m³/d)

99.8%

LG Chem SW 440 R

41 m² (440 ft²)

9,900 gpd (37.5 m³/d)

99.8%

Brand and model names belong to their owners and are used here only to identify the elements each Osmoflux element replaces.

Test conditions behind the figures

Flow and rejection are measured under standard test conditions, which differ between element types. Compare elements only at the same conditions.

Osmoflux type

Test conditions

BR, BFR

2,000 ppm NaCl, 225 psi (1.55 MPa), 25 °C, pH 8, 15% recovery

HSR

1,500 ppm NaCl, 225 psi (1.55 MPa), 25 °C, pH 6.5 to 7, 15% recovery

LE

1,500 ppm NaCl, 150 psi (1.05 MPa), 25 °C, pH 6.5 to 7, 15% recovery

MR TW 400 and 440

32,000 ppm NaCl, 800 psi (5.5 MPa), 25 °C, pH 8, 8% recovery

MR TW 300

32,000 ppm NaCl, 800 psi (5.5 MPa), 25 °C, pH 8, 10% recovery

Choosing the type

  • BR: high flow and high rejection for brackish well, surface and UF-treated water.

  • BFR: for feeds with organic and biological load, such as treated effluent and surface water.

  • LE: rated at 150 psi, for low-pressure operation on low-TDS feeds.

  • HSR: extra-high rejection for low-TDS permeate on brackish feeds.

  • MR: for seawater desalination and other high-TDS feeds.

All types are described on the RO membranes page. For element sizes and pressure classes, see the RO membrane selection guide.

Questions buyers ask

Which Osmoflux element replaces the FilmTec BW30-400?

Osmoflux BR TW 400: 37 m² of active area, 11,500 gpd and 99.8% stabilised rejection at its test conditions.

Which replaces the Hydranautics ESPA2?

Osmoflux LE TW 400, a low-energy element rated at 150 psi.

Which replaces the Toray TM820V-400 seawater element?

Osmoflux MR TW 400: 37 m², 9,000 gpd and 99.8% stabilised rejection at 32,000 ppm NaCl and 800 psi.

Can I replace only some elements in a vessel?

Elements in one vessel share the same flow, so a whole vessel, or better a whole stage, should be changed at a time. Send us the projection or the operating data and we will check the design.

Retrofit guides by maker

Get a quotation

Send the element model, the number of vessels and elements, the feed water analysis and recent operating data through Send Enquiry or to mail@thewaymembranes.com. The RO rows in the direct retrofit table list every pair.

Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.

Comments


bottom of page