Replacing Koch TARGA, Suez ZeeWeed 1500 and Hyflux UF modules
Updated: 11 hours ago
At a glance: Theway makes direct retrofits for three more pressurised UF modules. Torrens 100 replaces the Koch TARGA II 10072-35 and Vatten 55 replaces the Suez ZeeWeed 1500, both at equivalence level 8. Supraflux 55 replaces the Hyflux K600ETI-55 at level 7. For submerged ZeeWeed 500D MBR cassettes, the matching module is Surge 500T.

A Hyflux replacement in service

A refinery in Eastern India replaced its Hyflux Kristal UF modules with Theway Supraflux in 2025. It treats about 8 MLD of river water ahead of RO with filtrate turbidity below 0.1 NTU and SDI below 2. Photos and details.
Model cross-reference
Existing module | Theway retrofit | Level |
|---|---|---|
Koch TARGA II 10072-35 | Torrens 100 | 8 |
Suez ZeeWeed 1500 | 8 | |
Hyflux K600ETI-55 | 7 | |
Veolia, Suez, Zenon or GE ZeeWeed 500D (MBR) | Same size: 2,198 × 844 × 49 mm |
Brand and model names belong to their owners and are used here only to identify the modules each Theway retrofit replaces.
Levels 7 and 8
Theway's eight-level scale describes how closely a retrofit matches the original. Level 8 matches operating philosophy, form and shape, ports, dimensions, membrane material, MWCO, fibre dimensions and performance. Level 7 matches everything except operating philosophy, so we review the cycle settings before start-up. The scale is set out on the direct retrofit page.
When these retrofits make sense
Original modules are hard to source. Plants built around Hyflux modules often struggle to find original spares.
The plant is sound but the membranes are tired. Racks, valves and controls are worth keeping; only the modules have reached the end of their life.
Budget. A retrofit replaces the modules only. New racks and headers are avoided.
In service
Supraflux modules treat river water ahead of RO and the DM plant at a refinery in Eastern India.
Changeover steps
Read the model from the nameplates and photograph the module ends, ports and rack.
Send operating data, cycle settings and cleaning history.
Replace a whole train at a time.
Check couplings and seals.
Flush preservative to drain, vent and ramp flow gradually. See commissioning new UF modules.
Log a day-one baseline of flow, TMP and temperature.
Checklist
Model and quantity confirmed
Photos sent
Cycle settings reviewed for level 7 retrofits
Cleaning chemicals checked against the Theway datasheet
Seals and couplings on site
Baseline planned
Questions buyers ask
Is there a datasheet for Torrens 100?
Yes. Ask for it with your enquiry; it is supplied with the quotation.
Does Surge 500T fit a ZeeWeed 500D cassette?
Surge 500T has the same outer dimensions as the ZeeWeed 500D module (2,198 × 844 × 49 mm) and uses reinforced PVDF with outside-in flow. See replacing ZeeWeed MBR membranes.
My model is not listed. Can you still help?
Often, yes. Send the nameplate details and photos. Theway also makes retrofits for Pentair X-Flow, Hydranautics HYDRAcap and DuPont SFP modules.
Retrofit guides by maker
Get a retrofit quotation
Send model, quantity and photos through Send Enquiry or to mail@thewaymembranes.com.
Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.





Comments