top of page

Replacing IMT UF modules: Theway TN series by model

Nov 15
3 min read

Updated: 8 hours ago

At a glance: Theway's TN series replaces IMT UF modules model for model, from the small 125 laboratory module to the 10060 production modules. Most TN models use seven-bore PES fibre (4.0 mm outside, 0.9 mm bores) filtering in-out, as the IMT UF-MB modules do; TN 10060 SB and SBM are the single-bore equivalents of the UF-SB modules. Each is built to the size and connections of the module it replaces.

Replacing IMT UF modules: Theway TN series by model

Model cross-reference

IMT module in service

Theway replacement

Membrane area

Fibre

IMT 125 UF-MB-TAP

TN 125

0.05 m²

Seven-bore

IMT 225 UF-MB-TAP

TN 225

0.25 m²

Seven-bore

IMT 250 UF-MB-TAP

TN 250

0.6 m²

Seven-bore

IMT 350 UF-MB-TAP

TN 350

1.25 m²

Seven-bore

IMT 475 UF-MB-TAP

TN 475

4.25 m²

Seven-bore

IMT 4100 UF-MB-TAP

TN 4100

5.8 m²

Seven-bore

IMT 4150 UF-MB-TAP

TN 4150

9 m²

Seven-bore

IMT 6100 UF-MB-TAP

TN 6100

12 m²

Seven-bore

IMT 8060 UF-MB-RX

TN 8060

40 m²

Seven-bore

IMT 10060 UF-MB

TN 10060

50 m²

Seven-bore

IMT 10060 UF-MB-G

TN 10060 V

60 m²

Seven-bore

IMT 10060 UF-SB-0.2

TN 10060 SB

35 m²

Single-bore

IMT 10060 UF-SB-2.2

TN 10060 SBM

28 m²

Single-bore

Brand and model names belong to their owners and are used here only to identify the modules each Theway retrofit replaces.

TN data

Parameter

Seven-bore TN models

TN 10060 SB and SBM

Membrane

PES

PES

Fibre

Seven bores, 4.0 mm OD, 0.9 mm bores

Single bore: 2.5 × 1.5 mm (SB), 3.8 × 2.2 mm (SBM)

Flow direction

In-out

In-out

TMP in operation

Below 1.0 bar

Below 1.0 bar

Maximum TMP

2.5 bar

2.5 bar

Backwash and forward flush

250 L/m²·h

250 L/m²·h

Operating pH

3 to 10

3 to 10

Maximum system pressure

10 bar (125 to 6100); 7.5 bar (8060 and 10060)

7.5 bar (SBM); SB on request

Feed flux on the datasheets is 100 to 350 L/m²·h for the small modules and 70 to 120 L/m²·h for the 10060 modules.

Questions buyers ask

Do TN modules work with the existing IMT control sequence?

They are in-out modules with the same fibre type as the modules they replace, so the sequence normally stays. We check your settings against the TN datasheet before start-up.

Is there a replacement for the IMT 125 test module?

Yes, TN 125, with 0.05 m² of membrane, for pilot and laboratory work.

What is the difference between multibore and single-bore fibre?

Multibore fibre carries several bores in one strong body; single-bore fibre has one larger bore. See single-bore vs multi-bore membranes.

Retrofit guides by maker

Get a retrofit quotation

Send the model, the number installed, a photograph of the module ends and recent operating data through Send Enquiry or to mail@thewaymembranes.com. The TN rows in the direct retrofit table link to each datasheet. For what to include, see what data to send with a UF enquiry.

Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.