At a glance: Theway's Mizu series replaces Toray HFU and HFUG pressurised UF modules one for one: HFUG-2020AN with Mizu TW90, HFUG-2020HN with TW90A, HFUG-B2315AN with TW75, HFU-2020AN with TW72, HFU-1020AN with TW29 and HFU-1010N with TW7. Mizu modules use PVDF hollow fibre rated at 0.01 µm, filter out-in in dead-end mode, and are built to the length, diameter and port positions of the module they replace, so the rack, piping and control sequence stay as they are.

Replacing Toray HFU and HFUG UF modules: Theway Mizu by model

Model cross-reference

Toray module in service

Theway replacement

Membrane area

Toray HFUG-2020AN

Mizu TW90

90 m²

Toray HFUG-2020HN

Mizu TW90A

90 m²

Toray HFUG-B2315AN

Mizu TW75

75 m²

Toray HFU-2020AN

Mizu TW72

72 m²

Toray HFU-1020AN

Mizu TW29

29 m²

Toray HFU-1010N

Mizu TW7

On request

Brand and model names belong to their owners and are used here only to identify the modules each Theway retrofit replaces.

Mizu data

Parameter

Mizu series

Membrane

PVDF hollow fibre

Pore size

0.01 µm

Flow direction

Out-in

Operating mode

Dead-end

Housing and caps

uPVC

Potting

Epoxy

Membrane area

29 to 90 m², by model

Mizu TW90 is 2,160 mm long with a 216 mm housing, the same envelope as the HFUG-2020AN. Each model's datasheet gives its drawing, ports and limits.

Before you change over

  • Read the model and quantity from the nameplates and photograph the module ends and rack.

  • Check the cleaning chemicals and cycle settings against the Mizu datasheet limits.

  • Replace a whole train at a time, so every module starts with the same permeability.

  • Flush the preservative to drain before sending filtrate onward. See commissioning new UF modules.

Questions buyers ask

Is Mizu a direct replacement for Toray HFUG-2020AN?

Yes. Mizu TW90 has the same 90 m² of membrane and the same envelope, and fits the existing rack.

Why is the pore size 0.01 µm?

It matches the duty of the Toray modules it replaces. Tighter pores give high rejection of fine particles, bacteria and viruses.

Can Mizu modules run with air scouring?

Yes. They are out-in modules, where air scouring is most effective. See air scouring in UF and MBR membranes.