Replacing Toray HFU and HFUG UF modules: Theway Mizu by model
Updated: 3 hours ago
At a glance: Theway's Mizu series replaces Toray HFU and HFUG pressurised UF modules one for one: HFUG-2020AN with Mizu TW90, HFUG-2020HN with TW90A, HFUG-B2315AN with TW75, HFU-2020AN with TW72, HFU-1020AN with TW29 and HFU-1010N with TW7. Mizu modules use PVDF hollow fibre rated at 0.01 µm, filter out-in in dead-end mode, and are built to the length, diameter and port positions of the module they replace, so the rack, piping and control sequence stay as they are.

Model cross-reference
Toray module in service | Theway replacement | Membrane area |
|---|---|---|
Toray HFUG-2020AN | Mizu TW90 | 90 m² |
Toray HFUG-2020HN | Mizu TW90A | 90 m² |
Toray HFUG-B2315AN | Mizu TW75 | 75 m² |
Toray HFU-2020AN | Mizu TW72 | 72 m² |
Toray HFU-1020AN | Mizu TW29 | 29 m² |
Toray HFU-1010N | Mizu TW7 | On request |
Brand and model names belong to their owners and are used here only to identify the modules each Theway retrofit replaces.
Mizu data
Parameter | Mizu series |
|---|---|
Membrane | PVDF hollow fibre |
Pore size | 0.01 µm |
Flow direction | Out-in |
Operating mode | Dead-end |
Housing and caps | uPVC |
Potting | Epoxy |
Membrane area | 29 to 90 m², by model |
Mizu TW90 is 2,160 mm long with a 216 mm housing, the same envelope as the HFUG-2020AN. Each model's datasheet gives its drawing, ports and limits.
Before you change over
Read the model and quantity from the nameplates and photograph the module ends and rack.
Check the cleaning chemicals and cycle settings against the Mizu datasheet limits.
Replace a whole train at a time, so every module starts with the same permeability.
Flush the preservative to drain before sending filtrate onward. See commissioning new UF modules.
Questions buyers ask
Is Mizu a direct replacement for Toray HFUG-2020AN?
Yes. Mizu TW90 has the same 90 m² of membrane and the same envelope, and fits the existing rack.
Why is the pore size 0.01 µm?
It matches the duty of the Toray modules it replaces. Tighter pores give high rejection of fine particles, bacteria and viruses.
Can Mizu modules run with air scouring?
Yes. They are out-in modules, where air scouring is most effective. See air scouring in UF and MBR membranes.
Retrofit guides by maker
Get a retrofit quotation
Send the model, the number installed, a photograph of the module ends and recent operating data through Send Enquiry or to mail@thewaymembranes.com. The Mizu rows in the direct retrofit table link to each datasheet. For what to include, see what data to send with a UF enquiry.
Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.





Comments