top of page

Replacing DuPont SFP UF modules: Sierra 51 and Sierra 77

Nov 12
3 min read

Updated: 3 hours ago

At a glance: Theway's Sierra 51 (TW 225/1500, 51 m²) replaces the Dow, now DuPont, SFP 2860 module, and Sierra 77 (TW 225/2000, 77 m²) replaces the SFP 2880. Both are equivalence level 8, Theway's closest match, so they fit the existing racks, couplings and pipework and run on the existing control sequence.

Replacing DuPont SFP UF modules: Sierra 51 and Sierra 77

A DuPont replacement in service

Theway UF modules replacing DuPont modules at a thermal power plant
Theway modules in the DuPont positions, thermal power plant, Eastern India

A thermal power plant in Eastern India replaced its DuPont UF modules with 52 Theway TWP 2880 modules in May 2024. The owner certifies at least 90% recovery, filtrate turbidity below 0.1 NTU and SDI below 3. Photos and details.

Model cross-reference

Existing module

Theway retrofit

Area (m²)

Level

SFP 2860

Sierra 51 (TW 225/1500)

51

8

SFP 2880

Sierra 77 (TW 225/2000)

77

8

Brand and model names belong to their owners and are used here only to identify the modules each Theway retrofit replaces.

Sierra specifications

Parameter

Sierra 51

Sierra 77

Membrane

PVDF

PVDF

MWCO

100 kDa

100 kDa

Flow

Out-in

Out-in

Operating mode

Cross flow or dead end

Cross flow or dead end

Feed pressure

3 kg/cm² maximum

3 kg/cm² maximum

Transmembrane pressure

1 kg/cm² maximum

1 kg/cm² maximum

Backwash pressure

2 kg/cm² maximum

2 kg/cm² maximum

pH, cleaning

1 to 13

1 to 13

Temperature

20 to 45 °C

20 to 45 °C

Feed flux

20 to 100 L/m²·h

20 to 100 L/m²·h

Backwash flux

40 to 150 L/m²·h

40 to 150 L/m²·h

Filtration time

15 to 60 min

15 to 60 min

Backwash time

20 to 60 s

20 to 60 s

In service

Sierra modules treat river water at one of India's largest thermal power plants, and Sierra 51 treats sugar process water ahead of RO at a sugar mill in West India.

Changeover steps

  1. Confirm the model from the nameplates: SFP 2860 or SFP 2880.

  2. Send operating data and cleaning history.

  3. Replace a full rack or train, not individual modules.

  4. Inspect couplings and seals and replace worn ones.

  5. Flush preservative to drain, vent air and ramp flow up gradually. See commissioning new UF modules.

  6. Record day-one flow, TMP and temperature.

Checklist

  • Nameplate model and count

  • Rack photos

  • Cycle settings within the Sierra limits above

  • Cleaning chemicals within pH 1 to 13 and 40 °C

  • Spare seals on site

  • Baseline readings planned

Questions buyers ask

Do Sierra modules need different couplings?

No. Level 8 matches ports and dimensions.

Can I keep my CEB and CIP chemicals?

Usually yes, provided pH and temperature stay within the limits above. Send your current recipe and we will check it.

Is there a PVDF option?

Sierra modules are made in PVDF only, the same membrane polymer as the SFP modules they replace.

What does the TW 225 in the model name mean?

It is Theway's internal size code for the Sierra housing and length: TW 225/1500 for Sierra 51 and TW 225/2000 for Sierra 77.

Retrofit guides by maker

Get a retrofit quotation

Send model, quantity and photos through Send Enquiry or to mail@thewaymembranes.com. Other brands are covered on the direct retrofit page.

Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.