Replacing Memcor L10V, L10U and L20V modules: Theway Neptune
Updated: 6 hours ago
At a glance: Theway's Neptune series replaces Memcor L10V, L10U and L20V modules: Neptune NEP 10 for the L10V, NEP 10 Z for the L10U and NEP 20 for the L20V. All three use PVDF hollow fibre rated at 0.04 µm, are cleaned with air scour and liquid backwash, and keep the 119 mm diameter and the length of the module they replace, so they fit existing racks.

Model cross-reference
Memcor module in service | Theway replacement | Membrane area | Length | Diameter |
|---|---|---|---|---|
Memcor L10V | Neptune NEP 10 | 23.4 m² | 1,157 mm | 119 mm |
Memcor L10U | Neptune NEP 10 Z | 18.7 m² | 1,157 mm | 119 mm |
Memcor L20V | Neptune NEP 20 | 38.1 m² | 1,800 mm | 119 mm |
Brand and model names belong to their owners and are used here only to identify the modules each Theway retrofit replaces.
Neptune data
Parameter | Neptune series |
|---|---|
Membrane | PVDF hollow fibre |
Pore size | 0.04 µm |
Flow direction | Out-in (NEP 10 and NEP 20) |
Backwash | Air scour and liquid |
Maximum operating temperature | 45 °C |
Operating pH | 2 to 10 |
Free chlorine | Below 5 ppm on average, 1,000 ppm maximum |
Design flow per module
Typical design flow and recovery from the Neptune datasheets:
Feed water | Neptune NEP 10 | Neptune NEP 20 |
|---|---|---|
Turbid surface water | 30.3 m³/d, 94% | 49.4 m³/d, 94% |
Clear surface water | 38.5 m³/d, 95% | 62.7 m³/d, 96% |
Seawater | 35.7 m³/d, 95% | 58.3 m³/d, 95% |
Secondary effluent | 30.3 m³/d, 93% | 49.4 m³/d, 94% |
Municipal | 55.0 m³/d, over 96% | 89.5 m³/d, over 96% |
NEP 10 Z, with 18.7 m² of membrane, is for high-solids duties: 24.2 m³/d at 93% recovery on turbid surface water.
Questions buyers ask
Which Neptune replaces the Memcor L10V?
Neptune NEP 10: 23.4 m² of membrane in a 119 mm × 1,157 mm module.
Which replaces the L20V?
Neptune NEP 20: 38.1 m² in a 119 mm × 1,800 mm module.
Does Neptune need a different cleaning regime?
No. It runs with the air scour and liquid backwash of the plant it goes into, within the datasheet limits for pH and chlorine.
Retrofit guides by maker
Get a retrofit quotation
Send the model, the number installed, a photograph of the module ends and recent operating data through Send Enquiry or to mail@thewaymembranes.com. The Neptune rows in the direct retrofit table link to each datasheet. For what to include, see what data to send with a UF enquiry.