top of page

Replacing Memcor L10V, L10U and L20V modules: Theway Neptune

Nov 15
2 min read

Updated: 6 hours ago

At a glance: Theway's Neptune series replaces Memcor L10V, L10U and L20V modules: Neptune NEP 10 for the L10V, NEP 10 Z for the L10U and NEP 20 for the L20V. All three use PVDF hollow fibre rated at 0.04 µm, are cleaned with air scour and liquid backwash, and keep the 119 mm diameter and the length of the module they replace, so they fit existing racks.

Replacing Memcor L10V, L10U and L20V modules: Theway Neptune

Model cross-reference

Memcor module in service

Theway replacement

Membrane area

Length

Diameter

Memcor L10V

Neptune NEP 10

23.4 m²

1,157 mm

119 mm

Memcor L10U

Neptune NEP 10 Z

18.7 m²

1,157 mm

119 mm

Memcor L20V

Neptune NEP 20

38.1 m²

1,800 mm

119 mm

Brand and model names belong to their owners and are used here only to identify the modules each Theway retrofit replaces.

Neptune data

Parameter

Neptune series

Membrane

PVDF hollow fibre

Pore size

0.04 µm

Flow direction

Out-in (NEP 10 and NEP 20)

Backwash

Air scour and liquid

Maximum operating temperature

45 °C

Operating pH

2 to 10

Free chlorine

Below 5 ppm on average, 1,000 ppm maximum

Design flow per module

Typical design flow and recovery from the Neptune datasheets:

Feed water

Neptune NEP 10

Neptune NEP 20

Turbid surface water

30.3 m³/d, 94%

49.4 m³/d, 94%

Clear surface water

38.5 m³/d, 95%

62.7 m³/d, 96%

Seawater

35.7 m³/d, 95%

58.3 m³/d, 95%

Secondary effluent

30.3 m³/d, 93%

49.4 m³/d, 94%

Municipal

55.0 m³/d, over 96%

89.5 m³/d, over 96%

NEP 10 Z, with 18.7 m² of membrane, is for high-solids duties: 24.2 m³/d at 93% recovery on turbid surface water.

Questions buyers ask

Which Neptune replaces the Memcor L10V?

Neptune NEP 10: 23.4 m² of membrane in a 119 mm × 1,157 mm module.

Which replaces the L20V?

Neptune NEP 20: 38.1 m² in a 119 mm × 1,800 mm module.

Does Neptune need a different cleaning regime?

No. It runs with the air scour and liquid backwash of the plant it goes into, within the datasheet limits for pH and chlorine.

Retrofit guides by maker

Get a retrofit quotation

Send the model, the number installed, a photograph of the module ends and recent operating data through Send Enquiry or to mail@thewaymembranes.com. The Neptune rows in the direct retrofit table link to each datasheet. For what to include, see what data to send with a UF enquiry.

Specification note: figures are typical values for information only and are not a performance guarantee. Actual performance depends on the feed water, pretreatment and operation. See the product and datasheet disclaimer.

Comments


bottom of page